Spinal Rod Cutter, Item number 00392500200. The product is a nonsterile pin cutter - Product Usage: The intended use of this instrument is to be used for cutting orthopedic rods/pins during orthopedic surgeries.

FDA Recall
Terminated ·Zimmer Biomet, Inc.·Product code HXZ·November 20, 2020

HX2 Temp Manage SYS 120V The Terumo HX2 Temperature Management System is a selfcontained, dual channel system for supplying temperature controlled water to heat exchangers used in an extracorporeal circuit.

FDA Recall
Terminated ·Terumo Cardiovascular Systems Corporation·Product code DWC·October 16, 2012

The Terumo HX2 Temperature Management System provides temperature control of two independent water circuits that directly controls the temperature of patient blood and cardioplegia solution during cardiovascular surgery. The system consists of a water tank, circulating pumps, heater manifolds, mercury free temperature sensors, water detectors, mixing valves and a tank divider which is provided to partition the tank into two separate channels (Left and Right). The system has the capacity to circulate water at a rate of up to 6.5 gal./min (25 L/min) with no load connected. The system is capable of heating and cooling for a single channel or for both channels. Device Name / Model Number: HX2 Temperature Management System (P/N 809810) Catalog Number: 809810

FDA Recall
Terminated ·Terumo Cardiovascular Systems Corporation·Product code DWC·April 16, 2021

Terumo HX2 Temperature Management System, Catalog No. 809810 The Terumo HX2 Temperature Management System is indicated for use to supply temperature regulated water to heat exchangers during open heart surgery.

FDA Recall
Terminated ·Terumo Cardiovascular Systems Corporation·Product code DWC·March 16, 2018

Tested AC Control BD, 120V, X2 The Terumo HX2 Temperature Management System is a selfcontained, dual channel system for supplying temperature controlled water to heat exchangers used in an extracorporeal circuit.

FDA Recall
Terminated ·Terumo Cardiovascular Systems Corporation·Product code DWC·October 16, 2012

HX2" Temperature Management Systems; The Terumo HX2" Temperature Management System provides temperature control of two independent water circuits that directly controls the temperature of patient blood and cardioplegia solution during cardiovascular surgery. The system consists of a water tank, circulating pumps, heater manifolds, mercury free temperature sensors, water detectors, mixing valves and a tank divider which is provided to partition the tank into two separate channels (Left and Right).The system has the capacity to circulate water at a rate of up to 6.5 gal.min (25 L/min) with no load connected. The system is capable of heating and cooling for a single channel or for both channels. Product Usage: HX2 Temperature Management Systems is indicated for use to supply temperature regulated water to heat exchangers during open heart surgery.

FDA Recall
Terminated ·Terumo Cardiovascular Systems Corporation·Product code DWC·June 8, 2016

Terumo HX2 Temperature Management System 120V, 50/60 Hz catalog number 809810, Terumo Cardiovascular Systems Corp., Ann Arbor MI. The Terumo HX2 Temperature Management System provides temperature control of two independent water circuits that directly control the temperature of the patients blood and cardioplegia solution during cardiovascular bypass surgery. The system consists of a water tank, circulating pumps, heater manifolds, mercury free temperature sensors, water detectors, mixing valves and a tank divider which is provided to partition the tank into two separate channels.

FDA Recall
Terminated ·Terumo Cardiovascular Systems Corporation·Product code DWC·June 11, 2010

The Sarns Temperature Control and Monitor unit (TCM) is a source of temperature-controlled water for blood heat exchangers used in an extracorporeal circuit and for blankets to externally heat or cool the patient. The TCM with options will also supply water for cardioplegia, freeze water for an ice supply, monitor temperatures in the patient and extracorporeal circuit, and allow gradient rewarming relative to a venous blood temperature. Device Name / Model Number: TCM II TUV, 115V (P/N 4415), TCM II TUV, 220V (P/N 4416), Catalog Number: 4416, 164940

FDA Recall
Terminated ·Terumo Cardiovascular Systems Corporation·Product code DWC·April 16, 2021

The Sarns TCM II (system) is a source of temperature-controlled water for blood heat exchangers used in an extracorporeal circuit and for blankets to externally heat or cool the patient. It also freezes water for an ice supply, monitors temperatures in the patient and extracorporeal circuit, and allows gradient rewarming relative to a venous blood temperature. The Sarns" TCM II also features a Cardioplegia System which will supply cooling water for cardioplegia. Device Name / Model Number: TCM II, with Cardioplegia, 110V/60Hz (P/N 164925) TCM II, without Cardioplegia, 110V/60Hz (P/N 164930) TCM II, with Cardioplegia, 220V/50Hz (P/N 164935) TCM II, without Cardioplegia, 220V/50Hz (P/N 164940) TCM (P/N 15747) Catalog Number: 4415, 164925, 164930, 164935, 15747

FDA Recall
Terminated ·Terumo Cardiovascular Systems Corporation·Product code DWC·April 16, 2021

Terumo HX2 Temperature Management System provides temperature control of two independent water circuits that directly controls the temperature of patient blood and cardioplegia solution during cardiovascular surgery.

FDA Recall
Terminated ·Terumo Cardiovascular Systems Corporation·Product code DWC·February 6, 2015

Sarns TCM; The Sarns Temperature Control and Monitor unit (TCM) is a source of temperature-controlled water for blood heat exchangers used in an extracorporeal circuit and for blankets to externally heat or cool the patient The TCM with options will also supply water for cardioplegia, freeze water for an ice supply, monitor temperatures in the patient and extracorporeal circuit, and allow gradient rewarming relative to a venous blood temperature. Product Usage: The Sarns TCM is indicated for controlling and monitoring patient temperature.

FDA Recall
Terminated ·Terumo Cardiovascular Systems Corporation·Product code DWC·June 8, 2016

Sarns TCM II; The Sarns Temperature Control and Monitor unit (TCM) II (system) is a source of temperature controlled water for blood heat exchangers used in an extracorporeal circuit and for blankets to externally heat or cool the patient. It also freezes water for an ice supply, monitors temperatures in the patient and extracorporeal circuit, and allows gradient rewarming relative to a venous blood temperature. Product Usage: The Sarns TCM II is indicated for controlling and monitoring patient temperature.

FDA Recall
Terminated ·Terumo Cardiovascular Systems Corporation·Product code DWC·June 8, 2016

EZ Derm Porcine Xenograft, labeled as the following: a. EZ Derm 3x4 (8x10 cm) Non-Perforated, Part Number: 131703-03; b. EZ Derm 7 x 18 (17 x 46 cm) Non-Perforated, Part Number: 131704-03; c. EZ Derm 2 x 2 (5 x 5 cm) Non-Perforated, Part Number: 131705-03; d. EZ Derm 3 x 48 (8 x 122 cm) Perforated, Part Number: 131710-03; e. EZ Derm 3 x 24 (8 x 61 cm) Perforated, Part Number: 131711-03; f. EZ Derm 3 x 12 (8 x 30 cm) Perforated, Part Number: 131712-03; g. EZ Derm 3 x 4 (8 x 10 cm) Perforated, Part Number: 131713-03; h. EZ Derm 7 x 18 (17 x 46 cm) Perforated, Part Number: 131714-03; i. EZ Derm 2 x 2 (5 x 5 cm) Perforated. Part Number: 131715-03 Product Usage: EZ Derm is a porcine derived xenograft in which the collagen has been cross linked with an aldehyde. EZ Derm (porcine xenograft) can be used for partial thickness skin loss injuries. Use of EZ Derm for burns, donor sites and chronic vascular ulcers reduces pain and fluid loss. EZ Derm can also be used as a temporary cover, or test graft, prior to auto grafting and as a protective covering over perforated auto grafts.

FDA Recall
Terminated ·Molnlycke Health Care, Inc·Product code KGN·March 26, 2019

Preamendments device-Sarns Dual Cooler-Heater. The Sarns Dual Cooler-Heater is a self-contained unit for supplying cold and warm water to heat exchangers during open heart surgery. It supplies water at a rate of up to 6.5 gallons per minute (25 liters per minute) at zero head, and will provide a maximum pressure output of 11 pounds per square inch (76,000 pascals). The Sarns TM Dual Cooler-Heater can be used with heat exchangers capable of accepting these flows and pressures. Product Usage: The Sarns Dual Cooler-Heater is indicated for use as a water supply system to a blood heat exchanger in open-heart surgery.

FDA Recall
Terminated ·Terumo Cardiovascular Systems Corporation·Product code DWC·June 8, 2016

17G x 90m Tuohy Stimulation Catheter Kit, REF 553-218-90, Rx, Sterile, Distributed by: Stryker Instruments, Kalamazoo, MI.

FDA Recall
Terminated ·Stryker Instruments Div. of Stryker Corporation·Product code GXZ·February 1, 2010

24G x 25mm/45 Bevel Single Shot Needle, REF 554-024-025, Rx, Sterile, Distributed by: Stryker Instruments, Kalamazoo, MI.

FDA Recall
Terminated ·Stryker Instruments Div. of Stryker Corporation·Product code GXZ·February 1, 2010

Disposable Subdermal Needle Electrode, Corkscrew, Single Use, Sterile; Model Numbers TE/S50715-001-C, TE/S50725-001C, and TE/S50715-001.

FDA Recall
Terminated ·Technomed Europe Amerikalaan 71 Maastricht-Airport Netherlands·Product code GXZ·December 8, 2021

CryoPatch SG Pulmonary Human Cardiac Patch. The patch is cryopreserved in a tissue culture medium containing cryoprotectants within the innermost pouch of a three-pouch packaging system. The packaging system not only withstands ultracold temperatures, but also allows for aseptic introduction of the patch into the operating environment. Supercooling by liquid nitrogen boost is begun prior to crystallization to minimize ice crystal damage to the patch matrix. Finally, the patch is transferred for long-term storage at or below 135 C. CryoPatch SG is distributed in three anatomic configurations: pulmonary hemi-artery, pulmonary trunk and pulmonary branch.

FDA Recall
Terminated ·CryoLife, Inc.·Product code DXZ·November 10, 2020

22G x 50m/20 bevel Single Shot Needle, REF 552-022-050, Rx, Sterile, Distributed by: Stryker Instruments, Kalamazoo, MI.

FDA Recall
Terminated ·Stryker Instruments Div. of Stryker Corporation·Product code GXZ·February 1, 2010

18G x 50mm/20 Tuohy Catheter Kit, REF 553-118-050, Rx, Sterile, Distributed by: Stryker Instruments, Kalamazoo, MI.

FDA Recall
Terminated ·Stryker Instruments Div. of Stryker Corporation·Product code GXZ·February 1, 2010