16 results
·
28ms
·
Sources: EU EUDAMED, US FDA
Filters
Status: Terminated
×
TRx4841A 1.4 GHz IntelliVue Tele TRX, Model Number 862439; Includes System Codes 453564007261, 453564007271, 453564007281, 989803196951
FDA Recall
Terminated
·Philips North America, LLC·Product code MHX·March 5, 2020
TRx4851A 2.4 GHz IntelliVue Tele TRX, Model Number 862231; Includes Service Numbers 453564052401, 453564052411, 453564052441, 453564052451, 453564166851, 453564166861
FDA Recall
Terminated
·Philips North America, LLC·Product code MHX·March 5, 2020
TRx4841A 1.4 GHz IntelliVue Tele TRX, Model Number 862439; Includes System Codes 453564007261, 453564007271, 453564007281, 989803196951
FDA Enforcement
Class II
·Terminated·Philips North America, LLC·February 3, 2021
TRx4851A 2.4 GHz IntelliVue Tele TRX, Model Number 862231; Includes Service Numbers 453564052401, 453564052411, 453564052441, 453564052451, 453564166851, 453564166861
FDA Enforcement
Class II
·Terminated·Philips North America, LLC·February 3, 2021
Radiohead Access Point 1.4 GHz Radiohead Access Point Firmware versions: C.00.04 & C.00.05 Part Number: 989803171211 Product Usage: IntelliVue Smart-hopping 1.4 GHz Access Point provides wireless connectivity between IntelliVue devices (listed below) and the Philips IntelliVue Information Center. MX40 Indicated for use by health care professionals whenever there is a need for monitoring the physiological parameters of patients. Intended for monitoring and recording of, and to generate alarms for, multiple physiological parameters of adults and pediatrics in hospital environments and during transport inside hospitals. The MX4O is to be used primarily as a traditional telemetry medical device. It connects to the IntelliVue Information Center by way of a wireless network.
FDA Recall
Terminated
·Philips Healthcare Inc.·Product code MHX·July 8, 2013
Radiohead Access Point 1.4 GHz Radiohead Access Point Firmware versions: C.00.04 & C.00.05 Part Number: 989803171211 Product Usage: IntelliVue Smart-hopping 1.4 GHz Access Point provides wireless connectivity between IntelliVue devices (listed below) and the Philips IntelliVue Information Center. MX40 Indicated for use by health care professionals whenever there is a need for monitoring the physiological parameters of patients. Intended for monitoring and recording of, and to generate alarms for, multiple physiological parameters of adults and pediatrics in hospital environments and during transport inside hospitals. The MX4O is to be used primarily as a traditional telemetry medical device. It connects to the IntelliVue Information Center by way of a wireless network.
FDA Enforcement
Class II
·Terminated·Philips Healthcare Inc.·July 31, 2013
IntelliVue 1.4 GHz Remote Antenna Used with Philips MX4O Monitors-The affected product is a 74 foot (22.6m) combined coax and unshielded twisted pair data cable bundle and is a component of the Philips Remote Antenna (PN 867151). The Remote Antenna is used with IntelliVue MX40 Patient Worn Monitors in the USA, to extend the coverage area of a Core Access Point for the wireless Smart-hopping system.
FDA Recall
Terminated
·Philips North America, LLC·Product code MHX·August 23, 2019
MEDPOR Surgical Implant * POREX Surgical Products Group * Sterile/EO * Implant, Non-Pyrogenic, For Single Use Only, CAT #6317 DIM 20mm Diameter * Lot xxxxxx * QTY: 1 * Porex Surgical Inc., 15 Dart Road, Newnan, GA 30265 USA
FDA Recall
Terminated
·Porex Surgical, Inc.·Product code HPZ·March 7, 2005
Bio-Eye Hydroxyapatite (HA) Orbital Implant and Conformer, Model Number: 100020S
FDA Recall
Terminated
·Integrated Orbital Implants Inc·Product code HPZ·February 27, 2006
MEDPOR PLUS SST EZ 22mm Sphere Implant, Howmedica Osteonics Corp, 15 Dart Road, Newnan, GA 30265. MEDPOR PLUS Orbital Implants are intended to restore the volume of an enucleated or eviscerated eye globe.
FDA Recall
Terminated
·Howmedica Osteonics Corp dba Stryker Craniomaxillofacial·Product code HPZ·March 20, 2012
The 91220 mCare 300 Vital Signs monitor has a 10.4 inch resistive touchscreen display. The Spacelabs Medical, mCare 300, Model 91220, Vital Signs Monitor is a compact monitoring system with a resistive touchscreen display. It is indicated for use in adult, pediatric and neonate patient populations wherever there is a need for the monitoring of ECG, respiration, invasive or noninvasive blood pressures, body temperature, functional arterial oxygen saturation, or expired or minimum inspire CO2. The product is a prescription device intended to be used by healthcare professionals in all areas of a healthcare facility.
FDA Recall
Terminated
·Spacelabs Healthcare, Incorporated·Product code MHZ·April 14, 2010
Sterile Bio-Eye Hydroxyapatite Orbital Implant and Conformer
FDA Recall
Terminated
·Integrated Orbital Implants Inc·Product code HPZ·June 7, 2010
Product Brand Name: Coated Bio-Eye Orbital Implant w/Conformer. Product Generic Name: Implant, Eye Sphere Wrap, Implant, Orbital. Model Number: I0016C, I0018C, I0020C, I0022C, I0024C. Description of the product: The Coated Bio-Eye consists of a coralline hydroxyapatite sphere encased in a resorbable shell that aids in implant insertion and provides a means of securing muscles to the implant. The Coated Bio-Eye Orbital Implant is indicated in orbital implantation following enucleation, or as a secondary orbital implant following extrusion, migration or rotation of primary orbital implants. It is indicated in any situation where materials such as silicone, acrylic, polyethylene or glass orbital implants would be used.
FDA Recall
Terminated
·Integrated Orbital Implants Inc·Product code hpz·May 20, 2011
IntelliVue 1.4 GHz Remote Antenna Used with Philips MX4O Monitors-The affected product is a 74 foot (22.6m) combined coax and unshielded twisted pair data cable bundle and is a component of the Philips Remote Antenna (PN 867151). The Remote Antenna is used with IntelliVue MX40 Patient Worn Monitors in the USA, to extend the coverage area of a Core Access Point for the wireless Smart-hopping system.
FDA Enforcement
Class II
·Terminated·Philips North America, LLC·September 25, 2019
The Plum 360 is a large volume infuser capable of delivering fluids for a variety of therapies such as parenteral, enteral, or epidural infusions. The Plum 360 infuser can deliver fluids over a broad range of infusion rates and is capable of Concurrent delivery from one or more rigid or flexible fluid containers. The Plum 360 infuser features Concurrent, Secondary, and Piggyback infusions. A positive valving cassette allows two lines to be delivered at independent rates. The volume to be infused (VTBI) is delivered through one line to a patient. The two lines can be delivered in Concurrent mode (together) or Piggyback mode (one after another) without raising or lowering I.V. bags. The Plum 360 infuser also enables fluid pathway troubleshooting such as removing proximal air in line, without is disconnecting the patient line. The Plum 360 can act as a stand-alone infuser, or in conjunction with the Hospira MedNet software to provide medication safety software at the point of care, with customized drug libraries to support hospital defined protocols by clinical care area. In such a configuration, the Plum 360 infuser can communicate with systems on the network via Ethernet or state of the art wireless communication using an 802.11 a/b/g/n/, 2.4 GHz/5 GHz dual-band radio. The Plum 360 infuser and Hospira MedNet software interface with other hospital systems such as Electronic Health records, Electronic Medication Administration Records, Bar Code Point of Care, Real Time Location Services, and there systems. Each infuser includes a Connectivity Engine (CE) which provides both wired Ethernet and wireless 802.11 a/b/g/ networking capabilities. The Plum 360 infuser interfaces with Hospira MedNet application software to download drug library and infuser software updates and enable auto-programming of the infuser.The device may include means to detect a fault condition, such as air in, or blockage of, the infusion line and to activate an alarm.
FDA Recall
Terminated
·Hospira Inc.·Product code FRN·March 25, 2016
The Plum 360 is a large volume infuser capable of delivering fluids for a variety of therapies such as parenteral, enteral, or epidural infusions. The Plum 360 infuser can deliver fluids over a broad range of infusion rates and is capable of Concurrent delivery from one or more rigid or flexible fluid containers. The Plum 360 infuser features Concurrent, Secondary, and Piggyback infusions. A positive valving cassette allows two lines to be delivered at independent rates. The volume to be infused (VTBI) is delivered through one line to a patient. The two lines can be delivered in Concurrent mode (together) or Piggyback mode (one after another) without raising or lowering I.V. bags. The Plum 360 infuser also enables fluid pathway troubleshooting such as removing proximal air in line, without is disconnecting the patient line. The Plum 360 can act as a stand-alone infuser, or in conjunction with the Hospira MedNet software to provide medication safety software at the point of care, with customized drug libraries to support hospital defined protocols by clinical care area. In such a configuration, the Plum 360 infuser can communicate with systems on the network via Ethernet or state of the art wireless communication using an 802.11 a/b/g/n/, 2.4 GHz/5 GHz dual-band radio. The Plum 360 infuser and Hospira MedNet software interface with other hospital systems such as Electronic Health records, Electronic Medication Administration Records, Bar Code Point of Care, Real Time Location Services, and there systems. Each infuser includes a Connectivity Engine (CE) which provides both wired Ethernet and wireless 802.11 a/b/g/ networking capabilities. The Plum 360 infuser interfaces with Hospira MedNet application software to download drug library and infuser software updates and enable auto-programming of the infuser.The device may include means to detect a fault condition, such as air in, or blockage of, the infusion line and to activate an alarm.
FDA Enforcement
Class II
·Terminated·Hospira Inc.·June 15, 2016