14 results · 6ms · Sources: EU EUDAMED, US FDA

Get notified when this changes

We'll email you when new records match this search — new devices, new clearances, certificate changes, or withdrawals.

LMA (Laryngeal Mask Airway) Supreme (New Cuff) Size 5, Sterile, Single use, Product Usage: Achieve and maintain control of airway during routine anaesthesia in fasted patient using either spontaneous or positive pressure ventilation, cardiopulmonary resuscitation, the failed intubation situation and the cannot-intubate-cannot-ventilate situation.

FDA Enforcement
Class II ·Terminated·Teleflex Medical·February 18, 2015

Teleflex MEDICAL LMA(TM) MADgic(TM) LARYNGO-TRACHEAL MUCOSAL ATOMIZATION DEVICE, MAD700, QTY: 1 Intended for the application of topical anesthetics to the oropharynx and upper airway region

FDA Enforcement
Class II ·Terminated·Teleflex Medical Europe Ltd·May 9, 2018

LMA(TM) MADgic(TM) Laryngo-Tracheal Mucosal Atomization Devices: (a) MAD600 MADgic, (b) MAD700 MADgic, (c) MAD720 MADgic Intended for the application of topical anesthetics to the oropharynx and upper airway region

FDA Enforcement
Class II ·Terminated·Teleflex Medical·October 4, 2017

LMA Esophageal Intubation Detector (EID), Catalog Number EID100 The device is used to assist verification of placement of the endotracheal tube or esophageal/tracheal double lumen tube. This device is to be used as an adjunct to assess intubation. Its purpose is not to eliminate clinical judgment

FDA Enforcement
Class II ·Terminated·LMA North America Inc·July 25, 2012

LMA MADett, Endotracheal tube Mucosal Atomization Device, Rx only, Product Usage: These products are used for the delivery of topical anesthesia via an atomized spray to the oral, nasal, pharyngeal or laryngeal mucosa. Teleflex Medical is recalling these products as they may produce a straight stream instead of a fully atomized plume of medication. It is unlikely that serious adverse health consequences will occur in the event of a failure to deliver an atomized plume; however, this may result in inadequate topical anesthesia which may lead to some discomfort, further attempts to deliver topical anesthesia, or the use of alternative methods of anesthesia.

FDA Enforcement
Class II ·Terminated·Teleflex Medical·December 28, 2016

LMA MADdy, Rx only, Product Usage: These products are used for the delivery of topical anesthesia via an atomized spray to the oral, nasal, pharyngeal or laryngeal mucosa. Teleflex Medical is recalling these products as they may produce a straight stream instead of a fully atomized plume of medication. It is unlikely that serious adverse health consequences will occur in the event of a failure to deliver an atomized plume; however, this may result in inadequate topical anesthesia which may lead to some discomfort, further attempts to deliver topical anesthesia, or the use of alternative methods of anesthesia.

FDA Enforcement
Class II ·Terminated·Teleflex Medical·December 28, 2016

LMA MADomizer, Rx only, Product Usage: These products are used for the delivery of topical anesthesia via an atomized spray to the oral, nasal, pharyngeal or laryngeal mucosa. Teleflex Medical is recalling these products as they may produce a straight stream instead of a fully atomized plume of medication. It is unlikely that serious adverse health consequences will occur in the event of a failure to deliver an atomized plume; however, this may result in inadequate topical anesthesia which may lead to some discomfort, further attempts to deliver topical anesthesia, or the use of alternative methods of anesthesia.

FDA Enforcement
Class II ·Terminated·Teleflex Medical·December 28, 2016

LMA MADgic, Atomization Device with 3mL Syringe, Rx only, Product Usage: These products are used for the delivery of topical anesthesia via an atomized spray to the oral, nasal, pharyngeal or laryngeal mucosa. Teleflex Medical is recalling these products as they may produce a straight stream instead of a fully atomized plume of medication. It is unlikely that serious adverse health consequences will occur in the event of a failure to deliver an atomized plume; however, this may result in inadequate topical anesthesia which may lead to some discomfort, further attempts to deliver topical anesthesia, or the use of alternative methods of anesthesia.

FDA Enforcement
Class II ·Terminated·Teleflex Medical·December 28, 2016

TRUE Dilatation Balloon Valvuloplasty Catheter, REF Numbers: 02045-11, 02245-12, 02445-12, and 02645-13; Sizes: 20mm x 4.5cm, 22mm x 4.5cm, 24mm x 4.5cm, and 26mm x 4.5cm; Intended to be used for balloon aortic valvuloplasty.

FDA Enforcement
Class II ·Terminated·Loma Vista Medical·July 3, 2013

SOMATOM Force, System x-ray, tomography, computed

FDA Enforcement
Class II ·Terminated·Siemens Medical Solutions USA, Inc·December 14, 2016

Magellan Hypodermic Safety Needle, 25 G x 5/8" (0.508 mm x 1.6 cm). A single lumen needle intended to inject fluids into, or withdraw fluids from, parts of the body below the surface of the skin. Product Code: 8881850558

FDA Enforcement
Class II ·Terminated·Cardinal Health 200, LLC·March 24, 2021

Magellan 3 mL Syringe with Hypodermic Safety Needle, 25 G x 5/8" (0.508 mm x 1.6 cm). A single lumen needle intended to inject fluids into, or withdraw fluids from, parts of the body below the surface of the skin. Product Code: 8881833558

FDA Enforcement
Class II ·Terminated·Cardinal Health 200, LLC·March 24, 2021

Integra Ojemann Cortical Stimulator; Product / Catalogue No: OCS2. Intended for intraoperative cortical stimulation mapping procedures.

FDA Enforcement
Class II ·Terminated·Integra Burlington MA, Inc.·April 10, 2013

LIFESTREAM Balloon Expandable Vascular Covered Stent . BARD PERIPHERAL VASCULAR. 6mm X 26mm X 80 Recommended Introducer 6F (2.00mm) NP 8atm (811 kPa) Recommended Guide wire .035" (0.89mm) RBP 12 atm (1216 kPa) RX Only Lot numbers begins with CMA or CMB. Product Code Stent Diameter Stent length Catheter Length LSM0800626 6mm 26 mm 80 cm LSM1350626 6 mm 26 mm 135 cm LSM0800637 6 mm 37 mm 80 cm LSM1350637 6 mm 37 mm 135 cm LSM0800726 7 mm 26 mm 80 cm LSM1350726 7 mm 26 mm 135 cm Product Usage: The LIFESTREAM Balloon Expandable Vascular Covered Stent is indicated for the treatment of atherosclerotic lesions in common and external iliac arteries with reference vessel diameters between 4.5 mm and 12.0 mm, and lesions lengths up to 100mm.

FDA Enforcement
Class II ·Terminated·Bard Peripheral Vascular Inc·December 25, 2019