33 results
·
42ms
·
Sources: EU EUDAMED, US FDA
Filters
FDA Enforcement
×
Arena-L 35x26 Trial Head I 10¿ Lordotic; Part: 11-81004-08, 11-81004-10, 11-81004-12, 11-81004-14, 11-81004-16 The trial heads are smooth plates that mimic the footprint of the implant, manufactured from 17-4 Stainless Steel into 35X26mm (11-81004-XX) and 38X28mm (11-81012-XX) varieties, each with multiple height configurations. The Trial Heads are intended to attach tot he Trial Handle (11-81002) and to be inserted into the intervertebral disc space. The Trial Handle consists of a knurled handle and cylindrical shaft with an M4 threads interface at the distal end; 17-4 Stainless steel is used as the material for the handles. The Trial Heads distract the disc space to the surgeon's desired height to gauge which size implant should be utilized to complete the Anterior Lumbar Interbody Fusion Procedure.
FDA Enforcement
Class II
·Terminated·SpineFrontier, Inc.·January 22, 2014
PedFuse Bone Probe; Part: SI81008 spinal pedicle fixation.
FDA Enforcement
Class II
·Terminated·SpineFrontier, Inc.·January 15, 2014
Arena-L Trial Handle; Part: 11-81002 The trial heads are smooth plates that mimic the footprint of the implant, manufactured from 17-4 Stainless Steel into 35X26mm (11-81004-XX) and 38X28mm (11-81012-XX) varieties, each with multiple height configurations. The Trial Heads are intended to attach tot he Trial Handle (11-81002) and to be inserted into the intervertebral disc space. The Trial Handle consists of a knurled handle and cylindrical shaft with an M4 threads interface at the distal end; 17-4 Stainless steel is used as the material for the handles. The Trial Heads distract the disc space to the surgeon's desired height to gauge which size implant should be utilized to complete the Anterior Lumbar Interbody Fusion Procedure.
FDA Enforcement
Class II
·Terminated·SpineFrontier, Inc.·January 22, 2014
S-LIFT Extension Shims Extension shims are manufactured from grade 5 titanium and are curved, rectangular slabs which have four protrusions used for ratcheting. They come in straight and pointed varieties, either with or without a tab containing an additional bend. Extension shims are designed to slide down retractor blades, and are optional retractor components utilized during lumbar interbody fusion procedures. They are intended to manipulate tissue and prevent tissue from interfering inside the surgical field.
FDA Enforcement
Class II
·Terminated·SpineFrontier, Inc.·November 20, 2013
Arena-L 38x28Trial Head I 10¿ Lordotic; Part: 11-81012-08, 11-81012-10, 11-81012-12, 11-81012-14 The trial heads are smooth plates that mimic the footprint of the implant, manufactured from 17-4 Stainless Steel into 35X26mm (11-81004-XX) and 38X28mm (11-81012-XX) varieties, each with multiple height configurations. The Trial Heads are intended to attach tot he Trial Handle (11-81002) and to be inserted into the intervertebral disc space. The Trial Handle consists of a knurled handle and cylindrical shaft with an M4 threads interface at the distal end; 17-4 Stainless steel is used as the material for the handles. The Trial Heads distract the disc space to the surgeon's desired height to gauge which size implant should be utilized to complete the Anterior Lumbar Interbody Fusion Procedure
FDA Enforcement
Class II
·Terminated·SpineFrontier, Inc.·January 22, 2014
SpineFrontier MISquito Percutaneous Pedicle Screw System Surgical Technique; Part Number: DOC80023. The Rod Caliper is a manual surgical instrument that may be used as part of the PedFuse Pedicle Screw System and its MISquito components during percutaneous, minimally invasive surgical (MIS) technique of posterior pedicle screw fixation.
FDA Enforcement
Class II
·Terminated·SpineFrontier, Inc.·April 29, 2015
lnline Persuader- PedFuse Pedicle Screw System; Part Number: 11-80164
FDA Enforcement
Class II
·Terminated·SpineFrontier, Inc.·January 21, 2015
Invue Solid Driver, Tipped, AO. Part Number: 11-70083. Allows the user to retain the screw when changing axis of insertion during fixation of spinal intervertebral.
FDA Enforcement
Class II
·Terminated·SpineFrontier, Inc.·August 21, 2013
Case Lid and Base (Inspan, Invue, SLIFT) Caddy Lid (Inspan, Arena-C); Inspan Lid: 12-60039A, 11-60042B, 11-60043B, 11-60045B, 11-60046C, 11-60045A, 11-60046A, 11-60053A; Invue Lid: SI70095A; S-Lift Lid: SI50070A; S-Lift Base: SI50067A; Arena-C Lid: 11-72013D, 11-72014D; Generics Lid: 12-99005A. System cases are designed to hold and secure all instrumentation to be used with a surgical system.
FDA Enforcement
Class II
·Terminated·SpineFrontier, Inc.·August 21, 2013
Drill Guide - Chameleon FacetFuse Fixation System, Model: 11-00028 Rev. A FacetFuse Drill Guides were designed to provide a concentric pathway for the drills and taps to access the bone while protecting the soft tissue from the cutting geometry of the drills/taps. In addition the drill guide is used as a reference to measure depth that the drills and taps are protruding into bone, which is measured by depth markings at the proximal end of the drills/taps relative to the proximal end of the drill guide. These devices were used during implantation of spinal intervertebral body fusion devices intended for intervertebral body fusion of the spine of skeletally mature patients.
FDA Enforcement
Class II
·Terminated·SpineFrontier, Inc.·August 14, 2013
PedFuse Reset Screw Inserters; PedFuse Screw Inserter 08-9 REset Part# 11-80113 The PedFuse Screw Inserter 05-7 REset, Screw Inserter 05-7 REspond, and Screw Inserter 08-9 REset are used as a screw capture, screw driver, and screw insertion tool in the PedFuse system.
FDA Enforcement
Class II
·Terminated·SpineFrontier, Inc.·January 1, 2014
InSpan Inserter, Right Assembly; InSpan Inserter, Left Assembly Product Usage: Inserters are stainless steel instruments that have an inner shaft. The left and right inserters are used in combination with each other to place the implants into the body. Inserters are used to install the InSpan Spinous Plate System for the purpose of achieving supplemental fixation.
FDA Enforcement
Class II
·Terminated·SpineFrontier, Inc.·July 10, 2013
T-Handle, Strike Plate, Push Connection, Part Number: SI50023 Rev A T-handles are silicone handled instruments that have a quick release end. The silicone T-handle has an impactor cap on the proximal end of the handle which is designed to be struck with a mallet. T-handles are used primarily to attach to, and operate a wide range of instruments used during implantation of spinal intervertebral body fusion devices intended for intervertebral body fusion of the spine of skeletally mature patients.
FDA Enforcement
Class II
·Terminated·SpineFrontier, Inc.·August 14, 2013
BASE, S-LIFT Instrument Case Product Usage: System cases are designed to hold and secure all instrumentation to be used with a surgical system. Case and caddy components are used to contain implants intended for intervertebral body fusion and fixation of the spine.
FDA Enforcement
Class II
·Terminated·SpineFrontier, Inc.·July 10, 2013
PedFuse Reset Screw; Model: 01-80115-55 The PedFuse Reset pedicle screw implants intended to be used to help provide immobilization and stabilization of spinal segments as an adjunct to fusion of the thoracic, lumbar, and/or sacral spine.
FDA Enforcement
Class II
·Terminated·SpineFrontier, Inc.·December 25, 2013
Indus Invue Screws: IM71013-XX: Indus Screw04.0mm SelfDrilling. Used to secure the Invue Anterior Cervical Plate in position.
FDA Enforcement
Class II
·Terminated·SpineFrontier, Inc.·January 1, 2014
Indus Invue Screws: lM71059-XX: Indus Screw 04.2mm SelfDrilling. Used to secure the Invue Anterior Cervical Plate in position.
FDA Enforcement
Class II
·Terminated·SpineFrontier, Inc.·January 1, 2014
PedFuse Reset Screw Inserters; PedFuse Screw Inserter 05-7 REspond Part# 11-80111 The PedFuse Screw Inserter 05-7 REset, Screw Inserter 05-7 REspond, and Screw Inserter 08-9 REset are used as a screw capture, screw driver, and screw insertion tool in the PedFuse system.
FDA Enforcement
Class II
·Terminated·SpineFrontier, Inc.·January 1, 2014
KRD1 PedFuse Rods, Model: IM80100-13 Rev B Product Usage: Pedicle rods are cylindrical rods which act as a linking mechanism between pedicle screws. The rod sits with the pedicle screw tulip and they are locked into place with a set screw or locking cap. The rod may be placed along several pedicle screws. Component rods are used during implantation of pedicle screw system devices intended to provide immobilization and stabilization of spinal segments of skeletally mature patients.
FDA Enforcement
Class II
·Terminated·SpineFrontier, Inc.·July 24, 2013
Caddy - PedFuse, Screw Caddy, 8MM and 9MM, Part Number: 11-80009 Rev. B The caddy holds, in an organized fashion within the case, 8mm and 9mm pedicle screws used during implantation of pedicle screw system devices intended to provide immobilization and stabilization of spinal segments of skeletally mature patients
FDA Enforcement
Class II
·Terminated·SpineFrontier, Inc.·August 7, 2013