EnLite Neonatal TREC Kit;an in vitro diagnostic device intended for the semi-quantitative determination of TREC (T-cell receptor excision circle) DNA in blood specimens dried on filter paper. The test is for use on the VICTOR" EnLite instrument. The test is indicated for use as an aid in screening newborns for severe combined immunodeficiency disorder (SCID). Product Number: 3401-001U
FDA Recall
Terminated
·PerkinElmer Health Sciences, Inc.·Product code PJI·December 5, 2016
ABL 80 CO-OX SYSTEM, software versions 1.30 and 1.31 Additional Product Codes: CEM, CGA, CGZ, GHS, GKR, GLY, JFP, JGS, JIX, JJY, JPI The ABL 80 CO-OX SYSTEM is a portable, automated analyzer that measures pH, blood gases, electrolytes, glucose and oximetry in whole blood. The ABL 80 CO-OX SYSTEM is intended for use by trained technologists, nurses, physicians and therapists. It is intended for use in a laboratory environment, near patient or point-of-care setting.
FDA Recall
Terminated
·Sendx Medical Inc·Product code CHL·February 20, 2009
GE Nuclear Medicine 600/800 series systems, specifically: a) 850, b) 850 / Dismount, c) 850 3/8 inch NM Gantry, d) 860 / Dismount, e) 860 3/8 inch NM Gantry, f) 860 5/8 inch NM Gantry, g) 860 BJ, h) NM 830 3/8 inch BJ, i) NM/CT 850 3/8 inch BJ, j) NM/CT 850 3/8 inch ROW, k) NM/CT 850 3/8 inch ROW_, l) NM/CT 850 CT 850 3/8 inch, m) NM/CT 850 ES 3/8 inch, n) NM/CT 850 ES 3/8 inch ROW, o) NM/CT 860 3/8 inch, p) NM/CT 860 3/8 inch BJ, q) NM/CT 860 3/8 inch ROW, r) NM/CT 860 ADVANCE, s) NM/CT 860 advance 3/8 inch NM Gantry, t) NM/CT 860 BEYOND, u) NM/CT 860 beyond 3/8 inch NM Gantry, v) NM/CT 860 China for China, w) NM/CT 860 CT 860 3/8 inch, x) NM/CT 860 ES 3/8 inch, y) NM/CT 860 ES 3/8 inch ROW, z) NM/CT 850 3/8 inch, aa) NM/CT 850 ES 3/8 inch ROW, bb) NM/CT 860 3/8 inch CH, cc) XELERIS 4 DR WORKSTATION; Emission Computed Tomography System
FDA Recall
Open, Classified
·GE MEDICAL SYSTEMS ISRAEL, FUNCTIONAL IMAGING 4, Hayozma St Tirat Carmel Israel·Product code KPS·December 19, 2022
GE Nuclear Medicine 600/800 series systems, specifically: a) 830, b) 830 / Dismount, c) 830 /, d) 830 / 5842894-20, e) 830 / Dismount / 50HZ, f) 830 / Dismount / 60HZ, g) 830 3/8 inch Detector, h) 830 BJ, i) 830 BJ / 5144407, j) 830 BJ / Dismount, k) 830 ES DEM, l) 830 NM Cyber Defense Configuration Gantry 3/8 inch, m) 830 NM Gantry 3/8 inch, n) 830 NM Gantry 5/8 inch, o) 870 DR NM GANTRY FINAL - NEW ROTOR, p) B615 to D630 UPG, q) D630 NM GANTRY, r) D630 NM GANTRY 3/8 inch WITH NEW ROTOR - MEA, s) D630 NM Gantry 3/8 inch, t) D630 NM GANTRY FINAL ASSEMBLY_, u) D630 with new rotor, v) D630 with new rotor/ 5144407 / Dismount, w) D630 with new rotor/ Dismount, x) DISCOVERY D630 X 3/8 inch, y) DISCOVERY D630 X 3/8 inch, z) DISCOVERY D630 X 3/8 inch, aa) DISCOVERY D630 x 3/8 inch BHW, bb) DISCOVERY D630 X 3/8 inch BJG, cc) DISCOVERY D630 X 3/8 inch MEA, dd) DISCOVERY NM 830 3/8 inch, ee) DISCOVERY NM 830 3/8 inch, ff) NM 830 3/8 inch, gg) NM 830 3/8 inch BJ, hh) NM 830 ES, ii) NM DISCOVERY D630 3/8 inch, jj) NUC GOLDSEAL D630 X 3/8 inch. Emission Computed Tomography System
FDA Recall
Open, Classified
·GE MEDICAL SYSTEMS ISRAEL, FUNCTIONAL IMAGING 4, Hayozma St Tirat Carmel Israel·Product code KPS·December 19, 2022
Calcium Arsenazo, CALA-0250, For the Quantitative Determination of Total Calcium in Human Serum. The kit label shows CALCIUM ARSENAZO, CALA-0250, R: 12x20 mL. The vial's label shows CALCIUM ARSENAZO, CALA-5220, 20 mL, . CALCIUM ARSENAZO is intended use for the quantitative in vitro diagnostic determination of total calcium in human serum and plasma on ELITech Clinical Systems Selectra Pro Series Analyzers. Calcium measurements are used in the diagnosis and treatment of parathyroid disease, a variety of bone diseases, chronic renal disease and tetany (intermittent muscular contractions or spasms). It is not intended for use in Point of Care setting.
FDA Recall
Terminated
·SEPPIM SAS ZONE INDUSTRIELLE SEES France·Product code CJY·September 4, 2013
VITROS Chemistry Products Ca Slides, GEN 29, REF/Product Code 145 0261, Unique Device Identifier No. 10758750009114 or 20758750009111, IVD -- Sales Unit: 300 slides/pack Product Usage: For in vitro diagnostic use only. VITROS Ca Slides quantitatively measure calcium (Ca) concentration in serum, plasma, and urine. Calcium measurements are used in the diagnosis and treatment of parathyroid disease, a variety of bone disorders, chronic renal disease and tetany (intermittent muscular contractions or spasms).
FDA Recall
Terminated
·Ortho-Clinical Diagnostics·Product code CJY·May 18, 2016
VITROS Chemistry Products Ca Slides; Catalog Number: 145 0261;
FDA Recall
Open, Classified
·Ortho-Clinical Diagnostics, Inc.·Product code CJY·July 9, 2025
Consult Diagnostics Eon Calcium Reagent For In-Vitro Diagnostic Use PN: 1429 For the quantitative measurement of calcium in plasma and serum
FDA Recall
Terminated
·Vital Diagnostics, Inc.·Product code CJY·August 29, 2013
Randox CALCIUM (Ca) COLORIMETRIC METHOD RX DAYTONA PLUS Cat. No. CA 8309 R1, Arsenazo Reagent 4 x 20 ml GTIN: 05055273208368
FDA Recall
Terminated
·Randox Laboratories Ltd.
55 Diamond Road
Crumlin (North) Ireland·Product code CJY·December 4, 2018
Randox CALCIUM (Ca) Colorimetric Method RX Series Cat. No. CA 3871, R1. Arsenazo Reagent 9 x 51ml GTIN: 05055273200904
FDA Recall
Terminated
·Randox Laboratories Ltd.
55 Diamond Road
Crumlin (North) Ireland·Product code CJY·December 4, 2018
ORTHO CLINICAL DIAGNOSTICS INC VITROS CALCIUM (L-SEQUESTER) (300/PK) REAGENT.
FDA Recall
Open, Classified
·Mckesson Medical-Surgical Inc. Corporate Office
9954 Maryland Drive
Deep Run Iii Ste. 4000
Richmond VA 23233·Product code CJY·April 24, 2025
VITROS Chemistry Products Ca Slides packaged as 300 slides/pack catalog number 1450261 VITROS Ca Slides quantitatively measure calcium (Ca) concentration in serum, plasma, and urine using VITROS 250/350/950/5,1 FS and 4600 Chemistry Systems and the VITROS 5600 Integrated System.
FDA Recall
Terminated
·Ortho-Clinical Diagnostics·Product code CJY·June 12, 2013
Vital Diagnostics Envoy Calcium Reagent For In-Vitro Diagnostic Use. PN 55285 For the quantitative measurement of calcium in plasma and serum
FDA Recall
Terminated
·Vital Diagnostics, Inc.·Product code CJY·August 29, 2013
Milestone Wand STA Handpiece for the delivery of local anesthesia to dental tissue. Model Number STA-5050-305. The Wand STA handpiece is a single use syringe used in conjunction with the CompuDent STA computer controlled dental injection system.
FDA Recall
Terminated
·Milestone Scientific, Inc.·Product code EJI·February 11, 2015
Atellica CH Calcium_2 (CA_2), Siemens Material Number 11097644
FDA Recall
Open, Classified
·Siemens Healthcare Diagnostics, Inc.·Product code CJY·February 9, 2022
Psi Bands acupressure/acustimulation wrist bands in the following colors: Racer Black (UPC 859570001036), Daisy Chain (UPC 859570001029), Color Play (UPC 859570001043) and Cherry Blossom (UPC 859570001012).
FDA Recall
Terminated
·Psi Health Solutions·Product code MVV·April 26, 2007
Signature Ceramic Femoral Head. Model Number: 111-152-621. The Signature ceramic femoral heads are manufactured by Ceramtec from 72-75% Al2O3+24-26% Z3O3 (Biolox Delta). The heads connect via a 12/14 taper to the stem trunnion, and articulates against the crosslinked UHMWPE liner within the Logical Acetabular Cups. Product Usage: Components of the Signature Orthopaedics hip replacement range are intended to replace a hip joint where bone stock is sufficient to support the implant. When a surgeon has selected prosthetic replacement as the preferred treatment, the devices are indicated for: Non-inflammatory degenerative joint disease including osteoarthritis or avascular necrosis Inflammatory joint disease including rheumatoid arthritis Correction of functional deformity including congenital hip dysplasia Traumatic injury involving the hip joint including traumatic arthritis or femoral head or neck fracture Failed previous hip surgery including internal fixation or joint fusion, reconstruction, hemiarthroplasty, surface replacement, or total replacement
FDA Recall
Terminated
·Signature Orthopedics Pty Limited·Product code MEH·February 2, 2018
Ellex Solo LT5106-S ophthalmic laser (not sold in USA)
FDA Recall
Terminated
·Ellex Medical Pty Ltd·Product code HQF·February 15, 2011
Ellex Motorised Safety Filter, Zeiss; Model number 6339585. Intended for photocoagulation.
FDA Recall
Terminated
·Ellex Medical Pty Ltd·Product code HQF·February 11, 2009
Motorised Safety Filter, Wild; Model number 6339590. Intended for photocoagulation.
FDA Recall
Terminated
·Ellex Medical Pty Ltd·Product code HQF·February 11, 2009