AquaBeam Handpiece, Sterile EO, Rx Only, REF: 310301, and 320301, a component of AquaBeam Robotic System. 320301 distributed outside the U.S. Device Description The AQUABEAM Robotic System is intended for use in patients suffering from lower urinary tract symptoms resulting from benign prostatic hyperplasia (BPH).
FDA Recall
Terminated
·PROCEPT BIOROBOTICS CORPORATION·Product code PZP·March 6, 2019
Seattle PAP Plus, MP02260
FDA Recall
Terminated
·Draeger Medical, Inc.·Product code BZD·April 17, 2023
ST-AIA PACK PAP; Part Number: 025262 Assay, Prostate
FDA Recall
Terminated
·Tosoh Bioscience Inc·Product code JFH·March 5, 2018
ELITech Clinical Systems reagents used on the Selectra ProS and ProM systems that utilize the Trinder Reaction method. The following product reference numbers and names: GPSL-025O: Glucose PAP SL AUML-0250: URIC ACID MONO SL CHSL-0250: CHOLESTEROL SL, TGML-0250: TRIGLYCERIDES SL, CRSL-0250: CREATININE PAP SL HDLL-0230: CHOLESTEROL HDL SL 2G LDLL-0230: CHOLESTEROL LDL SL 2G
FDA Recall
Terminated
·ELITech Clinical Systems SAS Zone lndustrielle SEES France·Product code CGA·September 22, 2015
Babi.Plus Bubble PAP Valve with 12.5 cm H2O Pressure Relief Manifold, REF 1002, Rx Only, UDI: 24710810093559
FDA Recall
Terminated
·Galemed Corporation 87 Wu-Jia Li-Gong 2nd Road I-Lan Taiwan·Product code BZD·May 30, 2019
*** 1) Product labeled in part: 19683-28; LIFESHIELD; MICRODRIP SOLUSET WITH 1.2 MICRON FILTER 150ML BURETTE PLUMSET, CONVERTIBLE PIN, CLAVE SECONDARY PORT, OPTION-LOK, NON-DEHP; NOMINAL LENGTH: 118 IN; PRIMING VOLUME: 14 ML; *** 2) Product labeled in part: List No. 19685-28; LifeShield; LATEX-FREE; PLUMSET, PRIMARY CONVERTIBLE PP W/ SIGHT CHAMBER, THREE WAY STOPCOCK, CLAVE INJECTION PORTS, OPTION-LOK, NON-DEHP; NOMINAL LENGTH: 136 IN (345 CM); PRIMING VOLUME: 24 ML; *** 3) Product labeled in part: 19720-28; LIFESHIELD; PLUM SET, CONV P.P, DUAL CHANNEL 3 CLAVE PORTS,IN LINE CHECK VAL OPTION LOK, NON-DEHP.; NOMINAL LENGTH:145 IN (368 CM); PRIMING VOLUME:13 ML; *** 4) Product labeled in part: 19721-28; LIFESHIELD; SOLUSET 150ML BUR,CONV P.P DUAL CHANNEL 4 CLAVE PORTS IN LINE CHECK VAL OPTION LOK, NON-DEHP; NOMINAL LENGTH: 145 IN (368 CM); PRIMING VOLUME: 15 ML: *** 5) Product labeled in part: 19729-28; LIFESHIELD; CONV. DUAL CHANNEL PLUMSET WITH CLAVES, AND SECURE LOK, NON-DEHP; NOMINAL LENGTH: 96 IN (244 CM); PRIMING VOLUME: 18 ML; *** 6) Product labeled in part: 19732-28; LIFESHIELD; LIFESHIELD LATEX-FREE PLUM SET,MICRODRIP,PP CHECK VALVE AND CLAVE OPTION-LOK, NON-DEHP; NOMINAL LENGTH:104 IN (264 CM); PRIMING VOLUME: 13 ML; Product Usage: The CLAVE of the secondary port is used as an easy secondary access that allows concurrent and piggyback mode in infusion. It is normally used with a syringe or a secondary IV infusion set.
FDA Recall
Terminated
·Hospira Inc.·Product code FPA·September 9, 2013
Cholesterol CHOD-PAP. In vitro diagnostic reagent system intended for use on the Hitachi systems for The quantitative determination of total cholesterol in serum and plasma.
FDA Recall
Terminated
·Roche Diagnostics Operations, Inc.·Product code CHH·May 7, 2015
LifeShield Latex-free Primary I.V. Set, convertible P.P. yellow key slide clamp, backcheck valve, 4 Clave ports, piggyback with Option-Loc, attached extension set, 122 inch, 15 drops/mL; an Rx sterile single use fluid path way for administration of I.V. fluids; 48 sets per case; Hospira, Inc., Lake Forest, IL 60045 USA, Made in Costa Rica; list number 19689-01
FDA Recall
Terminated
·Hospira Inc.·Product code FPA·January 8, 2010
ABX PENTRA Glucose PAP CP ref. A11A01668 reagent is intended for the quantitative in vitro diagnostic determination of glucose in human serum, plasma and urine using glucose oxidase method by colorimetry.
FDA Recall
Terminated
·Horiba Instruments Inc·Product code CFR·January 11, 2016
Human Assayed Multi-Sera Level 2, Model NO. HN1530 Product Usage: This product is intended for in vitro diagnostic use, in the quality control of diagnostic assays. The Human Assayed Multi-sera is for the control of accuracy.
FDA Recall
Terminated
·Randox Laboratories, Limited Ardmore; 55 The Diamond Road Crumlin United Kingdom·Product code JJY·June 11, 2019
ADVIA Alanine Aminotransferase (ALT) reagent chemistry assays; ALT intended to measure the activity of the enzyme alanine amino transferase (ALT) (also known as a serum glutamic pyruvic transaminase or SGPT) in serum and plasma. (Product Numbers: 10318168, 10309500), ALT P5P (Part Numbers: 10318168/10326245, 10309500/10315181), and ALT Concentrated (Part Numbers: 10283341, 10283341, 10283342); (Mfr: Randox Laboratories)
FDA Recall
Terminated
·Siemens Healthcare Diagnostics, Inc.·Product code CKA·June 29, 2017
*** 1) Product labeled in part: 14951-48; LIFESHIELD; PLUMSET WITH CONVERTIBLE PIERCING PIN, TWO INTEGRAL CLAVE PORTS AND CLAVE ON SECONDARY PORT; NOMINAL LENGTH: 104 IN (264 CM); PRIMING VOLUME: 19 ML; *** 2) Product labeled in part: 14952-01; LIFESHIELD; HEMA Y-TYPE BLOOD PLUMSET, NONVENTED WITH 210 MICRON FILTER AND OPTION-LOK, DUAL CHANNEL, CLAVE SECONDARY PORT; NOMINAL LENGTH: 102 IN (260 CM); PRIMING VOLUME: 69 ML; *** 3) Product labeled in part: 14954-28; LIFESHIELD; LIFECARE 5000 WITH PROXIMAL 0.2 MICRON FILTER-0L, CONVERTIBLE PIN, DUAL CHANNEL, INTEGRAL Y CLAVE, NON-DEHP; NOMINAL LENGTH: 112 IN (284 CM); PRIMING VOLUME: 24 ML; *** 4) Product labeled in part: List No. 19553-12; LifeShield; LATEX-FREE; PLUM EXTENSION SET WITH CLAVE SECONDARY PORT; NOMINAL LENGTH: 28 IN (71 CM); PRIMING VOLUME: 7.1 ML; SET CONTAINS DEHP; *** 5) Product labeled in part: 19556-28; LIFESHIELD; PLUMSET HEMOSET 100 ML BURETTE, DUAL CHANNEL CASSETTE WITH CLAVE, SECURE LOCK, NON-DEHP NOMINAL LENGTH: 98 IN (249 CM); PRIMING VOLUME: 17 ML; *** 6) Product labeled in part: 19557-28; LIFESHIELD; PLUMSET CONVERTIBLE PIN, TWO INTEGRAL CLAVES, CLAVE SECONDARY PORT AND OPTION LOK, NON-DEHP; NOMINAL LENGTH: 110 IN (279 CM); PRIMING VOLUME: 21.4 ML; *** 7) Product labeled in part: 19671-28; LIFESHIELD; CONVERTIBLE PP LIFECARE 5000 CASSETTE W/CLAVE MICRODRIP SOLUSET 150 X 60 DPM, CLAVE INJECTION SITE, NON DEHP; NOMINAL LENGTH: 124 IN (315 CM); PRIMING VOLUME: 13 ML; *** 8) Product labeled in part: 19683-28; LIFESHIELD; MICRODRIP SOLUSET WITH 1.2 MICRON FILTER 150ML BURETTE PLUMSET, CONVERTIBLE PIN, CLAVE SECONDARY PORT, OPTION-LOK, NON-DEHP; NOMINAL LENGTH: 118 IN; PRIMING VOLUME: 14 ML; *** 9) Product labeled in part: List No. 19685-28; LifeShield; LATEX-FREE; PLUMSET, PRIMARY CONVERTIBLE PP W/ SIGHT CHAMBER, THREE WAY STOPCOCK, CLAVE INJECTION PORTS, OPTION-LOK, NON-DEHP; NOMINAL LENGTH: 136 IN (345 CM); PRIMING VOLUME: 24 ML; USA; *** 10) Product labeled in part: 19720-28; LIFESHIELD; PLUM SET, CONV P.P, DUAL CHANNEL 3 CLAVE PORTS,IN LINE CHECK VAL OPTION LOK, NON-DEHP.; NOMINAL LENGTH:145 IN (368 CM); PRIMING VOLUME:13 ML; *** 11) Product labeled in part: 19721-28; LIFESHIELD; SOLUSET 150ML BUR,CONV P.P DUAL CHANNEL 4 CLAVE PORTS IN LINE CHECK VAL OPTION LOK, NON-DEHP; NOMINAL LENGTH: 145 IN (368 CM); PRIMING VOLUME: 15 ML: *** 12) Product labeled in part: 19729-28; LIFESHIELD; CONV. DUAL CHANNEL PLUMSET WITH CLAVES, AND SECURE LOK, NON-DEHP; NOMINAL LENGTH: 96 IN (244 CM); PRIMING VOLUME: 18 ML; *** 13) Product labeled in part: 19732-28; LIFESHIELD; LIFESHIELD LATEX-FREE PLUM SET,MICRODRIP,PP CHECK VALVE AND CLAVE OPTION-LOK, NON-DEHP; NOMINAL LENGTH:104 IN (264 CM); PRIMING VOLUME: 13 ML; Product Usage: The CLAVE of the secondary port is used as an easy secondary access that allows concurrent and piggyback mode in infusion. It is normally used with a syringe or a secondary IV infusion set.
FDA Recall
Terminated
·Hospira Inc.·Product code FPA·September 9, 2013
BD FocalPoint Slide Profiler and BD FocalPoint GS Review Station; Catalog Nos. 490398, 490653, 491085, 491086, 491090, 490189 The BD FocalPoint GS Imaging System is intended to assist in cervical cancer screening of BD SurePath Liquid-based Pap Test slides to detect evidence of squamous carcinoma, adenocarcinoma and their usual precursor conditions.
FDA Recall
Terminated
·Becton Dickinson & Co. 7 Loveton Cir BD Diagnostic Systems·Product code MNM·September 21, 2018
KIT cobas 4800 HPV AMP/DET 240T / 960T US-IVD, CE-IVD Roche Molecular System, Inc. 1080 US highway 202 South Branchburg, NJ 08876 USA Roche Diagnostics 9115 Hague Road Indianapolis, IN 46250-0457 USA The cobas HPV Test is a qualitative in vitro test for the detection of Human Papillomavirus in patient specimens. The test utilizes amplification of target DNA by the Polymerase Chain Reaction (PCR) and nucleic acid hybridization for the detection of 14 high-risk (HR) HPV types in a single analysis. The test specifically identifies types HPV16 and HPV18 while concurrently detecting the rest of the high risk types (31, 33, 35, 39, 45, 51, 52, 56, 58, 59, 66 and 68). The cobas HPV Test is indicated: (a) To screen patients 21 years and older with ASC-US (Atypical squamous cells of undetermined significance) cervical cytology test results to determine the need for referral to colposcopy. (b) To be used in patients 21 years and older with ASC-US cervical cytology results, to assess the presence or absence of high-risk HPV genotypes 16 and 18. This information, together with the physicians assessment of cytology history, other risk factors, and professional guidelines, may be used to guide patient management. The results of this test are not intended to prevent women from proceeding to colposcopy. (c) In women 30 years and older, the cobas HPV Test can be used with cervical cytology to adjunctively screen to assess the presence or absence of high risk HPV types. This information, together with the physicians assessment of cytology history, other risk factors, and professional guidelines, may be used to guide patient management. (d) In women 30 years and older, the cobas HPV Test can be used to assess the presence or absence of HPV genotypes 16 and 18. This information, together with the physicians assessment of cytology history, other risk factors, and professional guidelines, may be used to guide patient management. Cervical specimens that may be tested with the cobas HPV Test include the following liquid based collection media and collection device: " ThinPrep Pap TestTM PreservCyt Solution " Endocervical Brush/Spatula
FDA Recall
Terminated
·Roche Molecular Systems, Inc.·Product code MAQ·July 25, 2013
Weck Hem-o-lok XL Polymer Ligating Clips; Rx, sterile, extra large size, non-absorbable polymer ligation clips; 6 clips per cartridge, 14 cartridges per sales unit, 12 sales units per case; Mfg. by Weck Closure Systems, Research Triangle Park, NC 27709; REF 544250
FDA Recall
Terminated
·Teleflex Medical·Product code FZP·April 12, 2006
Weck Hemoclip Traditional Ligating Clips, Rx Only, Sterile, Teleflex Medical, RTP, NC 27709 USA. The use of the reusable Teleflex Medical metal ligating clips is transient, invasive and intended for the application of hemostatic clips during general open surgery. Ligation clips are non-absorbable to thermostatically restrict flow of fluids within vessels. Clips are removed from the cartridge and applied in such a manner as to engulf vessels. Teleflex Medical metal ligating clips are intended for use in procedures involving vessels or anatomic structures for which the surgeon determines ligating clips are the best choice. Surgeons should select the size type, and material of the clip based upon their experience, judgment and needs.
FDA Recall
Terminated
·Telefelx Medical·Product code FZP·August 22, 2008
Weck , Horizon Titanium Clips, Rx Only, Sterile, Teleflex Medical, RTP, NC 27709, USA. The use of the reusable Teleflex Medical metal ligating clips is transient, invasive and intended for the application of hemostatic clips during general open surgery. Ligation clips are non-absorbable to thermostatically restrict flow of fluids within vessels. Clips are removed from the cartridge and applied in such a manner as to engulf vessels. Teleflex Medical metal ligating clips are intended for use in procedures involving vessels or anatomic structures for which the surgeon determines ligating clips are the best choice. Surgeons should select the size type, and material of the clip based upon their experience, judgment and needs.
FDA Recall
Terminated
·Telefelx Medical·Product code FZP·August 22, 2008
Weck Hemoclip Plus Ligating Clips, Rx Only, Sterile, Teleflex Medical, RTP, NC 27709 USA. The use of the reusable Teleflex Medical metal ligating clips is transient, invasive and intended for the application of hemostatic clips during general open surgery. Ligation clips are non-absorbable to thermostatically restrict flow of fluids within vessels. Clips are removed from the cartridge and applied in such a manner as to engulf vessels. Teleflex Medical metal ligating clips are intended for use in procedures involving vessels or anatomic structures for which the surgeon determines ligating clips are the best choice. Surgeons should select the size type, and material of the clip based upon their experience, judgment and needs.
FDA Recall
Terminated
·Telefelx Medical·Product code FZP·August 22, 2008
WECK HemoClip Auto, Rx Only, Sterile, Teleflex Medical, RTC, NC 27709. The use of the reusable Teleflex Medical metal ligating clips is transient, invasive and intended for the application of hemostatic clips during general open surgery. Ligation clips are non-absorbable to thermostatically restrict flow of fluids within vessels. Clips are removed from the cartridge and applied in such a manner as to engulf vessels. Teleflex Medical metal ligating clips are intended for use in procedures involving vessels or anatomic structures for which the surgeon determines ligating clips are the best choice. Surgeons should select the size type, and material of the clip based upon their experience, judgment and needs.
FDA Recall
Terminated
·Telefelx Medical·Product code FZP·August 22, 2008
Medtronic SPYDER Anastomotic Device. Sterilized using irradiation. Do not Reuse. Nonpyrogenic. The SPYDER is designed to create an anastomosis in a rapid, automated fashion. The device creates an interrupted anastomosis without the need for aortic clamping. A specially designed aortic cutting device (ACD) (sold separately) is utilized to create the site for the anastomosis.
FDA Recall
Terminated
·Medtronic Cardiac Surgery Technologies·Product code FZP·September 1, 2005