213 results
·
21ms
·
Sources: EU EUDAMED, US FDA
Filters
Status: Terminated
×
SKINFUSE Resuce Calming Complex Kit containing: SKINFUSE LIFT HG - Product Usage: The SKINFUSE Rescue Calming Complex is intend to be used to soothe and calm skin (cosmetic). The SKINFUSE LIFT HG is a hydrogel wound dressing to protect against abrasion and friction during the microneedling procedure.
FDA Recall
Terminated
·Bellus Medical·Product code QAI·January 18, 2019
Arsenal Spinal Fixation System, Set Screw, Part No. 47027 Product Usage: The Arsenal Spinal Fixation System is intended for posterior, non-cervical, spinal fixation as an adjunct to fusion for the treatment of degenerative disease, deformity, and trauma indications. The Arsenal System consists of a variety of shapes and sizes of rods, screws, hooks, connectors, and bridges that provide temporary internal fixation and stabilization during bone graft healing and/or fusion mass development. The screws, hooks, connectors, and bridges are manufactured from surgical grade titanium alloy (Ti-6AI-4V ELl). The rods are available in commercially pure titanium, titanium alloy, and cobalt chrome (CP Ti Grade 4, Ti-6AI-4V ELl, and Co-28Cr-6Mo).
FDA Enforcement
Class II
·Terminated·Alphatec Spine, Inc.·June 14, 2017
Arsenal Spinal Fixation System, Set Screw, Part No. 47027 Product Usage: The Arsenal Spinal Fixation System is intended for posterior, non-cervical, spinal fixation as an adjunct to fusion for the treatment of degenerative disease, deformity, and trauma indications. The Arsenal System consists of a variety of shapes and sizes of rods, screws, hooks, connectors, and bridges that provide temporary internal fixation and stabilization during bone graft healing and/or fusion mass development. The screws, hooks, connectors, and bridges are manufactured from surgical grade titanium alloy (Ti-6AI-4V ELl). The rods are available in commercially pure titanium, titanium alloy, and cobalt chrome (CP Ti Grade 4, Ti-6AI-4V ELl, and Co-28Cr-6Mo).
FDA Recall
Terminated
·Alphatec Spine, Inc. 5830 El Camino Real·Product code NKB·May 5, 2017
Depuy P.F.C. E Knee System TC3 Tibial Insert, 5, 12.5mm, 83mm M/L, 55mm A/P, UHMWPE/Ti-6AI-4V, sterile; Product Code/REF 96-0551.
FDA Recall
Terminated
·Depuy Orthopaedics, Inc.·Product code NJL·September 27, 2007
Depuy P.F.C. E Knee System TC3 Tibial Insert, 4, 20.0mm, 75mm M/L, 51mm A/P, UHMWPE/Ti-6AI-4V, sterile; Product Code/REF 96-0544.
FDA Recall
Terminated
·Depuy Orthopaedics, Inc.·Product code NJL·September 27, 2007
The Reliance 130 and 130L Cart Washer/Disinfector is a high capacity mechanical washer intended for use in the washing, low-level disinfecting, and drying of carts, utensils, beds and other miscellaneous reusable items used in the care of patients at healthcare facilities / Crated for shipping.
FDA Enforcement
Class II
·Terminated·Steris Corporation·August 8, 2012
Arsenal Spinal Fixation System, Set Screw, Part No. 47127 Product Usage: Usage: The Arsenal Spinal Fixation System is intended for posterior, non-cervical, spinal fixation as an adjunct to fusion for the treatment of degenerative disease, deformity, and trauma indications. The Arsenal System consists of a variety of shapes and sizes of rods, screws, hooks, connectors, and bridges that provide temporary internal fixation and stabilization during bone graft healing and/or fusion mass development. The screws, hooks, connectors, and bridges are manufactured from surgical grade titanium alloy (Ti-6AI-4V ELI). The rods are available in commercially pure titanium, titanium alloy, and cobalt chrome (CP Ti Grade 4, Ti-6Al-4V ELI, and Co-28Cr-6Mo).
FDA Enforcement
Class II
·Terminated·Alphatec Spine, Inc.·November 23, 2016
Depuy P.F.C. E Knee System TC3 Tibial Insert, 2.5, 15.0mm, 67 mm M/L, 45 mm A/P, UHMWPE/Ti-6AI-4V, sterile; Product Code/REF 96-0522.
FDA Recall
Terminated
·Depuy Orthopaedics, Inc.·Product code NJL·September 27, 2007
Depuy P.F.C. E Knee System TC3 Tibial Insert, 2.5, 12.5mm, 67 mm M/L, 45 mm A/P, UHMWPE/Ti-6AI-4V, sterile; Product Code/REF 96-0521.
FDA Recall
Terminated
·Depuy Orthopaedics, Inc.·Product code NJL·September 27, 2007
Depuy P.F.C. E Knee System TC3 Tibial Insert, 2.5, 30.0mm, 67mm M/L, 45 mm A/P, 30.0 mm, UHMWPE/Ti-6AI-4V, sterile; Product Code/REF 96-0527.
FDA Recall
Terminated
·Depuy Orthopaedics, Inc.·Product code NJL·September 27, 2007
Depuy P.F.C. E Knee System Depuy P.F.C. E Knee System TC3 Tibial Insert, 2.5, 17.5mm, 67 mm M/L, 45 mm A/P, UHMWPE/Ti-6AI-4V, sterile; Product Code/REF 96-0523.
FDA Recall
Terminated
·Depuy Orthopaedics, Inc.·Product code NJL·September 27, 2007
Arsenal Spinal Fixation System, Set Screw, Part No. 47127 Product Usage: Usage: The Arsenal Spinal Fixation System is intended for posterior, non-cervical, spinal fixation as an adjunct to fusion for the treatment of degenerative disease, deformity, and trauma indications. The Arsenal System consists of a variety of shapes and sizes of rods, screws, hooks, connectors, and bridges that provide temporary internal fixation and stabilization during bone graft healing and/or fusion mass development. The screws, hooks, connectors, and bridges are manufactured from surgical grade titanium alloy (Ti-6AI-4V ELI). The rods are available in commercially pure titanium, titanium alloy, and cobalt chrome (CP Ti Grade 4, Ti-6Al-4V ELI, and Co-28Cr-6Mo).
FDA Recall
Terminated
·Alphatec Spine, Inc. 5830 El Camino Real·Product code NKB·October 5, 2016
Trinica Anterior Lumbar Plate (ALP) system, part 07.01058.001. Non Sterile, Rx only. The Trinica Anterior Lumbar Plate System is a temporary supplemental fixation device consisting of a variety of shapes and sizes of plates and screws. The Trinica Anterior Lumbar Plate System is used as an implant for the correction and stabilization of the spine. This system provides temporary stabilization and augments the development of a solid spinal fusion. Additionally, this system provides the surgeon with the ability to supplement an interbody device with anterior plate fixation. The Trinica Anterior Lumbar Plate System components can be locked into a variety of configurations and each construct may be customized to individual cases. The plates are low profile and anatomically designed to provide optimal fit from either anterior or anterior-lateral approach. This system also features anti-migration locking caps to help secure the fixation screws. All Trinica Anterior Lumbar Plate System implant components are made from titanium alloy (Ti-6AI-4V). The Trinica Anterior Lumbar Plate System is indicated for use via the lateral or anterolateral surgical approach above the bifurcation of the great vessels or via the anterior surgical approach, below the bifurcation of the great vessels. This system is indicated in the treatment of lumbar or lumbosacral (L1-SI) spine instability as a result of fracture (including dislocation and subluxation), tumor, degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), pseudoarthrosis, spondylolisthesis, scoliosis, lordotic deformities of the spine, spinal stenosis, or a failed previous fusion.
FDA Enforcement
Class II
·Terminated·Zimmer, Inc.·November 27, 2013
Medtronic Temporary Pacemaker, Model 5348. Single Chamber External Pulse Generator (EPG) Temporary Pacemaker (AAI/VVI). Used in conjunction with a cardiac pacing lead system for temporary atrial or ventricular pacing in a clinical environment. The device is typically connected to temporary transvenous, epicardial or myocardial pacing leads, in a bipolar configuration, using a patient cable (Medtronic Model 5433A or 5433V) or a surgical cable (Medtronic Model 5832 or 5832S).
FDA Recall
Terminated
·Medtronic Inc. Cardiac Rhythm Disease Management·Product code LWP·April 29, 2014
Medtronic Temporary Pacemaker, Model 5348. Single Chamber External Pulse Generator (EPG) Temporary Pacemaker (AAI/VVI). Used in conjunction with a cardiac pacing lead system for temporary atrial or ventricular pacing in a clinical environment. The device is typically connected to temporary transvenous, epicardial or myocardial pacing leads, in a bipolar configuration, using a patient cable (Medtronic Model 5433A or 5433V) or a surgical cable (Medtronic Model 5832 or 5832S).
FDA Enforcement
Class II
·Terminated·Medtronic Inc. Cardiac Rhythm Disease Management·June 4, 2014
Insulia Diabetes Management Companion
FDA Recall
Terminated
·Voluntis 22 Quai Gallieni Suresnes France·Product code NDC·October 8, 2018
Halyard Closed Suction System for Adults, Multi-Access¿Port¿Closed¿Suction¿System¿for¿Adults. Used to aspirate liquids or semisolids from a patient's upper airway. a. HALYARD* MULTI-PORT, DSY, ENDO 10FR; b. HALYARD* MULTI-PORT, DSY, ENDO 12FR; c. HALYARD* MULTI-PORT, DSY, ENDO, MDI 12FR; d. HALYARD* MULTI-PORT, DSY, ENDO 14FR; e. HALYARD* MULTI-PORT, DSY, TRACH 14FR; f. HALYARD* MULTI-PORT, DSY, TRACH, WP 14FR; g. HALYARD* MULTI-PORT, DSY, ENDO, MDI 14FR; h. HALYARD* MULTI-PORT, DSY, ENDO, WP 14FR; i. HALYARD* MULTI-PORT, DSY, ENDO, WP 14FR; j. HALYARD* MULTI-PORT, DSY, ENDO, MDI 14FR; k. HALYARD* MULTI-PORT, DSY, ENDO, MDI 16FR;
FDA Enforcement
Class II
·Terminated·Halyard Health, Inc·April 25, 2018
Panta Arthrodesis Nail Support device, 510 (k) #K050882. One (1) unit of product is kitted within an instrumentation tray. The product is available in six (6) sizes. All nails are color-coded for easy size identification. Bony fixation is achieved using two (2) tibial screws, two (2) calcaneal screws and one (optional) talar screw. The nail, cross-locking screws and end cap are manufactured from a titanium alloy: TI-6AI-4V ELI ISO 5832-3, ASTM F136. The PANTA Arthrodesis Nail is intended for use in tibiotalocalcaneal arthrodesis and treatment of trauma to the hindfoot and distal tibia. The Panta Nail is intended for use in tibiotalocalcaneal arthrodesis and treatment of trauma to the hindfoot and distal tibia. Examples include: " Post-traumatic and degenerative arthritis involving both ankle and subtalar joints. " Rheumatoid arthritis. " Revision of failed ankle arthrodesis with subtalar involvement or with insufficient talar body. " Revision of failed total ankle arthroplasty with subtalar intrusion. " Talar deficiency conditions (requiring a tibiocalcaneal arthrodesis). " Avascular necrosis of the talus. " Neuroarthropathy or neuropathic ankle deformity. " Severe deformity as a result of talipes equinovarus, cerebral vascular accident, paralysis or other neuromuscular disease. " Severe pilon fractures with trauma to the subtalar joint.
FDA Recall
Terminated
·Integra LifeSciences Corp.·Product code HSB·May 19, 2011
Trinica Anterior Lumbar Plate (ALP) system, part 07.01058.001. Non Sterile, Rx only. The Trinica Anterior Lumbar Plate System is a temporary supplemental fixation device consisting of a variety of shapes and sizes of plates and screws. The Trinica Anterior Lumbar Plate System is used as an implant for the correction and stabilization of the spine. This system provides temporary stabilization and augments the development of a solid spinal fusion. Additionally, this system provides the surgeon with the ability to supplement an interbody device with anterior plate fixation. The Trinica Anterior Lumbar Plate System components can be locked into a variety of configurations and each construct may be customized to individual cases. The plates are low profile and anatomically designed to provide optimal fit from either anterior or anterior-lateral approach. This system also features anti-migration locking caps to help secure the fixation screws. All Trinica Anterior Lumbar Plate System implant components are made from titanium alloy (Ti-6AI-4V). The Trinica Anterior Lumbar Plate System is indicated for use via the lateral or anterolateral surgical approach above the bifurcation of the great vessels or via the anterior surgical approach, below the bifurcation of the great vessels. This system is indicated in the treatment of lumbar or lumbosacral (L1-SI) spine instability as a result of fracture (including dislocation and subluxation), tumor, degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), pseudoarthrosis, spondylolisthesis, scoliosis, lordotic deformities of the spine, spinal stenosis, or a failed previous fusion.
FDA Recall
Terminated
·Zimmer, Inc.·Product code KWQ·October 9, 2013
Halyard Closed Suction System for Adults, Turbo- cleaning¿Closed¿Suction¿System¿for¿Adults,¿Double¿Swivel¿Elbow (DSE). Used to aspirate liquids or semisolids from a patient's upper airway. a. HALYARD* TURBO-CLEANING 14FR DSE 21.3IN/54 CM (GREEN); b. HALYARD* TRACH CARE-72 DSE ENDO 14FR; c. HALYARD* TRACH CARE-72 WET PAK* 14FR; d. HALYARD* TRACH CARE-72 WET PAK* T-PIECE SWVL/FLEX ENDO 14FR; e. HALYARD* TURBO-CLEANING 14FR DSE 12IN/30.5 CM (GREEN); f. HALYARD* TRACH CARE-72 DSE TRACH 14FR; g. HALYARD* TRACH CARE-72 WET PAK* DSE TRACH 14FR; h. HALYARD* TRACH CARE-72 DSE ENDO 10FR; i. HALYARD* TURBO-CLEANING 10FR DSE 12IN/30.5CM (BLACK); j. HALYARD* TRACH CARE-72 DSE MDI BUILT IN ENDO 10FR; k. HALYARD* TRACH CARE-72 DSE MDI BUILT IN ENDO 12FR; l. HALYARD* TURBO-CLEANING 12FR DSE 12IN/30.5CM (WHITE); m. HALYARD* 72 DSE MDI BUILT IN ENDO 12FR; n. HALYARD* 72 DSE TRACH CARE 12FR; o. HALYARD* 14FR DSE 22.2IN/56CM (GREEN); p. HALYARD* TRACH CARE-72 DSE MDI BUILT IN ENDO 14FR; q. HALYARD* TURBO-CLEANING 14FR DSE 12IN/30.5CM (GREEN); r. HALYARD* TRACH CARE-72 DSE MDI BUILT IN TRACH 14FR; s. HALYARD* TC-72 WET PAK* DSE MDI ENDO 14FR; t. HALYARD* TC-72 WET PAK DSE MDI ENDO 14FR; u. HALYARD* TC-72 WET PAK DSE 14FR; v. HALYARD* TURBO-CLEANING 14FR DSE 21.3IN/54CM (GREEN); w. HALYARD* TURBO-CLEANING 12FR DSE 21.3IN/54 CM (WHITE); x. HALYARD* TRACH CARE-72 DSE ENDO 12FR; y. HALYARD* TURBO-CLEANING 12FR DSE 12IN/30.5CM (WHITE); z. HALYARD* TRACH CARE-72 DSE TRACH 12FR; aa. HALYARD* TRACH CARE-72 WET PAK* DSE TRACH 12FR; ab. HALYARD* TURBO-CLEANING 16FR DSE 21.3IN/54CM (ORANGE); ac. HALYARD* TRACH CARE-72 DSE 16FR 21.3IN/54CM; ad. HALYARD* TRACH CARE-72 DSE TRACH 16FR; ae. HALYARD* TRACH CARE-72 DSE ENDO 16FR; af. HALYARD* TRACH CARE-72 DSE MDI BUILT IN ENDO 16FR; ag. HALYARD* TRACH CARE-72 DSE MDI BUILT IN TRACH 16FR; ah. HALYARD* TRACH CARE-72 DSE MDI ENDO 16FR; ai. HALYARD* TRACH CARE-72 DSE 16FR; aj. HALYARD* TRACH CARE-72 WET PAK* DSE ENDO 12FR; ak. HALYARD* TURBO-CLEANING 14FR DSE 21.3IN/54CM (GREEN); al. HALYARD* TURBO-CLEANING 14FR DSE Endo;
FDA Enforcement
Class II
·Terminated·Halyard Health, Inc·April 25, 2018