The System is designed as a modular system with components that include an Overhead Tube Suspension with tube/collimator, wallstand, Table, X-ray generator, and cleared wireless digital detectors. The list of detectors verified and validated for use with the Discovery XR656 HD system, including their specifications, are provided in the user documentation. The System generates diagnostic The components may be combined in different configurations to meet specific customer needs. In addition, upgrade configurations are available for predicate devices. The optional image pasting function enables the operator to stitch sequentially acquired radiographs into a single image. This 510(k) is to incorporate the VolumeRad advanced application that was currently available on the Discovery XR656 product onto the Discovery XR656 HD, as well as introduce a new Metal Artifact Reduction Algorithm, and an optional standalone console to take any HelixTM acquired images via DICOM (such as from a Discovery XR656 HD, Optima XR646 HD, or Optima XR240amx) and process the images independently of the system it was acquired on.

FDA Recall
Open, Classified ·GE Hangwei Medical Systems, Co. LTD West Area Bldg. 3, No.1 Yongchang North Road 1 Yongchangbeilu; Beijing Economic and Technological Development Area Beijing China·Product code KPR·November 7, 2023

The System is designed as a modular system with components that include an Overhead Tube Suspension with tube/collimator, wallstand, Table, X-ray generator, and cleared wireless digital detectors. The list of detectors verified and validated for use with the Discovery XR656 HD system, including their specifications, are provided in the user documentation. The System generates diagnostic The components may be combined in different configurations to meet specific customer needs. In addition, upgrade configurations are available for predicate devices. The optional image pasting function enables the operator to stitch sequentially acquired radiographs into a single image. This 510(k) is to incorporate the VolumeRad advanced application that was currently available on the Discovery XR656 product onto the Discovery XR656 HD, as well as introduce a new Metal Artifact Reduction Algorithm, and an optional standalone console to take any HelixTM acquired images via DICOM (such as from a Discovery XR656 HD, Optima XR646 HD, or Optima XR240amx) and process the images independently of the system it was acquired on.

FDA Recall
Open, Classified ·GE Hangwei Medical Systems, Co. LTD West Area Bldg. 3, No.1 Yongchang North Road 1 Yongchangbeilu; Beijing Economic and Technological Development Area Beijing China·Product code KPR·November 7, 2023

IMMAGE Immunochemistry Systems IGM Immunoglobulin M Reagent REF 447610 IGM reagent, when used in conjunction with IMMAGE Immunochemistry Systems and Calibrator 1, is intended for the quantitative determination of immunoglobulin M (IGM) in human serum by rate nephelometry.

FDA Recall
Open, Classified ·Beckman Coulter Inc.·Product code DEW·July 31, 2024

TCube One Step Multi-Drug Oral Fluid Test Cube (AMPSO,COC20,METSO, OPl40,OXY20,THC2S) Product Usage: T-Cube One Step Multi-Drug Oral Fluid Test Cube is a rapid oral fluid screening test. The test is a lateral flow, one-step immunoassay for the qualitative detection of specific drugs and their metabolites in human oral fluid at the following cut off concentrations for use in employment and insurance testing. The assay provides a qualitative, preliminary test result. A more specific analytical method must be used in order to obtain a confirmed result. Gas Chromatography/Mass Spectrometry (GC/MS) or Liquid Chromatography/Tandem Mass Spectrometry (LC/MS-MS) are preferred confirmatory methods. Professional judgment should be applied to any drug test result, particularly when preliminary results are positive.

FDA Recall
Open, Classified ·Guangzhou Wondfo Biotech Co., Ltd.·Product code DIS·May 18, 2018

LIFESTYLES ULTRA SENSITIVE CONDOMS 12CT, SKU 900265

FDA Recall
Open, Classified ·Family Dollar Stores, Llc.·Product code HIS·June 23, 2022

TCube One Step Multi-Drug Oral Fluid Test Cube (AMPSO, BARGO, SUPS, BZ030, COC20,MDMAlOO, METSO, OPl40,OXY20,THC2S) Product Usage: T-Cube One Step Multi-Drug Oral Fluid Test Cube is a rapid oral fluid screening test. The test is a lateral flow, one-step immunoassay for the qualitative detection of specific drugs and their metabolites in human oral fluid at the following cut off concentrations for use in employment and insurance testing. The assay provides a qualitative, preliminary test result. A more specific analytical method must be used in order to obtain a confirmed result. Gas Chromatography/Mass Spectrometry (GC/MS) or Liquid Chromatography/Tandem Mass Spectrometry (LC/MS-MS) are preferred confirmatory methods. Professional judgment should be applied to any drug test result, particularly when preliminary results are positive.

FDA Recall
Open, Classified ·Guangzhou Wondfo Biotech Co., Ltd.·Product code DIS·May 18, 2018

Condoms, labeled as: TROJAN MAGNUM CONDOMS 6/DSP BLACK, TROJAN LUBRICATED CONDOMS 6/DSP LITE BLUE, TROJAN SPERMICIDE CONDOMS 6/DSP DARK BLUE, TROJAN ULTRA THIN CONDOMS 6/DSP GREY, TROJAN RIBBED CONDOMS 6/DSP GOLD/BROWN, TROJAN NONLUBRICATED CONDOMS 6/DSP RED, TROJAN ULTRA HER PLEASURE CONDOMS 6/DSP, TROJAN CONDOMS MAGNUM 48 CT DISP, *BOX TROJAN CONDOMS MAGNUM 50CT .

FDA Recall
Open, Classified ·GOLD STAR DISTRIBUTION INC·Product code HIS·December 26, 2025

TCube One Step Multi-Drug Oral Fluid Test Cube (AMPSO, BARGO, BZ030,COC20,MDMA100,METSO, MTD30,OPl40,OXY20, THC2S) Product Usage: T-Cube One Step Multi-Drug Oral Fluid Test Cube is a rapid oral fluid screening test. The test is a lateral flow, one-step immunoassay for the qualitative detection of specific drugs and their metabolites in human oral fluid at the following cut off concentrations for use in employment and insurance testing. The assay provides a qualitative, preliminary test result. A more specific analytical method must be used in order to obtain a confirmed result. Gas Chromatography/Mass Spectrometry (GC/MS) or Liquid Chromatography/Tandem Mass Spectrometry (LC/MS-MS) are preferred confirmatory methods. Professional judgment should be applied to any drug test result, particularly when preliminary results are positive.

FDA Recall
Open, Classified ·Guangzhou Wondfo Biotech Co., Ltd.·Product code DIS·May 18, 2018

VITEK 2 Gram-negative AST Test Kits (Cards) containing Colistin formulation cs02n. VITEK 2 is an automated system consisting of instruments, software and reagent cards designed for the identification and antimicrobial susceptibility testing of bacteria and yeast. Export only

FDA Recall
Open, Classified ·bioMerieux, Inc.·Product code LON·June 26, 2025

Scan Monitor/ScanWatch, model number hwa09 Wearable, Bluetooth-connected wrist watch that records heart activity (ECG) and oxygen saturation (SpO2)

FDA Recall
Open, Classified ·Withings 37 Bis Rue Du General Leclerc Issy les Moulineaux CEDEX France·Product code DPS·December 19, 2022

REF: 126590, MEDLINE, STERILE ULTRASOUND GEL, 0.70 FL oz. (20 mL), QTY: 50, STERILER, CE 2292

FDA Recall
Open, Classified ·Turkuaz Saglik Hizmetleri Medikal Temizlik Kim. Ur. San. ve Tic. A.S. Akcaburgaz Mahallesi Muhsin Yazicioglu Caddesi No:45/5 Esenyurt Turkey·Product code MUI·June 9, 2023