33 results
·
19ms
·
Sources: EU EUDAMED, US FDA
Filters
FDA Recall
×
Turbo Elite 0.9mm Turbo Elite (TE) RX, Model #410-154, tip diameter 0.9mm/.038 in, 4 Fr, sterile EO. Manufactured by Spectranetics, 96 Talamine Court, Colorado Springs, CO 80907. The pouch label of the 1.4mm TE Over the Wire (OTW) catheter, Ref # 414-151, L/N# 080417D was incorrectly labeled for size as 0.9mm TE RX, Ref# 410-154, L/N#080417D. The box labels are correct and match the devices in the pouch. The Spectranetics TURBO-BoosterTM guiding catheter is designed for directing and supporting Spectranetics laser catheters for use in the treatment of infrainguinal stenoses and occlusions.
FDA Recall
Terminated
·Spectranetics Corporation·Product code MJQ·July 4, 2008
Hamilton brand Disposable Syringe Pack for use with Microlab F.A.M.E; Part Number: 147692 (case containing 96 syringes); Manufactured by: Treff AG, Degersheim, Switzerland for Hamilton Bonaduz AG, Bonaduz, Switzerland (Manufacturer of record); Product is distributed by Hamilton Company, Reno, NV The F.A.M.E Syringes are a disposable product that is used on our Microlab F.A.M.E. series instruments for diluting/dispensing. Microlab F.A.M.E was released under 510(k) K943493/S1 under product codes JJE (862.2160 Discrete Photometric Chemistry Analyzer for Clinical Use), JJQ (862.2300 Colorimeter, photometer, or spectrophotometer for Clinical Use), and JTC (866.2500 Microtiter Diluting/Dispensing Device), all of which are currently Class I exempt devices. The syringes are also used on Ortho Summit Processor instruments distributed by Ortho-Clinical Diagnostics.
FDA Recall
Terminated
·Hamilton Co·Product code JJE·September 26, 2011
GE Nuclear Medicine 600/800 series systems, specifically: a) 850, b) 850 / Dismount, c) 850 3/8 inch NM Gantry, d) 860 / Dismount, e) 860 3/8 inch NM Gantry, f) 860 5/8 inch NM Gantry, g) 860 BJ, h) NM 830 3/8 inch BJ, i) NM/CT 850 3/8 inch BJ, j) NM/CT 850 3/8 inch ROW, k) NM/CT 850 3/8 inch ROW_, l) NM/CT 850 CT 850 3/8 inch, m) NM/CT 850 ES 3/8 inch, n) NM/CT 850 ES 3/8 inch ROW, o) NM/CT 860 3/8 inch, p) NM/CT 860 3/8 inch BJ, q) NM/CT 860 3/8 inch ROW, r) NM/CT 860 ADVANCE, s) NM/CT 860 advance 3/8 inch NM Gantry, t) NM/CT 860 BEYOND, u) NM/CT 860 beyond 3/8 inch NM Gantry, v) NM/CT 860 China for China, w) NM/CT 860 CT 860 3/8 inch, x) NM/CT 860 ES 3/8 inch, y) NM/CT 860 ES 3/8 inch ROW, z) NM/CT 850 3/8 inch, aa) NM/CT 850 ES 3/8 inch ROW, bb) NM/CT 860 3/8 inch CH, cc) XELERIS 4 DR WORKSTATION; Emission Computed Tomography System
FDA Recall
Open, Classified
·GE MEDICAL SYSTEMS ISRAEL, FUNCTIONAL IMAGING 4, Hayozma St Tirat Carmel Israel·Product code KPS·December 19, 2022
CONSTELLATION ULTRAVIT 10K and CONSTELLATION HYPERVIT 20K, Description/REF: 25+ TOTALPLUS CP PAK 20K CPM BWV .9 IU/ 8065000093; 25+ TOTALPLUS CP PAK 20K CPM BV .9 IU/ 8065000095; 27+ TOTALPLUS CP PAK 20K CPM BV .9 IU/ 8065000096; 23GA BEVEL ULTRAVIT 10,000 CPM/ 8065752413; 25+ BEVEL ULTRAVIT 10,000 CPM/ 8065752415; 27+ BEVEL ULTRAVIT 10,000 CPM/ 8065752417; TOTAL PLUS,23G,10K VALVE STD/ 8065752435; TOTAL PLUS,23GA,10K VALVE WD/ 8065752436; TOTAL PLUS,25+,10K VALVE STD/ 8065752437; TOTAL PLUS,25+,10K VALVE WD/ 8065752438; TOTAL PLUS,27+,10K VALVE STD/ 8065752439; 23G CMB PAK 10K CPM,V,STD 0.9/ 8065752448; 23G CMB PAK 10K CPM,V,WA 0.9/ 8065752449; 25+ CMB PAK 10K CPM,V,STD 0.9/ 8065752450; 25+ CMB PAK 10K CPM,V,WA 0.9/ 8065752451; 27+ CMB PAK 10K CPM,V,STD 0.9/ 8065752452; 25+TTLPL VPK 20000CPM BEV VAL/ 8065753106; 27+TTLPL VPK 20000CPM BEV VL/ 8065753109; HYPERVIT 25+BEV 20000 CPM/ 8065830026; HYPERVIT 27+BEV 20000 CPM/ 8065830027; 25+ TTL PLUS VPAK 20000CPM BWV/ 8065830077; 25G VIT 25G OPTICARE EYE HLTH CTR/ 10924-15; VITRECTOMY 25G NORTHSIDE HOSP/ 11220-25; VITRECTOMY 25G NORTHSIDE HOSP/ 11220-27; 23G CONSTELLATION NORTHERN MICH SPPLY AL/ 12568-09; AUS-25GA VIT RET BRISBANE WATERS/ 12641-13; AUS-25GA VIT RET BRISBANE WATERS/ 12641-14; AUS-23GA 10K COMBINED VR PAK NEW CHILDRE/ 12852-16; 23G VIT CONSTELLATION LOMA LINDA COMM HO/ 13501-08; 25+G 20K VIT CONSTELLATION LOMA LINDA CO/ 13502-10; 23G VIT CONSTELLATION VALVED BAYSTATE ME/ 13591-13; 25G CONSTELLATION VALVED BAYSTATE MEDICA/ 13592-15; VITRECTOMY 25G V A HOSPITAL/ 14129-10; J-COMB PAK - 25G 20K CVS NAKAGAMI HOSPIT/ 14283-12; CDN-CVS VIT 25G VE 10K TIMMINS DH/ 14501-09; CDN-CVS VIT 25G+ VE 10K CIUSSS MCQ/ 14512-09; CDN-CVS VIT 25G+ VE 10K CIUSSS MCQ/ 14512-10; CDN-CVS VIT 23G 10K WA SASKATOON HR/ 14532-06; CDN-CVS VIT 23G 10K WA SASKATOON HR/ 14532-07; CDN-CVS VIT 10K 25G+ HSC, ST JOHN'S/ 14540-08; CDN-CVS COMBO 23G VE 10K HD KINGSTON/ 14541-16; CDN-CVS VIT 25G+ 20K BV JEWISH GH/ 14597-07; CDN-CVS VIT 23G 10K ROCKYVIEW HOSPITAL/ 14603-15; CDN-CVS COMBO 25G VE 10K TIMMINS DH/ 14669-10; CDN-CVS COMBO 25G VE 10K TIMMINS DH/ 14669-11; CDN-CVS VIT 23G VE ROYAL ALEXANDRA HOSP/ 14671-09; CDN-CVS VIT 25G+ 10K ROCKYVIEW HOSPITAL/ 14672-11; CDN-CVS VIT 25G+ BWV 20K CUSM/MUHC/ 14873-06; CDN-CVS VIT 25G+ BWV 20K CUSM-MUHC/ 14873-07; CDN-VIT 23G VE 10K ST MICHAEL'S HOSP/ 14955-08; CDN-VIT 23G VE 10K ST MICHAELS HOSP/ 14955-09; CDN-CVS 25G+ VIT VE 10K ST MICHAEL'S/ 14956-07; CDN-CVS 25G+ VIT VE 10K ST MICHAELS/ 14956-08; CDN-CVS VIT 25G+ 10K WESTERN MH/ 15006-06; CDN-CVS VIT 25G+ 20K WA WESTERN MH/ 15006-07; CDN-CVS COMBO 23G 10K ROCKYVIEW HOSPITAL/ 15108-09; CDN-CVS CMB 25G+ V 10K OAKVILLE-TRAFALGA/ 15167-08; 25G PLUS VITRECTOMY PEACE HEALTH ST JOSE/ 15223-13; CDN-VIT 23G 10K GRM741746 CUO-HSS/ 15294-14; CDN-COMBO 23G 10K GRM741759 CUO-HSS/ 15295-12; CDN-CVS VIT 25G+ VE 10K MISERICORDIA HC/ 15318-05; CDN-CVS VIT 25G+ VE 10K MISERICORDIA HC/ 15318-06; CDN-CVS VIT 25G+ VE 10K MISERICORDIA HC/ 15318-07; CDN-CVS COMBO 23G V 10K ST MICHAEL'S HSP/ 15324-07; CDN-COMBO 25G 20K GRM743287 CUO-HSS/ 15421-13; CDN-COMBO 25G 20K GRM743287 CUO-HSS/ 15421-14; CDN-UHN 23G COMBO VE 10K TORONTO WESTERN/ 15455-08; CDN-UHN 23G COMBO VE 10K TORONTO WESTERN/ 15455-09; CDN-UHN 23G COMBO VE 10K TORONTO WESTERN/ 15455-10; CDN-UHN 23G VIT VE 10K TORONTO WESTERN/ 15456-04; CDN-UHN 23G VIT VE 10K TORONTO WESTERN/ 15456-05; CDN-UHN 23G VIT VE 10K TORONTO WESTERN/ 15456-06; CDN-CVS 23G COMBO VE 10K SUNNYBROOK GH/ 15464-05; CDN-CVS 23G VIT VE 10K SUNNYBROOK GH/ 15465-05; 23G VIT PACK CALLAHAN EYE FOUNDATION HOS/ 15491-05; 23G VIT PACK CALLAHAN EYE FOUNDATION HOS/ 15491-06; 27G VIT PACK CALLAHAN EYE FOUNDATION HOS/ 15492-02; 27G VIT PACK CALLAHAN EYE FOUNDATION HOS/ 15492-03; 25G+ VIT PACK CALLAHAN EYE FOUNDATION HO/ 15493-05; 25G+ VIT PACK CALLAHAN EYE FOUNDATION HO/ 15493-06; CDN-CVS VIT 25G+ 10K PASQUA HOSPITAL/ 15525-04; CDN-CVS COMBO 23G VE 10K KENSINGTON EI/ 15552-05; CDN-CVS 23G VIT VE 10K KENSINGTON EYE IN/ 1
FDA Recall
Open, Classified
·Alcon Research LLC·Product code HQB·September 15, 2025
NucliSensEasy Q Incubator, Product Number 285204 (this number can be found at the back of the instrument).
FDA Recall
Terminated
·Biomerieux, Inc.·Product code JJQ·February 26, 2004
BD COR System Software. Model Number: 444829.
FDA Recall
Open, Classified
·Becton Dickinson & Co.·Product code MAQ·June 23, 2025
Hc2 System Software Suite 4.0 version 3.0, available as component in Qiagen user guide, catalog #5050-00162, and as a component within a Qiagen PC, available as catalog # 5050-11140A. The software calculates and interprets assay results generated by the Digene Microplate Luminometer according to assay validation parameters. The software is used in conjunction with the following QIAGEN products: digene HC2 High-Risk HPV DNA Test [5199-1220 (one-plate); 5199-00016 (four-plate)] digene HC2 HPV DNA Test (5198-1220) digene HC2 CT/GC DNA Test (5130-1220) digene HC2 CT-ID DNA Test (5135-1220) digene HC2 GC-ID DNA Test (5140-1220) digene HC2 CT-GC Dual-ID DNA Test (5145-1220)
FDA Recall
Terminated
·QIAGEN Gaithersburg, Inc.·Product code JJQ·January 12, 2011
Genuine One Touch Glucose 50 Test Strips, For the quantitative measure of glucose in whole blood, LIFESCAN, a Johnson & Johnson Company, Milpitas California 95035, For Sale Outside of the USA and Canada, Lot 1666680A Exp. 2003-11. Product is packed two vials of 25 strips per vial.
FDA Recall
Terminated
·Product code JJQ·October 8, 2002
INFORM HPV III Fam 16 Probe - US Export, Catalog Number 05278856001, model 800-4295 Immunohistochemistry (IHC) for in vitro diagnostic use.
FDA Recall
Terminated
·Ventana Medical Systems Inc·Product code MAQ·August 2, 2018
Tecan Infinite 200. The SUNRISE instrument is a 96-well absorbance reader for the measurement of light absorbance (optical density) of liquid media. The instrument is intended to be used primarily in in-vitro diagnostic analysis of samples from the human body to obtain information on physiological and pathological states. For applications in human clinical diagnostic uses, only the Magellan Tracker software is intended for the use with the instrument. Software and instrument have been validated for measurement and for the evaluation of qualitative and quantitative Enzyme-linked Immunosorbent Assays (ELISA) according to the scheduled diagnostic parameters and instrument specifications; they are therefore for professional use in in-vitro diagnostics.
FDA Recall
Terminated
·Tecan US, Inc.·Product code JJQ·July 25, 2016
Abbott Alinity m HPV AMP Kit, used with the Alinity m System, product codes: a) REF 09N15-095; b) REF 09N15-090; c) REF 09N15-091
FDA Recall
Open, Classified
·Abbott Molecular, Inc.·Product code MAQ·September 12, 2024
BD Veritor Connect Software, labeled as the following: 1. Veritor (NUC), Catalog Number: 444881. Transfers in vitro diagnostic results data on the BD Veritor Plus Analyzer to BD Synapsys.
FDA Recall
Open, Classified
·Becton Dickinson & Co.·Product code JJQ·September 23, 2025
Digene''s Hybrid Capture 2 HPV DNA Test, Catalog # 5196-1230, labeled for export only.
FDA Recall
Terminated
·Digene Corp·Product code MAQ·February 7, 2003
SureStep 50 Test Strips, For the measurement of glucose in whole blood, Two bottles of 25 Test Srips, LIFESCAN, a Johnson & Johnson Company, Milpitas, CA 95035, USA, Lot: E-169380A, Exp: 2003-01.
FDA Recall
Terminated
·Product code JJQ·October 8, 2002
MicroScan autoSCAN-4 Instrument, Catalog Number B1018-280
FDA Recall
Open, Classified
·Beckman Coulter, Inc.·Product code JJQ·October 3, 2022
Coulter DNA Prep Reagents Kit Part 6607055
FDA Recall
Terminated
·Beckman Coulter Inc·Product code MAQ·October 10, 2003
Hybrid Capture 2 High-Risk HPV DNA Test, Catalog # 5101-1296
FDA Recall
Terminated
·Digene Corp·Product code MAQ·February 7, 2003
Tecan Infinite M1000 PRO The Tecan Infinite M1000 PRO is a multifunctional monochromator-based microplate reader that provides high performance for the vast majority of todays microplate applications and research. In addition to offering absorbance and fluorescence intensity measurements, the Infinite M1000 PRO can also perform fluorescence polarization and luminescence measurements (including luminescence scans) as well as Amplified Luminescent Proximity Homogeneous Assays (AlphaScreen and AlphaLISA). The Infinite M1000 PRO is also robotic compatible and offers a built-in stacker option as well as an external injector module. The Infinite M1000 PRO is intended as a general purpose laboratory instrument for professional use, supporting common microplates conforming to the ANSI/SBS standards.
FDA Recall
Terminated
·Tecan US, Inc.·Product code JJQ·July 25, 2016
BD COR PX Instrument Version or Model: 443988 Catalog Number: 443988
FDA Recall
Open, Classified
·Becton Dickinson & Co.·Product code MAQ·October 31, 2024
The cobas z 480 analyzer including dedicated software for IVD use is a plate-based automated amplification and detection system for nucleic acids. The analyzer is intended to be used as an in-vitro diagnostic or screening system providing real time PCR amplification and detection for human samples within the system. The cobas x 480 instrument and cobas z 480 analyzer are to be used by laboratory professionals trained in laboratory techniques and by instruction on the use of the system and analyzer. In the U.S. the cobas z 480 analyzer is used for automated amplification and detection purposes for the following assays: cobas 4800 BRAF V600 Mutation Test cobas Cdiff Test for use on the cobas 4800 System cobas CT/NG v2.0 Test cobas EGFR Mutation Test v2 cobas Factor II and Factor V Test cobas 4800 HPV Test cobas HSV 1 and 2 Test for use on the cobas 4800 System cobas KRAS Mutation Test cobas MRSA/SA Test for use on the cobas 4800 System
FDA Recall
Terminated
·Roche Molecular Systems, Inc.·Product code MAQ·November 19, 2020