Terumo HX2 Temperature Management System provides temperature control of two independent water circuits that directly controls the temperature of patient blood and cardioplegia solution during cardiovascular surgery.

FDA Enforcement
Class II ·Terminated·Terumo Cardiovascular Systems Corporation·February 25, 2015

HX2 Temp Manage SYS 120V The Terumo HX2 Temperature Management System is a selfcontained, dual channel system for supplying temperature controlled water to heat exchangers used in an extracorporeal circuit.

FDA Enforcement
Class II ·Terminated·Terumo Cardiovascular Systems Corporation·November 21, 2012

HX2" Temperature Management Systems; The Terumo¿ HX2" Temperature Management System provides temperature control of two independent water circuits that directly controls the temperature of patient blood and cardioplegia solution during cardiovascular surgery. The system consists of a water tank, circulating pumps, heater manifolds, mercury free temperature sensors, water detectors, mixing valves and a tank divider which is provided to partition the tank into two separate channels (Left and Right).The system has the capacity to circulate water at a rate of up to 6.5 gal.min (25 L/min) with no load connected. The system is capable of heating and cooling for a single channel or for both channels. Product Usage: HX2 Temperature Management Systems is indicated for use to supply temperature regulated water to heat exchangers during open heart surgery.

FDA Enforcement
Class II ·Terminated·Terumo Cardiovascular Systems Corporation·July 27, 2016

Tested AC Control BD, 120V, X2 The Terumo HX2 Temperature Management System is a selfcontained, dual channel system for supplying temperature controlled water to heat exchangers used in an extracorporeal circuit.

FDA Enforcement
Class II ·Terminated·Terumo Cardiovascular Systems Corporation·November 21, 2012

Terumo HX2 Temperature Management System, Catalog No. 809810 The Terumo HX2 Temperature Management System is indicated for use to supply temperature regulated water to heat exchangers during open heart surgery.

FDA Enforcement
Class II ·Terminated·Terumo Cardiovascular Systems Corporation·April 25, 2018

The Terumo HX2 Temperature Management System provides temperature control of two independent water circuits that directly controls the temperature of patient blood and cardioplegia solution during cardiovascular surgery. The system consists of a water tank, circulating pumps, heater manifolds, mercury free temperature sensors, water detectors, mixing valves and a tank divider which is provided to partition the tank into two separate channels (Left and Right). The system has the capacity to circulate water at a rate of up to 6.5 gal./min (25 L/min) with no load connected. The system is capable of heating and cooling for a single channel or for both channels. Device Name / Model Number: HX2 Temperature Management System (P/N 809810) Catalog Number: 809810

FDA Enforcement
Class II ·Terminated·Terumo Cardiovascular Systems Corporation·June 9, 2021

Zebra Thermal Barcode Printer GX430t, Model no. YSW 1000 or YSW 2000, may have been sold as an optional accessory for Sensititre Aris HIQ system YV4000-VZ

FDA Enforcement
Class II ·Ongoing·Remel, Inc·March 26, 2025

Alinity h Interface Module (HSQ)-Laboratory Automation system Brand names of the same product: FlexLab (FLX), Accelerator a3600 (ACP), Aptio Automation (AP2) Part Numbers: FLX-274-20

FDA Enforcement
Class II ·Ongoing·Inpeco S.A.·May 10, 2023

The Sarns Temperature Control and Monitor unit (TCM) is a source of temperature-controlled water for blood heat exchangers used in an extracorporeal circuit and for blankets to externally heat or cool the patient. The TCM with options will also supply water for cardioplegia, freeze water for an ice supply, monitor temperatures in the patient and extracorporeal circuit, and allow gradient rewarming relative to a venous blood temperature. Device Name / Model Number: TCM II TUV, 115V (P/N 4415), TCM II TUV, 220V (P/N 4416), Catalog Number: 4416, 164940

FDA Enforcement
Class II ·Terminated·Terumo Cardiovascular Systems Corporation·June 9, 2021

Accelerator a3600 Automation System used with the following Modules: High Volume Storage(P/N FLX-270, FLX-271, FLX-276, FLX-282, FLX-283), HSQ Interface Module (P/N FLX-274), Aliquoter Module (P/N FLX-209), Rack Output Module ROM400 (P/N FLX-289), XN-9000 Interface Module (P/N FLX-290), Advia 2120 LAS Interface Module (P/N FLX-219), Vertical Transportation Module (P/N FLX -204), Rack Input Module (P/N FLX-214), AUWi System Interface Module (P/N FLX-286), Track To Rack Interface Module (P/N FLX-295) - Product Usage: is a modular system designed to automate Pre-Analytical and Post-Analytical processing, sample handling in order to automate sample processing in the Laboratory. The systems consolidate multiple Analytical instruments into a unified workstation.

FDA Enforcement
Class II ·Terminated·Inpeco S.A.·June 3, 2020

The Sarns TCM II (system) is a source of temperature-controlled water for blood heat exchangers used in an extracorporeal circuit and for blankets to externally heat or cool the patient. It also freezes water for an ice supply, monitors temperatures in the patient and extracorporeal circuit, and allows gradient rewarming relative to a venous blood temperature. The Sarns" TCM II also features a Cardioplegia System which will supply cooling water for cardioplegia. Device Name / Model Number: TCM II, with Cardioplegia, 110V/60Hz (P/N 164925) TCM II, without Cardioplegia, 110V/60Hz (P/N 164930) TCM II, with Cardioplegia, 220V/50Hz (P/N 164935) TCM II, without Cardioplegia, 220V/50Hz (P/N 164940) TCM (P/N 15747) Catalog Number: 4415, 164925, 164930, 164935, 15747

FDA Enforcement
Class II ·Terminated·Terumo Cardiovascular Systems Corporation·June 9, 2021

FlexLab Automation System used with the following Modules: High Volume Storage(P/N FLX-270, FLX-271, FLX-276, FLX-282, FLX-283), HSQ Interface Module (P/N FLX-274), Aliquoter Module (P/N FLX-209), Rack Output Module ROM400 (P/N FLX-289), XN-9000 Interface Module (P/N FLX-290), Advia 2120 LAS Interface Module (P/N FLX-219), Vertical Transportation Module (P/N FLX -204), Rack Input Module (P/N FLX-214), AUWi System Interface Module (P/N FLX-286), Track To Rack Interface Module (P/N FLX-295) - Product Usage: is a modular system designed to automate Pre-Analytical and Post-Analytical processing, sample handling in order to automate sample processing in the Laboratory. The systems consolidate multiple Analytical instruments into a unified workstation.

FDA Enforcement
Class II ·Terminated·Inpeco S.A.·June 3, 2020

Synthes External Fixation System Tube to Tube Clamp, Part Number 390.007. Intended for use to provide treatment for long bone and pelvic fractures that require external fixation. Specifically, the components can be used for: Stabilization of soft tissues and fractures; Polytrauma/multiple orthopedic trauma; Vertically stable pelvic fractures, or as treatment adjunct for vertically unstable pelvic fractures; Arthrodeses and osteotomies with soft tissue problems - failures of total joints; Neutralization of fractures stabilized with limited internal fixation; Non-unions/septic non-unions; Intra-operative reductions/stabilization tool to assist with indirect reduction; and Unilateral rectilinear bone segment transport or leg lengthening.

FDA Enforcement
Class II ·Terminated·Synthes USA HQ, Inc.·November 21, 2012

Synthes Titanium Trochanteric Fixation Nail (TFN)-Helical Blade Synthes Titanium Trochanteric Fixation Nail (TFN)-Helical Blade is used to treat stable and unstable fractures of the proximal femur including pertrochanteric fractures, intertrochanteric fractures, basal neck fractures, and combinations thereof. The long TFN is additionally indicated for subtrochanteric fractures, pertrochanteric fractures associated with shaft fractures, pathologic fractures (including prophylactic use) in both trochanteric and diaphyseal regions, long subtrochanteric fractures, proximal or distal non-unions, malunions, and revisions.

FDA Enforcement
Class II ·Terminated·Synthes USA HQ, Inc.·November 27, 2013

Synthes Trauma Nail System. The devices are indication for bone fixation.

FDA Enforcement
Class II ·Terminated·Synthes USA HQ, Inc.·September 4, 2013

Flexible Grip which is part of the Synthes Universal Nail System. Indicated for the conventional (non-locking) technique of treating stable diaphyseal fractures.

FDA Enforcement
Class II ·Terminated·Synthes USA HQ, Inc.·April 17, 2013

4.5mm TI Multiloc Screw Length 38MM-Sterile Expiration: 04/29/2012 REF 04.019.038S Manufactured or Distributed by Synthes (USA) 1101 Synthes Avenue, Monument CO 80132 4.5MM TI Multiloc Screw Length 38MM-Sterile Ref 04.019,038S. The Multiloc Screw 4.5 is used with a Multiloc PHN for treatment of proximal humerus fractures and is intended to be inserted through the Multiloc PHN until it engages the subchondral bone below the relative distal cortex (cortex closest to the humeral head, below the articular surface).

FDA Enforcement
Class II ·Terminated·Synthes USA HQ, Inc.·August 1, 2012

Synthes Trochanteric Fixation Nail As part of the Synthes Trochanteric Fixation Nail (TFN) System, the TFN Nail is intended to treat stable and unstable fractures of the proximal femur.

FDA Enforcement
Class II ·Terminated·Synthes USA HQ, Inc.·December 18, 2013

Synthes Soft Tissue Retractor Small Extendible Offset blade facilitates easy preparation of the epipereosteal cavity for percutaneous plate insertion.

FDA Enforcement
Class II ·Terminated·Synthes USA HQ, Inc.·November 27, 2013

4.5mm TI Multiloc Screw Length 28MM-Sterile Expiration: 04/29/2012 REF 04.019.028S Manufactured or Distributed by Synthes (USA) 1101 Synthes Avenue, Monument CO 80132 4.5MM TI Multiloc Screw Length 28MM-Sterile Ref 04.019,038S. The Multiloc Screw 4.5 is used with a Multiloc PHN for treatment of proximal humerus fractures and is intended to be inserted through the Multiloc PHN until it engages the subchondral bone below the relative distal cortex (cortex closest to the humeral head, below the articular surface).

FDA Enforcement
Class II ·Terminated·Synthes USA HQ, Inc.·August 1, 2012