24 results
·
12ms
·
Sources: EU EUDAMED, US FDA
Filters
Status: Terminated
×
Leksell Gamma Knife C
FDA Recall
Terminated
·Elekta, Inc.·Product code IWB·August 1, 2006
Leksell Gamma Knife Perfexion, Radionuclide radiation therapy system. Article Number 715000, Elekta, Inc. Norcross, GA 30092. Teletherapy device intended for stereotactic irradiation of head structures ranging from very small target sized os a few millimeters to several centimeters.
FDA Recall
Terminated
·Elekta, Inc.·Product code IWB·November 9, 2008
Digital Lightbox, BrainLAB system, image processing, radiological Product Usage: The Patient Data Manager is a system intended for the display of medical images. The software can transfer images to and from picture archiving and communication systems (PACS), file servers, or removable storage media. It includes functions for image manipulation, basic measurements and 3D visualization (reconstructions and volume rendering). Features for navigation planning include multi-modality image fusion as well as object and trajectory creation. It is not intended for primary image diagnosis or the review of mammographic images.
FDA Enforcement
Class II
·Terminated·Brainlab AG·November 11, 2015
Spectra Optia Apheresis System, REF: 61000, Caridian BCT, Lakewood, CO 80215. A blood component separator used for therapeutic plasma exchanges.
FDA Recall
Terminated
·Caridian BCT, Incorporated·Product code LKN·September 21, 2011
Leksell Gamma Knife C
FDA Recall
Terminated
·Elekta, Inc.·Product code IWB·September 1, 2006
Cosmetic color soft contact lenses. Multiple colors which include Blue, Green, Aqua, Brown, Grey. BesCon (brand)
FDA Recall
Terminated
·My Cosmetics Inc·Product code LPL·November 13, 2002
2.3mm Turbo-Power OTW, Manual, Model No 423-050 Product Usage The Turbo-Power System (Laser Atherectomy Catheter) is a laser atherectomy device designed for use with the CVX-300" Excimer Laser System. The Turbo-Power Laser Atherectomy Catheter is a sterile, single use, prescription only device used for peripheral atherectomy. Turbo-Power is used exclusively with SPNC s CVX 300" Excimer Laser System and is a Type CF device, Defibrillation proof. Turbo-Power is a laser atherectomy catheter designed for treatment of de novo or restenotic lesions in native infrainguinal arteries and for the treatment of femoropopliteal artery in-stent restenosis (ISR) in bare nitinol stents, with adjunctive Percutaneous Transluminal Angioplasty (PTA). Turbo-Power is used to directionally ablate infrainguinal concentric and eccentric lesions in vessels that are 3.5 mm or greater in diameter. The device is comprised of three parts: the working length of the catheter shaft (also the applied part), the motor drive unit (MDU), and the proximal laser shaft which connects the catheter fiber optics to the CVX-300" Excimer Laser System.
FDA Enforcement
Class II
·Terminated·Spectranetics Corp.·February 17, 2016
PREMIER Cryptococcal Antigen, Catalog Number 602096 Product Usage: The PREMIER Cryptococcal Antigen enzyme immunoassay (EIA) is a screening or a semi-quantitative test system for the detection of capsular polysaccharide antigens of Cryptococcus neoformans in serum and cerebrosoinal fluid (CSF).
FDA Recall
Terminated
·Meridian Bioscience Inc·Product code MDU·December 17, 2018
ChemoPlus" Chemo Prep & Admin Kit, CT4025
FDA Recall
Terminated
·Cardinal Health 200, LLC·Product code LYU·January 7, 2021
BlockAid Cut Resistant Surgical Glove Liners, combine stainless steel and synthetic fibers woven together to form a cut resistant glove material. Blockaid Cut Resistant Surgical Glove Liners are to be worn between two layers of surgical gloves. Item Number: 650126, 650127, 650128, 650129, 650130, 650131
FDA Recall
Terminated
·Zimmer Biomet, Inc.·Product code LYU·September 11, 2017
Covidien ChemoPlus Chemo Spill Kit, Nonsterile, SKU DP5108K
FDA Recall
Terminated
·Cardinal Health 200, LLC·Product code LYU·January 7, 2021
CHEMOPLUS DRUG SPILL KIT HOS, SKU CT4004
FDA Recall
Terminated
·Cardinal Health 200, LLC·Product code LYU·January 7, 2021
Kendall Spill Kit, 6 Per Case, NonsterileI, BB6016K
FDA Recall
Terminated
·Cardinal Health 200, LLC·Product code LYU·January 7, 2021
CHEMOBLOC Preparation and Administration Kit, Extra Large Blue Gown, Medium and Large Gloves, Nonsterile, SKU DP5106K
FDA Recall
Terminated
·Cardinal Health 200, LLC·Product code LYU·January 7, 2021
ChemoPlus Drug Spill Kit-INSTI, SKU DP5016K
FDA Recall
Terminated
·Cardinal Health 200, LLC·Product code LYU·January 7, 2021
2.3mm Turbo-Power OTW, Manual, Model No 423-050 Product Usage The Turbo-Power System (Laser Atherectomy Catheter) is a laser atherectomy device designed for use with the CVX-300" Excimer Laser System. The Turbo-Power Laser Atherectomy Catheter is a sterile, single use, prescription only device used for peripheral atherectomy. Turbo-Power is used exclusively with SPNC s CVX 300" Excimer Laser System and is a Type CF device, Defibrillation proof. Turbo-Power is a laser atherectomy catheter designed for treatment of de novo or restenotic lesions in native infrainguinal arteries and for the treatment of femoropopliteal artery in-stent restenosis (ISR) in bare nitinol stents, with adjunctive Percutaneous Transluminal Angioplasty (PTA). Turbo-Power is used to directionally ablate infrainguinal concentric and eccentric lesions in vessels that are 3.5 mm or greater in diameter. The device is comprised of three parts: the working length of the catheter shaft (also the applied part), the motor drive unit (MDU), and the proximal laser shaft which connects the catheter fiber optics to the CVX-300" Excimer Laser System.
FDA Recall
Terminated
·Spectranetics Corp.·Product code MCW·January 15, 2016
Cardiac Function Analysis Software Product Data No. MPDCT0301EAD CSCF-003A The software is applicable to the following CT systems: Aquilion ONE TSX-301A/2D X-ray CT system with a 320-row 0.5 mm detector is provided with a 7.5-MHU large-capacity X-ray tube unit, and permits scanning over large areas at the high-speed of 0.35 s per rotation. The system features are; 160-mm-wide area detector, station, gantry and patient couch operation controls, image reconstruction, high-speed volume scan, high-quality images, selectable image slice thickness, dual-monitor system, improved image diagnosis functions, high-speed volume data workflow, exposure reduction, ECG-gated scan and reconstruction, and SUREFluoro.
FDA Enforcement
Class II
·Terminated·Toshiba American Medical Systems Inc·December 3, 2014
Cardiac Function Analysis Software Product Data No. MPDCT0301EAD CSCF-003A The software is applicable to the following CT systems: Aquilion ONE TSX-301A/2D X-ray CT system with a 320-row 0.5 mm detector is provided with a 7.5-MHU large-capacity X-ray tube unit, and permits scanning over large areas at the high-speed of 0.35 s per rotation. The system features are; 160-mm-wide area detector, station, gantry and patient couch operation controls, image reconstruction, high-speed volume scan, high-quality images, selectable image slice thickness, dual-monitor system, improved image diagnosis functions, high-speed volume data workflow, exposure reduction, ECG-gated scan and reconstruction, and SUREFluoro.
FDA Recall
Terminated
·Toshiba American Medical Systems Inc·Product code JAK·November 5, 2014
Stryker Orthopaedics Triathlon femoral component. Howmedica Osteonics Corp., A subsidiary of Stryker Corporation Made in USA Sterile. For use in total reconstructive replacement of the knee joint
FDA Enforcement
Class II
·Terminated·Stryker Howmedica Osteonics Corp.·May 27, 2015
Cardiac Function Analysis Software Product Data No. MPDCT0301EAD CSCF-003A The software is applicable to the following CT systems: Aquilion ONE TSX-301C X-ray CT system with a 320-row 0.5 mm detector is provided with a 7.5-MHU large-capacity X-ray tube unit, and permits scanning over large areas at the high-speed of 0.35 s per rotation. The system features are; 160-mm-wide area detector, station, gantry and patient couch operation controls, image reconstruction, high-speed volume scan, high-quality images, selectable image slice thickness, dual-monitor system, improved image diagnosis functions, high-speed volume data workflow, exposure reduction, ECG-gated scan and reconstruction, and SUREFluoro. The CT cardiac function analysis software is used to analyze cardiac function using data obtained by performing cardiac MPR processing for ECG-gated scan data according to the cardiac axis. Aquilion ONE is a dynamic volume CT system that supports whole-body scanning. This 320-detector row system generates 640 slices per rotation using the coneXact reconstruction algorithm. In addition, the high-speed rotation mechanism and the fast reconstruction unit of the system allow the rapid image acquisition to further improve throughput in CT examinations.
FDA Enforcement
Class II
·Terminated·Toshiba American Medical Systems Inc·December 3, 2014