38 results · 9ms · Sources: EU EUDAMED, US FDA

Get notified when this changes

We'll email you when new records match this search — new devices, new clearances, certificate changes, or withdrawals.

The following first aid kits and cabinets containing components Medi-First XS Non-Aspirin, Product #80450, 2 tablets/packet, 25 packets/box; and Sinus Pain & Pressure, Product #81950, 2 tablets/packet, 25 packets/box. Product number and description: (1) K614-020 16PW - Firestone Supplemental - w/Logo; (2) KR614-020 16R - Firestone Supplemental - Refill; (3) K616-033 36M - Class A Office - Metal; (4) KR616-006 36R - Class A Office - Refill; (5) KR616-015 75R - Class A Office - Refill; (6) K616-015 75V - Class A Office - 3-Shelf Cabinet; (7) K618-016 EMT - Duke Energy TD - Red Bag; (8) KR618-016 EMTR - Duke Energy TD - Refill; (9) K616-008 FAC-3 - Class B + Meds - 3 Shelf Cabinet; (10) KR616-008 FAC-3R - Class B + Meds - Refill; (11) K618-013 FAC-3 - Five Star Safety - w/Logo; (12) K611-044 FAC-3 - Uline 100 person - w/Logo; (13) K620-609 FAC-3 - Uline Class B + Meds - w/Logo; (14) K616-072 FAC-4 - Choate Construction - w/Logo; (15) KR616-072 FAC-4R - Choate Construction - Refill; (16) K616-066 FAC-4 - Class B + Meds - 4 Shelf Cabinet; (17) KR616-066 FAC-4R - Class B + Meds - Refill; (18) K612-159 FAC-4 - Uline - w/Logo - w/Contents sticker; (19) K616-067 FAC-5 - Class B - 5 Shelf Cabinet; (20 KR616-067 FAC-5R - Class B - Refill

FDA Enforcement
Class II ·Ongoing·Certified Safety Mfg Inc·May 18, 2022

BD FACS 7-color Setup beads BD Biosciences, San Jose, CA 95131. BD FACS 7 color Setup Beads are for in vitro diagnostic use on BD FACSCanto or BD FACSCanto II systems. The beads are run with BD FACSCanto clinical software. This system provides application specific setup, including automated compensation and cytometer quality control (QC) with minimal user intervention.

FDA Enforcement
Class II ·Terminated·BD Biosciences, Systems & Reagents·September 26, 2012

BD FACS Sample Prep Assistant (SPA) II - Product Usage: K050191: The BD FACSCanto system with BD FACSCanto clinical software when used with the BD FACS Sample Prep Assistant II /III is intended for use as an in vitro diagnostic device for identification and enumeration of lymphocyte subsets in human cells in suspension using a lyse / no-wash sample preparation method for flow cytometry.

FDA Enforcement
Class II ·Terminated·Becton, Dickinson and Company, BD Biosciences·June 17, 2020

First aid/emergency kits containing Honeywell eyewash: CSM kit number Kit/cabinet Description CSM Eyewash# Size: Honeywell Part# K206125 LXXV - 75V " Economy Cabinet 3 Shelf R508016 Eye Wash " 4 oz. 32-000452-0000 K 206154 LXXV - 75V " Deluxe Cabinet ¿3 Shelf RS08016 Eye Wash - 4 oz. 32-000452-0000 K206210 FAC- 3 ¿Deluxe Cabinet ¿3 Shelf R508016 Eye Wash - 4 oz. 32-000452-0000 K606999 ZLB¿CSX CPR Kit 37 R508016 Eye Wash " 4 oz. 32-000452-0000 KR206152 FAC " 4R ¿200 Person Deluxe Cabinet - Refill R508016 Eye Wash ¿4 oz. 32-000452-0000 K608054 Cement Burn Cabinet R511018 Eye Wash " 16 oz. 32-000454 0000- H5 K610045 FAC.3 " Deluxe Cabinet .w/BBP .NO MEDS .3 Shelf R508016 Eye Wash " 4 oz. 32-000452-0000 K606289 Eye Wash Cabinet ¿316 R511018 Eye Wash - 16oz 32-000454-0000-HS K608061 36M¿Delmarva Power/ACE¿w/Logo R508016 Eye Wash¿4 oz. 32-000452-0000 K611017 16PW " Hospeco " w/logo R508016 Eye Wash " 4 oz. 32-000452-0000 K206152 FAC¿4 ¿200 Person Deluxe Cabinet ¿4 Shelf R508016 Eye Wash¿4 oz. 32-000452-0000 K206140 CLX ¿100 Person ¿Deluxe Cabinet " 3 Shelf R508016 Eye Wash " 4 oz. 32-000452-0000 KR206210 FAC " 3R " Deluxe Cabinet ¿Refill R508016 Eye Wash " 4 oz 32-000452-0000 K209061 TRMK ¿Trauma Kit with Orange Co-Polymer Case R511018 Eye Wash -16 oz. 32-000454-0000-HS K206130 LXXV¿7SH¿Standard Cabinet Swing Out Door¿2 Shelf R508016 Eye Wash " 4 oz 32-000452-0000 Product Usage: various first aid/emergency kits containing eyewash

FDA Enforcement
Class II ·Terminated·Certified Safety Mfg Inc·April 18, 2018

Atrapro Antipruritic Hydrogel, 1.5 oz gel tube, 4 Net wt/ 1.5 oz.. RX only, Professional Sample, Not for Sale. Pre-printed tube: MS31071, Shelf carton: PL51091-08 Atrapro Antipruritic HydroGel is indicated to manage and relieve the burning, itching and pain experienced with various types of dermatoses, including radiation dermatitis and atopic dermatitis.

FDA Enforcement
Class II ·Terminated·Oculus Innovative Sciences Inc·March 6, 2013

BD FACS Canto and associated Fluidics Cart Product Usage: Flow cytometer for use in In vitro Diagnostics.

FDA Enforcement
Class II ·Terminated·BD Biosciences, Systems & Reagents·July 9, 2014

BD FACS Sample Prep Assistant (SPA) II Upgrade - Product Usage: K050191: The BD FACSCanto system with BD FACSCanto clinical software when used with the BD FACS Sample Prep Assistant II /III is intended for use as an in vitro diagnostic device for identification and enumeration of lymphocyte subsets in human cells in suspension using a lyse / no-wash sample preparation method for flow cytometry.

FDA Enforcement
Class II ·Terminated·Becton, Dickinson and Company, BD Biosciences·June 17, 2020

REF: 666289 , BD FACS, 7-Color Setup Beads, 25 Runs, CE, IVD. Used in flow cytometry for fluorescence compensation.

FDA Enforcement
Class II ·Ongoing·Becton, Dickinson and Company, BD Bio Sciences·July 9, 2025

REF: 335775 , BD FACS, 7-Color Setup Beads, 25 setups per kit, Rx Only, IVD. Used in flow cytometry for fluorescence compensation.

FDA Enforcement
Class II ·Ongoing·Becton, Dickinson and Company, BD Bio Sciences·July 9, 2025

Ziehm Vision(2) FD C-Arm Interventional Fluoroscopic X-Ray System. Mobile Fluoroscopic Imaging

FDA Enforcement
Class II ·Terminated·Ziehm Imaging Inc·January 1, 2014

FACSLyric 3L8C Instrument US-IVD, Catalog Number 662877, UDI 00382906628770 The K170974 clearance document describes the device as follows: The BD FACSLyric" flow cytometer (3-1, 4-2, 4-2-2, and 4-3-3 optical configurations) systems consist of a flow cytometer, sheath tank, waste tank, and a computer workstation. System options include an automated FACS Universal Loader and a barcode reader. The BD FACSLyric Flow Cytometer includes the 488 nm laser and 640 nm laser as part of four available manufactured instrument configurations. BD FACSLyric Flow Cytometer, 3-1 configuration, 4-color/2-laser BD FACSLyric Flow Cytometer, 4-2 configuration, 6-color/2-laser BD FACSLyric Flow Cytometer, 4-2-2 configuration, 8-color/3-laser BD FACSLyric Flow Cytometer, 4-3-3 configuration, 10-color/3-laser The lower level configurations are upgradeable to higher level configurations by adding filters, photomultiplier tubes (PMTs), and a laser. Only the 488 nm laser and 640 nm lasers are utilized for cleared in vitro diagnostic (IVD) applications and only fluorescence channels 1 (FL1) through FL6 are the subject of this 510(k) submission. Seven to tencolor immunophenotyping is for research use only (RUO). All optical configurations of the FACSLyric share the same dimensions: 22.8 inches in height by 24.93 inches in width by 22.8 inches in depth. The K201814 clearance document describes the device as follows: Refer to K170974 for detailed description and functioning of the BD FACSLyric flow cytometer. The modified BD FACSLyric Flow Cytometer consists of the following components. " FACSLyric Flow Cytometer (3-1, 4-2, 4-2-2 ,4-3-3 and 4-3-5 optical configurations) " FACSuite Clinical Software (version 1.4) " Modified FACS Universal Loader: updated shaker and modification to the door lock and sensor connections " Modified CMS firmware BD FACSLyric Flow Cytometer with the integrated BD FACSDuet Sample Preparation system consists of all the above components as FACSLyric Flow Cytometer and additionally contain: " BD FACSDuet Sample Preparation system physically and data integrated with the BD FACSLyric Flow Cytometer " FACSDuet fluidics that contain saline, deionized (DI) water and 10% bleach solution. " Modified FACS Universal Loader: updated shaker, modification to the door lock and sensor connections, addition of stabilization bracket

FDA Enforcement
Class II ·Ongoing·Becton, Dickinson and Company, BD Bio Sciences·January 1, 2025

BD Trucount Absolute Counting Tubes: Model number: 340334 IVD; BD Trucount tubes are used for determining absolute counts of leucocytes in blood. BD Trucount tubes are designed for use with in vitro diagnostic products such as BD Tritest reagents, and a suitably equipped flow cytometer. BD Trucount tubes can be used with the BD FACS Loader.

FDA Enforcement
Class II ·Terminated·Becton, Dickinson and Company, BD Biosciences·May 4, 2016

Fuse 1C Colonoscope

FDA Enforcement
Class II ·Terminated·EndoChoice, Inc.·February 3, 2016

Analyte specific reagent. REF/UDI: 641408/641408-4012-1-1 (US); 641417/641417-1157-1-01 (OUS); 641399/641399-4012-1-01 (US Research Use Only) - Product Usage: CD45 is intended for in vitro diagnostic use in the identification of cells expressing the CD45 antigen, using a BD FAC brand flow cytometer. The flow cytometer must be equipped to detect light scatter and the appropriate fluorescence, and be equipped with appropriate software (such as BD CellQuest, BD CellQuest Pro, BD FACSDiva, or BD FACSCanto clinical software) for data acquisition and analysis.

FDA Enforcement
Class II ·Terminated·Becton, Dickinson and Company, BD Biosciences·May 20, 2020

BD FACS Sample Prep Assistant (SPA) III - Product Usage: Prep Assistant III is intended to prepare human whole blood for flow cytometric analysis on BD FACSCanto II and BD FACSCalibur flow cytometry systems. Pipetting blood, reagents, and lysing solution using the following previously cleared assays for flow cytometric analysis on BD FACSCanto II flow cytometry systems

FDA Enforcement
Class II ·Terminated·Becton, Dickinson and Company, BD Biosciences·June 17, 2020

Device Description: FACSLyric 2L6C Instrument US, Catalog Number 662876, UDI 00382906628763 The K170974 clearance document describes the device as follows: The BD FACSLyric" flow cytometer (3-1, 4-2, 4-2-2, and 4-3-3 optical configurations) systems consist of a flow cytometer, sheath tank, waste tank, and a computer workstation. System options include an automated FACS Universal Loader and a barcode reader. The BD FACSLyric Flow Cytometer includes the 488 nm laser and 640 nm laser as part of four available manufactured instrument configurations. BD FACSLyric Flow Cytometer, 3-1 configuration, 4-color/2-laser BD FACSLyric Flow Cytometer, 4-2 configuration, 6-color/2-laser BD FACSLyric Flow Cytometer, 4-2-2 configuration, 8-color/3-laser BD FACSLyric Flow Cytometer, 4-3-3 configuration, 10-color/3-laser The lower level configurations are upgradeable to higher level configurations by adding filters, photomultiplier tubes (PMTs), and a laser. Only the 488 nm laser and 640 nm lasers are utilized for cleared in vitro diagnostic (IVD) applications and only fluorescence channels 1 (FL1) through FL6 are the subject of this 510(k) submission. Seven to tencolor immunophenotyping is for research use only (RUO). All optical configurations of the FACSLyric share the same dimensions: 22.8 inches in height by 24.93 inches in width by 22.8 inches in depth. The K201814 clearance document describes the device as follows: Refer to K170974 for detailed description and functioning of the BD FACSLyric flow cytometer. The modified BD FACSLyric Flow Cytometer consists of the following components. " FACSLyric Flow Cytometer (3-1, 4-2, 4-2-2 ,4-3-3 and 4-3-5 optical configurations) " FACSuite Clinical Software (version 1.4) " Modified FACS Universal Loader: updated shaker and modification to the door lock and sensor connections " Modified CMS firmware BD FACSLyric Flow Cytometer with the integrated BD FACSDuet Sample Preparation system consists of all the above components as FACSLyric Flow Cytometer and additionally contain: " BD FACSDuet Sample Preparation system physically and data integrated with the BD FACSLyric Flow Cytometer " FACSDuet fluidics that contain saline, deionized (DI) water and 10% bleach solution. " Modified FACS Universal Loader: updated shaker, modification to the door lock and sensor connections, addition of stabilization bracket

FDA Enforcement
Class II ·Ongoing·Becton, Dickinson and Company, BD Bio Sciences·January 1, 2025

FACSLyric 3L10C Instrument US-IVD, Catalog Number 662878, UDI 00382906628787 The K170974 clearance document describes the device as follows: The BD FACSLyric" flow cytometer (3-1, 4-2, 4-2-2, and 4-3-3 optical configurations) systems consist of a flow cytometer, sheath tank, waste tank, and a computer workstation. System options include an automated FACS Universal Loader and a barcode reader. The BD FACSLyric Flow Cytometer includes the 488 nm laser and 640 nm laser as part of four available manufactured instrument configurations. BD FACSLyric Flow Cytometer, 3-1 configuration, 4-color/2-laser BD FACSLyric Flow Cytometer, 4-2 configuration, 6-color/2-laser BD FACSLyric Flow Cytometer, 4-2-2 configuration, 8-color/3-laser BD FACSLyric Flow Cytometer, 4-3-3 configuration, 10-color/3-laser The lower level configurations are upgradeable to higher level configurations by adding filters, photomultiplier tubes (PMTs), and a laser. Only the 488 nm laser and 640 nm lasers are utilized for cleared in vitro diagnostic (IVD) applications and only fluorescence channels 1 (FL1) through FL6 are the subject of this 510(k) submission. Seven to tencolor immunophenotyping is for research use only (RUO). All optical configurations of the FACSLyric share the same dimensions: 22.8 inches in height by 24.93 inches in width by 22.8 inches in depth. The K201814 clearance document describes the device as follows: Refer to K170974 for detailed description and functioning of the BD FACSLyric flow cytometer. The modified BD FACSLyric Flow Cytometer consists of the following components. " FACSLyric Flow Cytometer (3-1, 4-2, 4-2-2 ,4-3-3 and 4-3-5 optical configurations) " FACSuite Clinical Software (version 1.4) " Modified FACS Universal Loader: updated shaker and modification to the door lock and sensor connections " Modified CMS firmware BD FACSLyric Flow Cytometer with the integrated BD FACSDuet Sample Preparation system consists of all the above components as FACSLyric Flow Cytometer and additionally contain: " BD FACSDuet Sample Preparation system physically and data integrated with the BD FACSLyric Flow Cytometer " FACSDuet fluidics that contain saline, deionized (DI) water and 10% bleach solution. " Modified FACS Universal Loader: updated shaker, modification to the door lock and sensor connections, addition of stabilization bracket

FDA Enforcement
Class II ·Ongoing·Becton, Dickinson and Company, BD Bio Sciences·January 1, 2025

BD Trucount Tubes (Cat. No. 663028), used for determining absolute counts of leukocytes in blood. BD Trucount Tubes are designed for use with in vitro diagnostic products such as BD Tritest reagents, and a suitably equipped flow cytometer. BD Trucount Tubes can be used with the BD FACS Loader.

FDA Enforcement
Class II ·Ongoing·Becton, Dickinson and Company, BD Biosciences·November 9, 2022

BD Trucount Tubes (Cat. No. 340334), used for determining absolute counts of leucocytes in blood. BD Trucount tubes are designed for use with in vitro diagnostic products such as BD Tritest reagents, and a suitably equipped flow cytometer. BD Trucount tubes can be used with the BD FACS Loader.

FDA Enforcement
Class II ·Ongoing·Becton, Dickinson and Company, BD Biosciences·November 9, 2022

microTargeting" Drive System, Product Number MT-DS-01

FDA Enforcement
Class II ·Terminated·FHC, Inc.·July 11, 2018