COOK MEDICAL Spectrum Central Venous Catheter Set: Reference Part Number C-UDLM-401J-ABRM-HC, Order Number G43983; Reference Part Number C-UDLM-401J-ABRM-HC-CAH, Order Number G24754; Reference Part Number C-UDLM-401J-LSC-ABRM-HC, Order Number G43986; Reference Part Number C-UDLM-401J-PED-ABRM-HC, Order Number G43984; Reference Part Number C-UDLM-401J-PED-ABRM-HC-CAH, Order Number G24752; Reference Part Number C-UDLM-401J-RSC-ABRM-HC, Order Number G43985; Reference Part Number C-UDLM-501J-ABRM-HC, Order Number G43995; Reference Part Number C-UDLM-501J-PED-ABRM-HC, Order Number G43996; Reference Part Number C-UDLM-501J-RSC-ABRM-HC, Order Number G43997; Reference Part Number C-UDLM-801J-ABRM-HC, Order Number G50817; Reference Part Number C-UQLM-1001J-ABRM-HC-RD, Order Number G51537; Reference Part Number C-UQLM-1001J-RSC-ABRM-HC-RD, Order Number G51539; Reference Part Number C-UTLM-501J-ABRM-HC, Order Number G44005; Reference Part Number C-UTLM-501J-ABRM-HC-CAH, Order Number G24803; Reference Part Number C-UTLM-501J-LSC-ABRM-HC, Order Number G44008; Reference Part Number C-UTLM-501J-PED-ABRM-HC, Order Number G44006; Reference Part Number C-UTLM-501J-RSC-ABRM-HC, Order Number G44007; Reference Part Number C-UTLM-501J-RSC-ABRM-HC-CAH, Order Number G24765; Reference Part Number C-UTLM-701J-ABRM-HC-RD, Order Number G47825; Reference Part Number C-UTLM-701J-ABRM-HC-RD-CAH, Order Number G24809; Reference Part Number C-UTLM-701J-ABRM-HC-RD-P, Order Number G53599; Reference Part Number C-UTLM-701J-LSC-ABRM-HC-RD, Order Number G47827; Reference Part Number C-UTLM-701J-RSC-ABRM-HC-RD, Order Number G47829; Reference Part Number C-UTLM-701J-RSC-ABRM-HC-RD-CAH, Order Number G24810.

FDA Recall
Open, Classified ·Cook Incorporated·Product code FOZ·March 5, 2026

ETHIBOND EXCEL GRN 36IN(90CM) USP2-0(M3) D/A MH

FDA Recall
Open, Classified ·Ethicon Endo Surgery, LLC·Product code NEW·March 7, 2025

Medline medical procedure kits, labeled as follows: a) PARACERVICAL PUD TRAY, REF DYNDH1832; b) AHS PARACERVICAL/PUDENDAL KIT, REF DYNJRA2210; c) PARACERVICAL/PUDENDAL BLK KIT, REF DYNJRA9046; d) PARACERVICAL/PUDENDAL BLK KIT, REF DYNJRA9046H; Medical procedure convenience tray

FDA Recall
Open, Classified ·MEDLINE INDUSTRIES, LP Northfield·Product code OJH·March 1, 2024

Trinias, Digital Angiography System containing a MH-200, Ceiling Suspended C-arm Support - Product Usage: intended to be used for cardiac angiography, neurovascular angiography, abdominal angiography, peripheral angiography, rotational angiography, multi-purpose angiography and whole body radiographic/fluoroscopic procedures.

FDA Recall
Open, Classified ·Shimadzu Medical Systems·Product code OWB·November 18, 2020

The GSP 2021-0010 (Genetic Screening Processor) instrument is a fully automated, high through put batch analyzer for time- resolved and prompt fluorescence analysis of samples in microtitration plates. It is intended for in vitro quantitative / qualitative determination of analytes in body fluids. The chemistries running on the GSP instrument are used to test blood specimens dried on filter paper as an aid in screening newborns for congenital disorders.

FDA Recall
Terminated ·PerkinElmer LAS, Inc·Product code JLW·October 24, 2011

Infant Heel Warmer with Attachment Tab, Nonsterile, Active Product SKU MH00002T The infant heel warmer is activated at the point of care by squeezing the pouch. This mixes the substrates inside the pouch causing an exothermic chemical reaction, warming the pouch, which is then applied to the heel of an infant to aid in blood draws

FDA Recall
Terminated ·Cardinal Health·Product code MPO·June 9, 2021

Infant Heel Warmer without Attachment Tab, Nonsterile, Active Product SKU MH00002N The infant heel warmer is activated at the point of care by squeezing the pouch. This mixes the substrates inside the pouch causing an exothermic chemical reaction, warming the pouch, which is then applied to the heel of an infant to aid in blood draws

FDA Recall
Terminated ·Cardinal Health·Product code MPO·June 9, 2021

Mar Cor Purification CWP Reverse Osmosis System. Models 101, 102, 104, and 106.

FDA Recall
Terminated ·Mar Cor Purification·Product code FIP·June 27, 2012

Mar Cor Purification Millenium HX Portable Reverse Osmosis System. Model 3025975. Product Usage: Water Purification System is intended to be used as a dialysis accessory to produce water through reverse osmosis for use with hemodialysis equipment..

FDA Recall
Terminated ·Mar Cor Purification·Product code FIP·June 26, 2013

Mar Cor Purification, Central Water Platform (CWP), 102, 104 and 106. Product Usage: The CWP is a Central reverse osmosis system with the intended use of producing water for dialysis of multiple patients.

FDA Recall
Terminated ·Mar Cor Purification·Product code FIP·April 24, 2014

Tourni-Cot - Universal, UDI 00855364004085, Model Number TCU, Non-pneumatic Tourniquet - Product Usage: The device is intended to be used in surgery on fingers or toes to provide a blood-less field.

FDA Recall
Terminated ·Mar-Med Co·Product code GAX·December 28, 2020

Arkon Anesthesia Delivery System, Model 99999. Product Usage: Continuous Ventilator The Arkon Anesthesia Delivery System is designed to provide emergency oxygen, vaporized agent delivery and manual ventilation in the event of a power failure scenario. Clinicians are able to use Emergency O2 and manually ventilate the patient, providing gas and agent. However, the anesthesiologist will not have access to mechanical ventilation or ventilator monitoring.

FDA Recall
Terminated ·Del Mar Reynolds Medical, Ltd.·Product code CBK·February 8, 2017

Spacelabs Pediatric Flow Sensor Kit, PN: 376-0561-00. This kit is for Spacelabs Healthcare Blease 700/900 Series Ventilators. Designed specifically for the mechanical ventilation of adult and pediatric patients under general anesthesia.

FDA Recall
Terminated ·Del Mar Reynolds Medical, Ltd.·Product code CBK·March 5, 2015

Ultrasound Gel labeled under the following brand names: MediChoice Ultrasound Gel, Athena Liquasonic Ultrasound Gel, Eco-Med EcoGel Ultrasound Gel, MAC Medical Supply Ultrasound Gel, Eco-Med EcoGel 200 Blue High Velocity Ultrasound Gel, Eco-Med EcoGel 200 Multi-Purpose Ultrasound Gel, and Eco-Med EcoGel 200 Multi-Purpose CLEAR Ultrasound Gel

FDA Recall
Open, Classified ·Mac Medical Supply Co Inc·Product code ITX·August 4, 2021

Spacelabs Healthcare Arkon Anesthesia Delivery System is intended for use in the hospital environment and operating room. Absorber Adapter Assembly Service Kit, part number: 050-9045-00. Absorber Adapter Assembly, part number: 650-1648-01. Arkon Absorber Canister Carrier, part number: 380-0916-01.

FDA Recall
Terminated ·Del Mar Reynolds Medical, Ltd.·Product code BSZ·April 14, 2017

HME for Tracheostomized Patients, Item Code 353S13046 - Product Usage: indicated for single use on anesthetized patients and respiratory care patients who require a breathing circuit with ISO standard 15mm or 22 mm connectors.

FDA Recall
Open, Classified ·Product code CAH·April 29, 2021

Anesthesia circuit kit; CIRCUIT,ANES,EXTENDFLEX,120,LF DYNJAA10230

FDA Recall
Open, Classified ·Product code CAH·October 10, 2025

Acuson Diagnostic Ultrasound System Transducer; Model Number(s): L582 Linear Array Transducer for use on the 128XP Ultrasound System; Catalog Numbers: 23656 (New), 45441 (Refurb)

FDA Recall
Terminated ·Siemens Medical Solutions USA, Inc.·Product code MAA·March 31, 2003

Visualase Body Accessory Kit PN 020-3000. The individual components within the Visualase Body Accessory Kit are packaged in Tyvek pouches. The packaged devices are then placed into a cardboard box which is labeled with the Body Accessory Kit label. Labeled sterile. The visualization stylet is constructed of titanium and used during Visualase laser ablation procedures by inserting it into intracorporeal catheter lumens for improved catheter stiffness and MRI visualization during procedures.

FDA Recall
Terminated ·Medtronic Navigation, Inc.·Product code GAH·September 1, 2016

SafeStar 90 Plus Filter. Bidirectionally breathing system filter.

FDA Recall
Open, Classified ·Draeger, Inc.·Product code CAH·June 16, 2025