19 results · 23ms · Sources: EU EUDAMED, US FDA

Get notified when this changes

We'll email you when new records match this search — new devices, new clearances, certificate changes, or withdrawals.

lnvatec SpA brand Diver C.E., Model/Catalog Numbers: DVR010014145, DVR011014145, Product is manufactured by lnvatec SpA, Roncadelle, Italy, and distributed by Invatec, Inc., Bethlehem, PA and by Medtronic Endovascular Therapies, Santa Rosa, CA The Diver C.E. product is an aspiration catheter indicated for the removal of fresh, soft emboli and thrombi from vessels in the arterial system.

FDA Enforcement
Class II ·Terminated·Invatec Llc·June 12, 2013

Ovation Prime Abdominal Stent Graft System; Manufacturer: TriVascular, Inc. 3910 Brickway Blvd. Santa Rosa, CA 95403 The TriVascular Ovation Prime Abdominal Stent Graft System is an endovascular device delivered via a small diameter catheter to treat abdominal aortic aneurysms (AAAs). The stent graft is designed to reline the diseased vasculature, providing an endovascular blood conduit for isolating the aneurysm from the high pressure flow of blood, thereby reducing the risk of rupture. The stent graft is a modular configuration comprised of an aortic body section, iliac limbs, and iliac extensions as required.

FDA Enforcement
Class II ·Terminated·Trivascular, Inc·April 2, 2014

Acecide-C High Level Disinfectant & Sterilant 875 mL. Packaging is 6 inner cartons in one master carton;1 inner carton consists of a set of two liquids (1 acid & 1 buffer) banded together.

FDA Enforcement
Class II ·Terminated·Best Sanitizers Inc·September 14, 2016

Lumenis brand DuoTome SideLite 550 Micron Delivery System; laser systems for ablating soft tissue. Catalog Number: 0641-800-01; Manufactured by Lumenis, Inc., 2400 Condensa Street, Santa Clara, CA

FDA Recall
Terminated ·Lumenis Inc.·Product code GEX·August 29, 2006

Allez Medical Applications, Inc. 4Closure Surgical Fascia Closure System , Catalog ref. 4S. Sterile, One Time Use, Contents 4 sets 1- suture passer instrument. Distributed by Aliez Medical Applications, Inc., Santa Ana, CA 92707. Synovis over labels the "Distributed by....", For Customer Service Contact: Synovis Surgical Innovations 2575 University Ave W., St. Paul, MN 55114-1024

FDA Recall
Terminated ·Synovis Surgical Inovation Div. of·Product code GDF·June 19, 2007

Allez Medical Applications, Inc. 4Closure Surgical Fascia Closure System , Catalog ref. 4-23DG. Sterile, One Time Use, Contents 4 sets 1-guide rod, 23 mm, 250 mm long, dilating. Distributed by Aliez Medical Applications, Inc., Santa Ana, CA 92707. Synovis over labels the "Distributed by....", For Customer Service Contact: Synovis Surgical Innovations 2575 University Ave W., St. Paul, MN 55114-1024

FDA Recall
Terminated ·Synovis Surgical Inovation Div. of·Product code GDF·June 19, 2007

Allez Medical Applications, Inc. 4Closure Surgical Fascia Closure System , Catalgo ref. 4-12GPS. Sterile, One Time Use, Contents 4 sets 1- suture passer instrument, 1-guide rod, 12mm, 250 mm long. Distributed by Aliez Medical Applications, Inc., Santa Ana, CA 92707. Synovis over labels the "Distributed by....", For Customer Service Contact: Synovis Surgical Innovations 2575 University Ave W., St. Paul, MN 55114-1024

FDA Recall
Terminated ·Synovis Surgical Inovation Div. of·Product code GDF·June 19, 2007

Allez Medical Applications, Inc. 4Closure Surgical Fascia Closure System , Catalog ref. 4-10GPS. Sterile, One Time Use, Contents 4 sets 1- suture passer instrument, 1-guide rod, 10 mm, 250 mm long. Distributed by Aliez Medical Applications, Inc., Santa Ana, CA 92707. Synovis over labels the "Distributed by....", For Customer Service Contact: Synovis Surgical Innovations 2575 University Ave W., St. Paul, MN 55114-1024

FDA Recall
Terminated ·Synovis Surgical Inovation Div. of·Product code GDF·June 19, 2007

Allez Medical Applications, Inc. 4Closure Surgical Fascia Closure System , Catalog ref. 4-15GPS . Sterile, One Time Use, Contents 4 sets 1- suture passer instrument, 1-guide rod, 15 mm, 250 mm long. Distributed by Aliez Medical Applications, Inc., Santa Ana, CA 92707. Synovis over labels the "Distributed by....", For Customer Service Contact: Synovis Surgical Innovations 2575 University Ave W., St. Paul, MN 55114-1024

FDA Recall
Terminated ·Synovis Surgical Inovation Div. of·Product code GDF·June 19, 2007

Allez Medical Applications, Inc. 4Closure Surgical Fascia Closure System , Catalog ref. 4-23DGPS . Sterile, One Time Use, Contents 4 sets 1- suture passer instrument, 1-guide rod, 23 mm, 250 mm long, dilating. Distributed by Aliez Medical Applications, Inc., Santa Ana, CA 92707. Synovis over labels the "Distributed by....", For Customer Service Contact: Synovis Surgical Innovations 2575 University Ave W., St. Paul, MN 55114-1024

FDA Recall
Terminated ·Synovis Surgical Inovation Div. of·Product code GDF·June 19, 2007

Medtronic Mosaic Porcine Bioprostheses with Cinch, Heart Valve; Model 305; Catalog #s 305C21AA, 305C2701, 305C2301, 305C2501, and 305C2901; Sterile LC; Rx only; Medtronic Inc 710 Medtronic Parkway, Minneapolis, MN 55432-5604, Manufactured at: Santa Ana, Ca. Indicated for the replacement of malfunctioning native or aortic and mitral heart valves.

FDA Recall
Terminated ·Medtronic Inc·Product code DYE·January 26, 2009

Hancock II Bioprostheses with Cinch, Heart Valve, Model # T505 & T510; Catalog #s T505C2501, T505C2101, T505U25ID , T505C2301, T505C2301, T505C2501, T505C2101, T510C29ID, T510C25ID, and T510C27ID; Sterile LC; Rx only; Medtronic Inc 710 Medtronic Parkway, Minneapolis, MN 55432-5604, Manufactured at: Santa Ana, Ca. Indicated for the replacement of malfunctioning native or aortic and mitral heart valves.

FDA Recall
Terminated ·Medtronic Inc·Product code DYE·January 26, 2009

lnvatec SpA brand Diver C.E., Model/Catalog Numbers: DVR010014145, DVR011014145, Product is manufactured by lnvatec SpA, Roncadelle, Italy, and distributed by Invatec, Inc., Bethlehem, PA and by Medtronic Endovascular Therapies, Santa Rosa, CA The Diver C.E. product is an aspiration catheter indicated for the removal of fresh, soft emboli and thrombi from vessels in the arterial system.

FDA Recall
Terminated ·Invatec Llc·Product code DXE·March 4, 2009

Talent Captivia Stent Graft System - FreeFlow configurations only. Model numbers affected have the following designation: TFXXXXXXXXCP and TBXXXXXXXXCP. Medtronic Inc. Santa Rosa, CA 95403. The Talent Thoracic Stent Graft System is designed to treat thoracic aortic aneurysms using an endovascular approach. When placed within the target lesion, the stent graft provides an alternative conduit for blood flow within a patients vasculature by excluding the lesion from blood flow and pressure.

FDA Recall
Terminated ·Medtronic Vascular, Inc.·Product code MIH·February 21, 2012

Acecide-C High Level Disinfectant & Sterilant 875 mL. Packaging is 6 inner cartons in one master carton;1 inner carton consists of a set of two liquids (1 acid & 1 buffer) banded together.

FDA Recall
Terminated ·Best Sanitizers Inc·Product code MED·August 2, 2016

Medtronic brand AneuRx AAAdvantage Endovascular Stent Graft with the Xcelerant Delivery System; Model Numbers Affected: All AAAdvantage models including: AEXC202040, IEXC121255, ILXC1212115, ILXC151585, AEXC222240, IEXC131355, ILXC1212135, ILXC1616115, AEXC242440, IEXC141455, ILXC121285, ILXC1616135, AEXC262640, IEXC151555, ILXC1313115, ILXC161685, AEXC282840, IEXC161655, ILXC1313135, ILXC1620115, BFXC2012135, IEXC162085, ILXC131385, ILXC1620135, BFXC2012165, IEXC181855, ILXC1414115, ILXC1818115, BFXC2213135, IEXC182285, ILXC1414135, ILXC1818135, BFXC2213165, IEXC182485, ILXC141485, ILXC181885, BFXC2414135, IEXC202055, ILXC1515115, ILXC1822115, BFXC2414165, ILXC1515135, ILXC1822135, BFXC2615135, ILXC1824115, BFXC2615165, ILXC1824135, BFXC2816135, ILXC2020115, BFXC2816165, ILXC2020135, ILXC202085; Product is manufactured and distributed by Medtronic, Inc., Santa Rosa, CA 95403

FDA Recall
Terminated ·Medtronic CardioVascular·Product code MIH·December 10, 2007

Ovation Prime Abdominal Stent Graft System; Manufacturer: TriVascular, Inc. 3910 Brickway Blvd. Santa Rosa, CA 95403 The TriVascular Ovation Prime Abdominal Stent Graft System is an endovascular device delivered via a small diameter catheter to treat abdominal aortic aneurysms (AAAs). The stent graft is designed to reline the diseased vasculature, providing an endovascular blood conduit for isolating the aneurysm from the high pressure flow of blood, thereby reducing the risk of rupture. The stent graft is a modular configuration comprised of an aortic body section, iliac limbs, and iliac extensions as required.

FDA Recall
Terminated ·Trivascular, Inc·Product code MIH·February 27, 2014

SCREENERS Dip Drug Test, Catalog Number: SCD-7MB300 The SCREENERS Dip Drug Test is a one-step immunoassay for the qualitative detection of multiple drugs and drug metabolites in human urine at a given cutoff concentrations (refer to PN: 42131-SC). The SCREENERS Dip Drug Test is used to obtain a visual, qualitative result and is intended for professional use only. This assay provides only a preliminary result. Clinical consideration and professional judgment must be applied to any drug of abuse test result, particularly in evaluating a preliminary positive result. In order to obtain a confirmed analytical result, a more specific alternate chemical method is needed. Gas Chromatography/Mass Spectroscopy (GC/MS) is the preferred confirmation meth Drugs covered by the Screeners Dip Drug Test (SCD-7MB300): BAR, BZO, COC, MET, OPI300, PCP, THC.

FDA Recall
Terminated ·Ameditech Inc 10340 Camino Santa Fe·Product code DKZ·April 26, 2011

ProScreen PSCup-5M Waived, Catalog Number: PSCup-5M Waived Product Usage: The ProScreen Drugs of Abuse Test Cup is a one-step immunoassay for the qualitative detection of multiple drugs in human urine (refer to PN: 42141-PS-W). The ProScreen Drugs of Abuse Test Cup is used to obtain a visual, qualitative result and is intended for professional use only. The ProScreen Drugs of Abuse Cup is not for legal or medical diagnostic purposes. This device is not intended for workplace testing. For diagnostic and treatment purposes, consult with a healthcare or substance abuse professional. This assay provides only a preliminary result. Clinical consideration and professional judgment must be applied to any drug of abuse test result, particularly in evaluating a preliminary positive result. In order to obtain a confirmed analytical result, a more specific alternate chemical method is needed. Gas Chromatography/Mass Spectroscopy (GC/MS) is the preferred confirmation method.

FDA Recall
Terminated ·Ameditech Inc 10340 Camino Santa Fe·Product code DKZ·June 7, 2011