Endotec Prothesis Hip, Titanium Alloy, Sterilized. Acetabular Bearing, BP Hip System Component: 32x54 Acetabular Bearing, Catalog: 01-02-3254, 32x56 Acetabular Bearing, Catalog: 01-02-3256, Femoral Head Resurfacing Component, BP Hip System Component: 36.5mm Femoral Head Resurfacing Component:, Catalog: 01-03-0036, 38mm Femoral Head Resurfacing Component:, Catalog: 01-03-0038, 39.5mm Femoral Head Resurfacing Component:, Catalog: 01-03-0039, 41mm Femoral Head Resurfacing Component:, Catalog: 01-03-0041, 42.5mm Femoral Head Resurfacing Component:, Catalog: 01-03-0042, 44mm Femoral Head Resurfacing Component:, Catalog: 01-03-0044, 45.5mm Femoral Head Resurfacing Component:, Catalog: 01-03-0045, 47mm Femoral Head Resurfacing Component:, Catalog: 01-03-0047, 49mm Femoral Head Resurfacing Component:, Catalog: 01-03-0049, 51mm Femoral Head Resurfacing Component:, Catalog: 01-03-0051, 52mm Femoral Head Resurfacing Component:, Catalog: 01-03-0052. Femoral Stem BP Hip System Component: 10mm Femoral Stem Catalog: 01-04-0110, 11mm Femoral Stem Catalog: 01-04-0111, 12mm Femoral Stem Catalog: 01-04-0112.

FDA Recall
Terminated ·Endotec, Inc.·Product code JWH·June 5, 2009

Reusable laparoscopic instruments are packaged as non-sterile. Cleaning and sterilization of devices must occur prior to use. The instruments are intended to be used by qualified physicians to provide access, illumination and visualization of internal structures and for manipulating soft tissue (grasping, cutting, coagulating, dissecting and suturing) in a wide variety of diagnostic and therapeutic laparoscopic/ urologic closed and minimally invasive procedures. It is inserted via a trocar sleeve and is used to prepare, coagulate and cut tissue.

FDA Enforcement
Class II ·Terminated·Instrumed International, Inc.·October 8, 2014

Boston Scientific COGNIS CRT-D, Cardiac Resynchronization Therapy Defibrillator, models N118, N119. The following models are not available in the US: models N106, N107, P106, P107. Sterilized using ethylene oxide. Boston Scientific, 4100 Hamline Avenue North, St. Paul, MN 55112-5798 USA. Indicated for patients who are at risk for sudden cardiac death due to ventricular arrhythmias and may require pacing support.

FDA Enforcement
Class II ·Terminated·Boston Scientific CRM Corp·October 23, 2013