27 results · 7ms · Sources: EU EUDAMED, US FDA

Get notified when this changes

We'll email you when new records match this search — new devices, new clearances, certificate changes, or withdrawals.

SharePlan 1.1, aka t-RayAutoplan version 1.2.1 (build number 1.3.1.10). Manufacturing name RayAutoplan, aka t-RayAutoplan, commercial name (TomoTherapy) SharePlan Intended use: t-RayAutoplan is a software that, based on the planned dose distribution from a TomoPlan treatment planning system, generates a family of individually optimized IMRT plans and presents their characteristics to the user in a GUI. Among the generated plans, the user selects and clinically approves a treatment plan and exports it electronically to DICOM, for subsequent treatment of the patient. The intended users of t-RayAutoplan shall be clinically qualified staff, such as medical physicists, medical doctors or dosimetrists.

FDA Enforcement
Class II ·Terminated·RAYSEARCH LABORATORIES AB·October 3, 2012

EEA Circular Stapler with Tri-Staple Technology, Part No. TRIEEA28MT TRIEEA28XT TRIEEA31MT TRIEEA31XT Product Usage: The EEA Circular Stapler with Tri-Staple Technology places a circular, triple staggered row of titanium staples and resects the excess tissue, creating a circular anastomosis.

FDA Enforcement
Class II ·Terminated·COVIDIEN LLC·October 10, 2018

Contra-Angle Torque Driver Kit Product Usage: Molded plastic tray used in holding various dental instruments for autoclave processing.

FDA Enforcement
Class II ·Terminated·Biomet 3i, LLC·March 19, 2014

Contra-Angle Torque Driver Kit For Certain and External Connection Product Usage: Molded plastic tray used in holding various dental instruments for autoclave processing.

FDA Enforcement
Class II ·Terminated·Biomet 3i, LLC·March 19, 2014

Cytocell LPH019-A E2A (TCF3) Breakapart Probe- In Vitro Diagnostic Analyte specific reagents (ASR's)

FDA Enforcement
Class II ·Terminated·Cytocell Ltd.·August 25, 2021

Harmony Referral System (aka Harmony RS)/ Medical Device Data System - Product Usage: intended to be used by trained healthcare professionals and clinicians to access archived multimedia data, forms and patient information.

FDA Enforcement
Class II ·Terminated·Topcon Medical Systems, Inc.·February 10, 2021

Proton therapy system -Proteus 235 aka Proteus Plus. A medical device designed to produce and deliver a proton beam for the treatment of patients with localized tumors and other conditions susceptible to treatment by radiation.

FDA Enforcement
Class II ·Terminated·Ion Beam Applications S.A.·May 24, 2017

NOVAPLUS(R) Pregnancy Cassette Device with Droppers, Urine hCG Pregnancy Cassette, Cat. No. VPT1-CASS Product Usage: pregnancy test

FDA Enforcement
Class II ·Terminated·Ekla Corporation·July 18, 2018

EkoSonic Endovascular Devices EKOS Intelligent Drug Delivery Catheter

FDA Enforcement
Class II ·Terminated·EKOS Corporation·September 28, 2016

EkoSonic MACH4 Endovascular Device (Catalog #500-55106, 500-55112; 500-55118; 500-55124; 500-55130; 500-55140; 500-55150; 500-54106; 500-56130; 500-56140; 500-56150) is a catheter, continuous infusion. it consists of the Intelligent Drug Delivery Catheter (IDDC) and the MicroSonic Device (MSD). It is intended for the controlled and selective infusion of physician-specific fluids, including thrombolytics, into the peripheral vasculature. All therapeutic agents utilized with the EkoSonic Endovascular System should be fully prepared and used according to the instruction for use of the specific therapeutic agent. The Kit MACH4 is labeled in parts: "***EkoSonic MACH4 Endovascular Device***MicroSonic Device and Intelligent Drug Delivery Catheter***". The Pouch MSD is labeled in parts: "***EKOS***MicroSonic Device***Sterile***". EkoSonic Endovascular System is a catheter, continuous infusion. It is intended for the controlled and selective infusion of physician-specific fluids, including thrombolytics, into the peripheral vasculature. The system is also intended for the infusion of solutions into pulmonary arteries.

FDA Enforcement
Class II ·Terminated·EKOS Corporation·July 25, 2012

The EKOS EkoSonic Control Unit is intended exclusively for use with the EkoSonic Endovascular Device and the EkoSonic MACH4 Endovascular Device. The EkoSonic Endovascular System consists of three main components: -a single use EkoSonic Endovascular Device which is comprised of an Intelligent Drug Delivery Catheter (IDDC) and -removable MicroSonic Device (MSD), and -a reusable EKOS EkoSonic Control System. During use, fluids are delivered through the side-holes of the IDDC. The MSD is placed through the central lumen of the IDDC to deliver ultrasound energy along the length of fluid delivery, dispersing the fluid into the intravascular treatment site. The reusable EKOS EkoSonic Control Unit provides power to the system and the user interface for operator control. A reusable, nonsterile Connector Interface Cable connects the EKOS EkoSonic Control Unit to the EkoSonic Endovascular Device.

FDA Enforcement
Class II ·Terminated·EKOS Corporation·July 29, 2015

The EKOS cart has the catalog number 700-60101. The EKOS cart is a custom infusion stand/cart used to hold and transport the EkoSonic Control Unit. The cart is designed with three poles to hold infusion pumps and fluid bags, a tray on which the EkoSonic Control unit sits and a base designed to hold an Uninterruptable Power Supply (UPS). The cart mounts on 4 wheels, two locking and two non-locking.

FDA Enforcement
Class II ·Terminated·EKOS Corporation·October 5, 2016

The EkoSonic Endovascular System employs high frequency (2-2.5 MHz), low power (0.585 watt average power per transducer) ultrasound to facilitate the delivery of physician-specified fluids in the peripheral vasculature and to deliver solutions into the pulmonary arteries. The EkoSonic Endovascular System is intended for the controlled and selective infusion of physician-specified fluids, including thrombolytics, into the peripheral vasculature and the infusion of solutions into the pulmonary arteries. The reusable EKOS EkoSonic Control Unit provides power to the system and the user interface for operator control. A reusable, non sterile Connector Interface Cable connects the EKOS EkoSonic Control Unit to the EkoSonic Endovascular Device.

FDA Enforcement
Class II ·Terminated·EKOS Corporation·November 13, 2013

EkoSonic Endovascular System, Catalog Number 500-56112. It consists of three main components, a single use EkoSonic Endovascular Device which is comprised of an Intelligent Drug Delivery Catheter (IDDC) and removable MicroSonic Device (MSD), and a reusable EKOS EkoSonic Control System. During use, fluids are delivered through the side-holes of the IDDC. The MSD is placed through the central lumen of the IDDC to deliver ultrasound energy along the length of fluid delivery, dispersing the fluid into the intravascular treatment site. The reusable EKOS EkoSonic Control Unit provides power to the system and the user interface for operator control. A reusable, non-sterile Connector Interface Cable connects the EKOS EkoSonic Control Unit to the EkoSonic Endovascular Device.

FDA Enforcement
Class II ·Terminated·EKOS Corporation·March 2, 2016

Replacement LED PCB Kit, part number 001840, of the Natus neoBLUE (aka neoBLUE 2) Phototherapy system. Neonatal phototherapy.

FDA Enforcement
Class II ·Terminated·Natus Medical Incorporated·December 31, 2014

Medtronic Implantable Insulin Pump System, REF: MMT-2007D, Sterile EO, CE 0459 UDI: 00763000043001

FDA Enforcement
Class II ·Terminated·Medtronic Inc.·June 10, 2020

Schiller AG ISA CO2 Sensor (AKA: PhaseIn Unit), Merge Part Number HW-HEMO-00001. The PhaseIn Unit is an optional accessory (sold separately) to the Merge Hemo Patient Data Module (PDM). The PDM is a major component of the Merge Hemo system.

FDA Enforcement
Class II ·Terminated·Merge Healthcare, Inc.·May 10, 2017

The product affected by this notice is sold under the trade name TomoTherapy SharePlan 1.1. To determine if the version you are using is affected, bring up the About box in the SharePlan application and check if the build number reported there is 1.3.1.10. Intended use: t-RayAutoplan is a software that, based on the planned dose distribution from a TomoPlan treatment planning system, generates a family of individually optimized IMRT plans and presents their characteristics to the user in a GUI. Among the generated plans, the user selects and clinically approves a treatment plan and exports it electronically to DICOM, for subsequent treatment of the patient. The intended users of t-RayAutoplan shall be clinically qualified staff, such as medical physicists, medical doctors or dosimetrists

FDA Enforcement
Class II ·Terminated·RAYSEARCH LABORATORIES AB·September 26, 2012

Medtronic MiniMed Silhouette and/or MiniMed Sure-T Infusion Sets; Paradigm Silhouette infusion sets: MMT-368, MMT-368600, MMT-371, MMT-373, MMT-377, MMT-377600, MMT378, MMT-378600, MMT-38 1, MMT-381 600, MMT-382, MMT-382600, MMT-383, MMT-383600, MMT384, & MMT384600. Sure-T infusion sets MMT-862, MMT-863, MMT-864, MMT-865, MMT-866, MMT-873, MMT-874, MMTMMT-875, MMT-876, MMT-884, & MMT-886. MiniMed Duo sensor/infusion sets: MMT-5001A23, MMT-5001A43, MMT-5001B23, MMT-5001B43, MMT-5011A23, MMT-5011A43, MMT-5011B23, & MMT-5011B43. Silhouette and Sure-T disposable infusion sets are used with Medtronic insulin infusion pumps using Paradigm P-cap connectors. The infusion set connects the insulin reservoir in the pump to the patients body.

FDA Enforcement
Class II ·Terminated·Medtronic MiniMed Inc.·December 17, 2014

EEA" Hemorrhoid and Prolapse Stapler Set with DST Series" Technology 3.5MM, Product Number HEM3335, GTIN Number 1 - 10884521047518, GTIN Number 2 - 20884521047515 Product Usage: The EEA Hemorrhoid and prolapse stapler set with DST Series Technology (instrument) is designed for use as a stapler instrument for control of rectal prolapse and hemorrhoid disease. The instrument places a circular, double-staggered row of titanium DST staples and removes a circular tissue specimen. The instrument is offered in a 33mm diameter size with either 3.5mm or 4.8mm staples. The accompanying accessories comprised of an access port, anoscope, and dilator. The access port aids the insertion and removal of the anoscope and the stapler device by dilating the anal sphincter throughout the procedure. The anoscope is designed to facilitate pursestring suture application above the dentate line. It is designed with a guide and markings to assist in creating a circumferential pursestring suture at a consistent placement within the rectum. The dilator is designed to aid the initial insertion of the anoscope and port by retracting the rectal tissue. Both the anoscope and port are transparent to facilitate visualization of the anal canal. The EEA Hemorrhoid and prolapse stapler set with DST Series Technology has application throughout the anal canal to perform surgical treatment of hemorrhoidal disease. The EEA Hemorrhoid and prolapse stapler also has application in the distal alimentary tract for the creation of end-to-end and end-to-side anastomoses.

FDA Enforcement
Class II ·Terminated·Covidien LLC·May 2, 2018