64 results · 58ms · Sources: EU EUDAMED, US FDA

Get notified when this changes

We'll email you when new records match this search — new devices, new clearances, certificate changes, or withdrawals.

MAKO SURGICAL CORPORATION UNICONDYLAR KNEE IMPLANT SYSTEM III

FDA 510(k)
FDA Class 2 ·Orthopedic

MAKO SURGICAL CORPORATION

FDA Adverse Event
Injury ·MAKO SURGICAL CORPORATION·Product code OLO·October 17, 2011

RESTORIS PST Acetabular Straight Shell Impactors An impactor is a reusable instrument designed for use by orthopedic surgeons specifically for the purpose of positioning and implanting acetabular cup components during Total Hip Arthroplasty (THA) surgery.

FDA Recall
Terminated ·Mako Surgical Corporation·Product code OLO·October 7, 2014

RESTORIS PST Acetabular Offset Shell Impactors An impactor is a reusable instrument designed for use by orthopedic surgeons specifically for the purpose of positioning and implanting acetabular cup components during Total Hip Arthroplasty (THA) surgery.

FDA Recall
Terminated ·Mako Surgical Corporation·Product code OLO·October 7, 2014

RESTORIS PST Straight Shell Inserter An impactor is a reusable instrument designed for use by orthopedic surgeons specifically for the purpose of positioning and implanting acetabular cup components during Total Hip Arthroplasty (THA) surgery.

FDA Recall
Terminated ·Mako Surgical Corporation·Product code OLO·October 7, 2014

Tibial Array and Femoral Array. Model Number(s): 0150ARR00001 and 0150ARR00002. Manufactured by: MAKO Surgical, Corp. The devices are accessories used with MAKO's Tactile Guidance System (TGS). The Tactile Guidance System is intended to assist the surgeon in providing software defined spatial boundaries for orientation and reference information to anatomical structures during orthopedic procedures.

FDA Recall
Terminated ·Mako Surgical Corporation·Product code HAW·May 2, 2008

The RIO (TGS 2.), Model # MAKO TGS 2.0 (Part No. 204000). The RIO is intended to assist the surgeon in providing software defined spatial boundaries for orientation and reference information to anatomical structures during orthopedic procedures. The RIO is indicated for use in surgical knee and hip procedures, in which the use of stereotactic surgery may be appropriate, and where reference to rigid anatomical bony structures can be identified relative to a CT based model of the anatomy. These procedures include: Unicondylar knee replacement (UKA) and/or Patellofemoral knee replacement (PKA) and Total Hip Arthroplasty (THA).

FDA Recall
Terminated ·Mako Surgical Corporation·Product code OLO·September 12, 2012

Restoris Multicompartmental Knee (MCK) System is an implant system designed to be used with MAKO's Robotic Arm Interactive Orthopedic System (RIO). It is composed of a unicompartmental implant system (Restoris MCK Uni) and a patellofemoral implant system (Restoris MCK PF). The Restoris MCK Uni is designed for use when load bearing ROM is expected to be less than or equal to 155 degrees. In Restoris MCK combination where multi-compartmental areas are being treated, the Restoris MCK components were designed with 3 mm of gap between the components to ensure that the components do not interfere. Is indicated for single or multi-compartmental knee replacement used in conjunction with RIO, in individuals with osteoarthritis or post-traumatic arthritis of the tibiofemoral and/or patellofemoral articular surfaces.

FDA Recall
Terminated ·Mako Surgical Corporation·Product code NPJ·January 9, 2014

MAKO PN 204588 Camera 204588 Label With Camera Stand Number ***PN 200294 SN CAM XXX 2011-01.*** Weight 86.2kg.***Class I Equipment. Conforms to IEC 60601-1/A2: 1995, EN 60601-1/A2: 1995, UL 60601-1: 2003, CAN/CSA-C22.2 No. 601.1-M90.*** Manufactured in USA*** MAKO SURGICAL CORP. 2555 Davie Road, Ft. Lauderdale, FL 33317.*** 204589 Robot Arm Label***PN 203999 SN ROB XXX 2011-01.***V 100/120/230 A 9.6/8.0/4.2 Hz 50/60***Weight 39.4kg***Class I Equipment Conforms to IEC 60601-1/A2: 1995, EN 60601-1/A2: 1995, UL 60601-1:2003 CAN/CSA-C22.2 No. 601-1-M90.***Manufactured in USA***MAKO SURGICAL CORP. 2555 Davie Road, Ft. Lauderdale, FL 33317.*** 204588 Label With Guidance Module Number***PN 201251 SN GUD XXX 2011-01***Weight 51.7kg***Class I Equipment. Conforms to IEC 60601-1/A2: 1995, En 60601-1/A2: 1995, UL 60601-1: 2003, CAN/CSA-C22.2 No. 601.1-M90***Manufactured in USA***MAKO SURGICAL CORP. 2555 Davie Road, Ft. Lauderdale, FL 33317.*** THE RIO uses an infra-red camera for the purpose of spatial navigation. This camera is present on the Camera Stand and communicates with the Guidance Module to provide the locations of the tracked instruments (i.e. robotic-arm, patient trackers, probes, etc). The information is then used to provide the virtual representation of the patient anatomy and the tools on the monitor, and provides necessary information to the robotic-arm to ensure proper bone preparation.

FDA Recall
Terminated ·Mako Surgical Corporation·Product code KQM·October 25, 2010

200996-Cable Assembly, Hybrid Extended Length, 200997 Cable Assembly, Hybrid, Guidance Module, 200998 Cable Assembly, Hybrid, UI Panel Subcomponents for the 203000 RIO STANDARD SYSTEM Manufactured by: MAKO Surgical, Corp. Fort Lauderdale, FL. All three cables are integral components and are not purchased separately. However, 200996-Cable Assembly is the only cable visible. This cable is labeled: 200996-REV-1, KSM 390634-1, SN 000001. 200997 and 200998 Cable Assembly are not visible . The Tactile Guidance System v2.0 is intended to assist the surgeon in providing software defined spatial boundaries for orientation and reference information to anatomical structures during orthopedic procedures.

FDA Recall
Terminated ·Mako Surgical Corporation·Product code HAW·July 17, 2009

MAKO ROBOT INTEGRATED CUTTING SYSTEM

FDA Adverse Event
Malfunction ·MAKO SURGICAL CORPORATION·Product code OLO·April 9, 2021

MAKO HANDPIECE

FDA Adverse Event
Malfunction ·MAKO SURGICAL CORPORATION·Product code OLO·January 12, 2022

Restoris Multicompartmental Knee (MCK) System RESTORIS MCK is indicated for single or multi-compartmental knee replacement used in conjunction with RIO.

FDA Recall
Terminated ·Mako Surgical Corporation·Product code NPJ·January 15, 2016

MAKO RIO Standard System, internal cPCI Card CageP/N: 201337. Intended to assist the surgeon in providing software defined spatial boundaries during orthopedic procedures.

FDA Recall
Terminated ·Mako Surgical Corporation·Product code OLO·June 7, 2017

Mako Integrated Cutting System (MICS) Handpiece, Catalog Number 209063, Software Version#: THA 3.0 and later, PKA 3.0 and later, and TKA 1.0 - Product Usage: The MICS Handpiece is attached to the distal end of the robotic arm and is used to register the RIO (Mako robot) and to execute bone preparation during a Mako Total Knee or Mako Partial Knee procedure (PKA Software Application 3.0 or later).

FDA Recall
Completed ·Mako Surgical Corporation·Product code OLO·October 23, 2020

Robotic Arm Interactive Orthopedic (RIO) system component PN#205143 (locking pin) and PN# 112220 (connector). Indicated for use in surgical knee resurfacing and total hip Arthroplasty joint replacement procedures.

FDA Recall
Terminated ·Mako Surgical Corporation·Product code OLO·July 16, 2015

Robotic Arm Interactive Orthopedic System (RIO)

FDA Recall
Terminated ·Mako Surgical Corporation·Product code OLO·April 30, 2014

RESTORIS PST RIO Offset Shell Impactor For use by orthopedic surgeons specifically for the purpose of positioning and implanting acetabular cup components during Total Hip Arthroplasty (THA) surgery.

FDA Recall
Terminated ·Mako Surgical Corporation·Product code OLO·February 23, 2016

Stryker Restoris RIO Reamer Handle, Offset, Mako Rx only Product Usage: The handle is used to hold surgical components during acetabular reaming in MAKO Total Hip procedures.

FDA Recall
Terminated ·Mako Surgical Corporation·Product code OLO·September 29, 2016

Mako Hip End Effector, Variable Angle Catalog Number: 206967 GTIN:00848486022167

FDA Recall
Terminated ·Mako Surgical Corporation·Product code OLO·July 9, 2020