The Flextome Cutting Balloon Device consists of a balloon with 3 or 4 atherotomes (microsurgical blades) mounted longitudinally on its outer surface. When the Flextome Cutting Balloon Device is inflated, the atherotomes score the plaque, creating initiation sites for crack propagation. This process, referred to as AtherotomyQ3J, allows dilatation of the target lesion with less pressure. The device is provided in 6 mm, 10 mm, and 15 mm lengths. The working length is the distance between the radiopaque marker bands. The proximal catheter shaft of the Flextome Cutting Balloon Device is a hypotube. This hypotube contains the inflation lumen for the balloon. The distal shaft is made of flexible material and contains two lumens. One lumen is for balloon inflation, and the second lumen is a guidewire lumen. The distal shaft is coated with a hydrophilic coating. The guidewire lumen is colored green for greater visibility. The guidewire exit port is 24 cm from the catheter tip. This port facilitates rapid exchanges. A needle with a luer port is included for flushing the wire lumen prior to the insertion of appropriate coronary guide wires. CLlPIT1M clips are provided to aid in handling of the catheter.

FDA Recall
Terminated ·Boston Scientific Corporation·Product code MCX·December 7, 2005

RotaWire Elite and wireClip Torquer, Guidewire and Guidewire Manipulation Device, Floppy. REF H802223301 (5-pack outer package), REF H802223300 (single unit). The Rotablator rotational atherectomy system consists of a diamond tipped burr capable of high speed rotation designed for plaque modification and debulking in vascular interventions. This system is designed to travel over a specialized 0.009 guidewire to guide the path of burr travel to deliver therapy where intended. The guidewires are intended for use with the Rotablator Rotational Atherectomy System.

FDA Recall
Terminated ·Boston Scientific Corporation·Product code MCX·October 9, 2015

Boston Scientific ROTAPRO, Rotational Atherectomy System Console, Model numbers H74939309010 (US) and H74939309030 (EU).

FDA Recall
Terminated ·Boston Scientific Corporation·Product code MCX·November 8, 2021

AngioJet Ultra 5000 A Console:Foot Switch Material number (U PN) 105650 Cardiovascular: The Console is a multiple-use device that controls the Thrombectomy Set. It drives the pump, regulates fluid inflow and outflow, provides the operator with Ultra System set-up prompts, total infused saline volume, and Ultra System malfunction warnings.

FDA Recall
Terminated ·Boston Scientific Corporation·Product code MCX·January 31, 2017

St. Jude Medical-CPS Direct SL- slittable CRT lead delivery tool. -Model Numbers 410110, 410111, 410112, 410113, 410114, 410115, 410116, 410120,410121. 410122, 410123, 410124, 410125 and 410126.

FDA Recall
Terminated ·St Jude Medical CRMD·Product code MCX·March 20, 2007

CSI, Diamondback 360 Coronary Orbital Atherectomy System, Part Number 70058-02, Model Number DBEC-125 Product Usage: The system is indicated to facilitate stent delivery in patients with coronary artery disease (CAD) who are acceptable candidates for PTCA or stenting due to de novo, severely calcified coronary artery lesions.

FDA Recall
Terminated ·Cardiovascular Systems, Inc.·Product code MCX·January 27, 2014

Diamondback 360 Coronary Orbital Atherectomy System, Model Number: DBEC-125. The system is indicated to facilitate stent delivery in patients with coronary artery disease (CAD) who are acceptable candidates for PTCA or stenting due to de novo, severely calcified coronary artery lesions.

FDA Recall
Terminated ·Cardiovascular Systems, Inc.·Product code MCX·March 4, 2015

CSI, Orbital Atherectomy System (OAS) Saline Infusion Pump, Rx only, Part Number: 7-10014, Model Number: SIP-3000. Product Usage: Usage: The pump is a component of the OAS that provides the pumping mechanism and power to the OAD. The pump does not have an indication independent from that of the systems. The Indications for Use for the peripheral and coronary systems are provided below: Peripheral: The DIAMONDBACK 360 and STEALTH Peripheral Orbital Atherectomy Systems are percutaneous orbital atherectomy systems indicated for use as therapy in patients with occlusive atherosclerotic disease in peripheral arteries and who are acceptable candidates for percutaneous transluminal atherectomy. The OAS supports removal of stenotic material from artificial arteriovenous dialysis fistulae (AV shunt). The systems are percutaneous orbital atherectomy systems indicated as therapy in patients with occluded hemodialysis grafts who are acceptable candidates for percutaneous transluminal angioplasty. Coronary: The DIAMONDBACK 360 Coronary Orbital Atherectomy System (OAS) is a percutaneous orbital atherectomy system indicated to facilitate stent delivery in patients with coronary artery disease (CAD) who are acceptable candidates for PTCA or stenting due to de novo, severely calcified coronary artery lesions

FDA Recall
Terminated ·Cardiovascular Systems Inc·Product code MCX·April 13, 2018

CSI, Orbital Atherectomy System (OAS) Saline Infusion Pump, Rx only, Part Number: 7-10014, Model Number: SIP-3000.

FDA Recall
Terminated ·Cardiovascular Systems Inc·Product code MCX·April 14, 2017

AngioJet Ultra Consoles-Thrombectomy System UPN: 105650-001D 105650-001H 105650-001R 105650-001Z 105650-002R 105650-004H 105650-004R 105650-007R 105650-009R 105650-024H 105650-024Z 105650-025 105650-025H 105650-025R 105650-026R Product Usage - The AngioJet allows for percutaneous removal of thrombus located in peripheral arteries and veins, saphenous vein bypass grafts, native coronary arteries, and native or synthetic AV access conduits. Thrombectomy is accomplished using high-pressure saline jets contained in the catheter shaft. The saline jets create a low-pressure effect to draw thrombus into the catheter, fragment the thrombus, and remove the thrombus from the treatment site. The system consists of a single use Thrombectomy Set (several models available) and a free standing mobile Console.

FDA Recall
Terminated ·Boston Scientific Corporation·Product code MCX·November 8, 2019

RotaWire Elite and wireClip Torquer, Guidewire and Guidewire Manipulation Device, Extra Support. REF H802233301 (5-pack outer package), REF H802233300 (single unit). The Rotablator rotational atherectomy system consists of a diamond tipped burr capable of high speed rotation designed for plaque modification and debulking in vascular interventions. This system is designed to travel over a specialized 0.009 guidewire to guide the path of burr travel to deliver therapy where intended. The guidewires are intended for use with the Rotablator Rotational Atherectomy System.

FDA Recall
Terminated ·Boston Scientific Corporation·Product code MCX·October 9, 2015

Angiojet Spiroflex, Catheter, 135 cm, 4F, Single use only, Sterilized with Ethylene Oxide, POSSIS MEDICAL, INC. 9055 Evergreen Boulevard NW Minneapolis, MN 55433-8003 USA- (Spiroflex Rheolytic Thrombectomy Catheter) is one component of the AngioJet Rheolytic Thrombectomy System (AngioJet System).

FDA Recall
Terminated ·Possis Medical, Inc·Product code MCX·May 1, 2007

(1) Capiox FX25 (West) Advance Oxygenator- with left port, 4-liter Reservoir, XC modified to Advance, Sterile Catalog Number: 3CX*FX25RWC (2) Capiox FX25 (East) Advance Oxygenator - FX25 with right port, 4-liter Reservoir, XC modified to Advance Catalog Number: 3CX*FX25REC CAPIOX FX25 Advance Oxygenator with Integrated Arterial Filter and Hardshell Reservoir-intended to be used to exchange gases between blood and a gaseous environment during cardiopulmonary bypass surgery.

FDA Enforcement
Class II ·Terminated·Terumo Cardiovascular Systems Corporation·December 23, 2020

Stat Profile Critical Care Xpress (CCX and CCX+), CCX Creatinine Membrane Kit for CCX analyzer Catalog # 35238 Intended for in vitro diagnostic use by health care professionals and for point-of-care usage in the quantitative determination of pH, PCO2, PO2, SO2%, Hematocrit (Hct), Ca++, total hemoglobin (tHb), Oxyhemoglobin (O2Hb), Carboxyhemoglobin (COHb), Methemoglobin (MetHb), reduced hemoglobin (HHb), Oxygen content (O2Ct) and Oxygen capacity (O2Cap) in heparinized whole blood; Na+, K+, CL-; Ca++, Mg++, Glucose heparinized whole blood, serum, or plasma.

FDA Recall
Terminated ·Nova Biomedical Corporation·Product code CGL·August 11, 2008

Terumo Capiox NX19 Oxygenator With Reservoir (East Orientation) P/N: 3CX*NX19RE

FDA Enforcement
Class II ·Terminated·Terumo Cardiovascular Systems Corporation·August 7, 2019

Terumo Capiox NX19 Oxygenator With Reservoir (West Orientation) P/N: 3CX*NX19RW

FDA Enforcement
Class II ·Terminated·Terumo Cardiovascular Systems Corporation·August 7, 2019

CCX Operating Software , Version 4.08

FDA Recall
Terminated ·Nova Biomedical Corporation·Product code CHL·January 27, 2006

Stat Profile Critical Care (CCX) Analyzer Catalog Number: 35942

FDA Recall
Terminated ·Nova Biomedical Corporation·Product code CHL·January 27, 2006

Stat Profile Critical Care Xpress CCX+ Analyzer Catalog Number: 37413

FDA Recall
Terminated ·Nova Biomedical Corporation·Product code CHL·March 30, 2004

Stat Profile Critical Care Xpress (CCX) Analyzer Catalog Number: 35942

FDA Recall
Terminated ·Nova Biomedical Corporation·Product code CHL·March 30, 2004