27 results
·
22ms
·
Sources: EU EUDAMED, US FDA
Filters
Regulation: Us FDA
×
COMPURECORD PERI-OPERATIVE ANESTHESIOLOGY INFORMATION SYSTEM
FDA 510(k)
FDA Class 2
·Anesthesiology
N/A
FDA UDI
GEORGE TIEMANN & CO.·B582083413·HOOK, SURGICAL, GENERAL & PLASTIC SURGERY
Navagio
FDA UDI
Kalitec Direct LLC·B07330K0134130·Trial, TLIF, 27L OB STR 7Deg, 13mm
ALUMINA V40 HEAD
FDA 510(k)
FDA Class 2
·Orthopedic
MICROMARK II TISSUE MARKER,MODEL C1535
FDA 510(k)
FDA Class 2
·General, Plastic Surgery
TRUWAVE
FDA Adverse Event
Malfunction
·EDWARDS LIFESCIENCES DR·Product code DXO·April 22, 2026
PLATE, FIXATION, BONE
FDA Adverse Event
Malfunction
·SYNTHES USA·Product code HRS·November 16, 2015
4.0MM CANCELLOUS BONE SCREW PARTIALLY THREADED/45MM
FDA Adverse Event
Malfunction
·SYNTHES USA·Product code HWC·December 9, 2015
AWL 16.5/3.2 CANN
FDA Adverse Event
Malfunction
·SYNTHES GMBH·Product code FZX·April 29, 2013
3.5MM LOCKING SCREW SELF-TAPPING 40MM
FDA Adverse Event
Injury
·SYNTHES GMBH·Product code KTT·April 29, 2011
9610617-2008-00016
FDA Adverse Event
Other
·Product code FPK·July 12, 2008
TRUWAVE
FDA Adverse Event
Injury
·EDWARDS LIFESCIENCES DR·Product code DXO·March 27, 2025
TRUWAVE
FDA Adverse Event
Malfunction
·EDWARDS LIFESCIENCES DR·Product code DXO·April 10, 2025
TRUWAVE
FDA Adverse Event
Malfunction
·EDWARDS LIFESCIENCES DR·Product code DXO·September 5, 2025
SCREW, FIXATION, BONE
FDA Adverse Event
Injury
·SYNTHES (USA)·Product code HWC·September 1, 2016
SCREW, FIXATION, BONE
FDA Adverse Event
Injury
·SYNTHES USA·Product code HWC·December 4, 2015
4.0MM CANCELLOUS BONE SCREW FULLY THREADED/45MM
FDA Adverse Event
Injury
·SYNTHES GRENCHEN·Product code HWC·December 18, 2015
ASR ACETABULAR CUPS 68, DEPUY ASR XL MODULAR ACETABULAR CUP SYSTEM. The DePuy ASR XL Modular Acetabular Cup components are part of a modular system designed to replace the natural articular surface of the hip joint in total hip replacement. The acetabular cup is designed as a cobalt-chrome-molybdenum (CoCrMo) alloy one piece cup with a porous coating and is available in outer diameter sizes 64mm through 70mm in two-millimeter increments. The outer surface of the cup has a porous coating with the addition of a hydroxyapatite (HA) coating. There are no separate liner components to this system, as the liners are integral to the one-piece acetabular cups. Two cup configurations will be offered: a "spiked" cup with three fixation spikes on the outer surface of the cup for adjunct fixation, and an acetabular cup with no spikes. Both configurations are specific to the DePuy ASRTM Modular Cup System cleared in K040627 and K073413. This submission is a line extension of the acetabular cup components. These acetabular cups will be compatible with DePuy ASRTM femoral components. The uni femoral head is manufactured from cobalt-chrome-molybdenum (CoCrMo) alloy and is available in a range of diameters from 57mm to 63mm in two-millimeter increments. The uni femoral heads have an internal taper which mates with a taper sleeve adapter specific to DePuy 12/14 or 11/13 tapers. The femoral heads articulate with corresponding one-piece metal acetabular cups. The subject heads use taper sleeve adapters to mate the DePuy femoral heads to DePuy femoral stems and are manufactured from cobalt-chrome-molybdenum (CoCrMo) alloy. Prescription Use, Sterile The device is part of a modular system for use in total hip replacement in which the acetabular component articulates with a femoral component. The DePuy ASR XL Modular Acetabular Cup System is compatible with DePuy ASRT femoral components. The device is indicated for use in the following conditions, where there is evidence of sufficient sound bone to seat and support the components: 1. A severely painful and/or disabled joint from osteoarthritis, traumatic arthritis, rheumatoid arthritis, or congenital hip dysplasia. 2. Avascular necrosis of the femoral head. 3. Acute traumatic fracture of the femoral head and neck. 4. Failed previous hip surgery, including internal fixation, arthrodesis and hemiarthroplasty. 5. Certain cases of ankylosis. Porous-coated DePuy ASR MXL Modular Acetabular Cups are indicated for cementless application.
FDA Recall
Terminated
·Depuy Orthopaedics, Inc.·Product code KWA·August 23, 2010
ASR ACETABULAR CUPS 70, DEPUY ASR XL ACETABULAR CUP SYSTEM. The DePuy ASR XL Acetabular Cup components are part of a system designed to replace the natural articular surface of the hip joint in total hip replacement. The acetabular cup is designed as a cobalt-chrome-molybdenum (CoCrMo) alloy one piece cup with a porous coating and is available in outer diameter sizes 64mm through 70mm in two-millimeter increments. The outer surface of the cup has a porous coating with the addition of a hydroxyapatite (HA) coating. There are no separate liner components to this system, as the liners are integral to the one-piece acetabular cups. Two cup configurations will be offered: a "spiked" cup with three fixation spikes on the outer surface of the cup for adjunct fixation, and an acetabular cup with no spikes. Both configurations are specific to the DePuy ASRTM Modular Cup System cleared in K040627 and K073413. This submission is a line extension of the acetabular cup components. These acetabular cups will be compatible with DePuy ASRTM femoral components. The uni femoral head is manufactured from cobalt-chrome-molybdenum (CoCrMo) alloy and is available in a range of diameters from 57mm to 63mm in two-millimeter increments. The uni femoral heads have an internal taper which mates with a taper sleeve adapter specific to DePuy 12/14 or 11/13 tapers. The femoral heads articulate with corresponding one-piece metal acetabular cups. The subject heads use taper sleeve adapters to mate the DePuy femoral heads to DePuy femoral stems and are manufactured from cobalt-chrome-molybdenum (CoCrMo) alloy. Prescription Use, Sterile The device is part of a system for use in total hip replacement in which the acetabular component articulates with a femoral component. The DePuy ASR XL Acetabular Cup System is compatible with DePuy ASRT femoral components. The device is indicated for use in the following conditions, where there is evidence of sufficient sound bone to seat and support the components: 1. A severely painful and/or disabled joint from osteoarthritis, traumatic arthritis, rheumatoid arthritis, or congenital hip dysplasia. 2. Avascular necrosis of the femoral head. 3. Acute traumatic fracture of the femoral head and neck. 4. Failed previous hip surgery, including internal fixation, arthrodesis and hemiarthroplasty. 5. Certain cases of ankylosis. Porous-coated DePuy ASR MXL Acetabular Cups are indicated for cementless application.
FDA Recall
Terminated
·Depuy Orthopaedics, Inc.·Product code KWA·August 23, 2010
ASR 300 Size 66, DEPUY ASR XL ACETABULAR CUP SYSTEM. The DePuy ASR XL Acetabular Cup components are part of a system designed to replace the natural articular surface of the hip joint in total hip replacement. The acetabular cup is designed as a cobalt-chrome-molybdenum (CoCrMo) alloy one piece cup with a porous coating and is available in outer diameter sizes 64mm through 70mm in two-millimeter increments. The outer surface of the cup has a porous coating with the addition of a hydroxyapatite (HA) coating. There are no separate liner components to this system, as the liners are integral to the one-piece acetabular cups. Two cup configurations will be offered: a "spiked" cup with three fixation spikes on the outer surface of the cup for adjunct fixation, and an acetabular cup with no spikes. Both configurations are specific to the DePuy ASRTM Modular Cup System cleared in K040627 and K073413. This submission is a line extension of the acetabular cup components. These acetabular cups will be compatible with DePuy ASRTM femoral components. The uni femoral head is manufactured from cobalt-chrome-molybdenum (CoCrMo) alloy and is available in a range of diameters from 57mm to 63mm in two-millimeter increments. The uni femoral heads have an internal taper which mates with a taper sleeve adapter specific to DePuy 12/14 or 11/13 tapers. The femoral heads articulate with corresponding one-piece metal acetabular cups. The subject heads use taper sleeve adapters to mate the DePuy femoral heads to DePuy femoral stems and are manufactured from cobalt-chrome-molybdenum (CoCrMo) alloy. Prescription Use, Sterile The device is part of a system for use in total hip replacement in which the acetabular component articulates with a femoral component. The DePuy ASR XL Acetabular Cup System is compatible with DePuy ASRT femoral components. The device is indicated for use in the following conditions, where there is evidence of sufficient sound bone to seat and support the components: 1. A severely painful and/or disabled joint from osteoarthritis, traumatic arthritis, rheumatoid arthritis, or congenital hip dysplasia. 2. Avascular necrosis of the femoral head. 3. Acute traumatic fracture of the femoral head and neck. 4. Failed previous hip surgery, including internal fixation, arthrodesis and hemiarthroplasty. 5. Certain cases of ankylosis. Porous-coated DePuy ASR MXL Acetabular Cups are indicated for cementless application
FDA Recall
Terminated
·Depuy Orthopaedics, Inc.·Product code KWA·August 23, 2010