ICN TRANSDUCER KIT W/30ML FLUSH DEVICE FOR STANFORD UNIV. HOSP., Item No. 46065-64 The Transpac Disposable Straight Pressure Transducer (DSPT) is an extravascular pressure transducer that interfaces between a catheter and pressure monitor by converting changes in pressure into electrical currents that can be input into a compatible pressure monitor. The SafeSet Reservoir system is a blood sampling system assembled directly to the patient monitoring line (Transpac units). The SafeSet reservoir is used on patients where periodic blood sampling is required.
FDA Enforcement
Class II
·Terminated·ICU Medical, Inc.·November 23, 2016
ICN TRANSDUCER KIT W/30ML FLUSH DEVICE FOR STANFORD UNIV. HOSP., Item No. 46065-64 The Transpac Disposable Straight Pressure Transducer (DSPT) is an extravascular pressure transducer that interfaces between a catheter and pressure monitor by converting changes in pressure into electrical currents that can be input into a compatible pressure monitor. The SafeSet Reservoir system is a blood sampling system assembled directly to the patient monitoring line (Transpac units). The SafeSet reservoir is used on patients where periodic blood sampling is required.
FDA Recall
Terminated
·ICU Medical, Inc.·Product code DRS·September 27, 2016
EXTREMITY ARM PACK CONTENTS: (1) STOCKINETTE IMPERVIOUS 14" X 48" (1) GOBAN SELF-ADHERENT WRAP 6" X 5yds (3) BANDAGE ELASTIC 4" X 5yds (1) BANDAGE ESMARK 6" X 9 (1) UTILITY BOWL QUART 32oz (10) GAUZE SPONGE 4" X 4" 16PLY (1) TUBE SUCTION CONNECTX 12' (1) SKIN MARKER INK W/8 LABEL/TIME OUT/RULER (3) SCALPEL WITH HANDLE# 15 STAINLESS STEEL (1) TIME OUT BEACON NON WOVEN (1) LIGHT SHIELD (1) DRAPE INCISE ANTIMICROBIAL 23" X 17" (2) NEEDLE & BLADE COUNTER 10c MAG/CLEAR (1) U-DRAPE 60"X 70" WITH TAPE SPLIT 6" X 21" (1) NEEDLE SPINAL ANESTH 18G X 3% (3) GOWN X-LARGE IMPERVIOUS REINFORCED (1) MAYO STAND COVER REINFORCED (4) DR APE UTILITY WITH TAPE (6) TOWEL ABSORBENT 15" X 20" (3) DRAPE % ECONOMY 53" X 77" (1) YANKAUER OPEN TIP CLEAR W/0 CN (1) CAUTERY TIP POLISHER (1) SUTURE BAG FLORAL (1) GOWN SURG REINFORCED X-LARGE TOWEL & WRAP (1) MERLING SKIN PREP APPLICATOR 39ML (1) SHEET HAND 146" X 104" X 91" (1) TABLE COVER REINFORCED 50" X 90" Product Usage: EO sterilized surgical convenient packs packaged into polyester/polyethylene breather bag with Tyvek double vents.
FDA Enforcement
Class I
·Terminated·Customed, Inc·September 10, 2014
EXTREMITY ARM PACK CONTENTS: (1) STOCKINETTE IMPERVIOUS 14" X 48" (1) GOBAN SELF-ADHERENT WRAP 6" X 5yds (3) BANDAGE ELASTIC 4" X 5yds (1) BANDAGE ESMARK 6" X 9 (1) UTILITY BOWL QUART 32oz (10) GAUZE SPONGE 4" X 4" 16PLY (1) TUBE SUCTION CONNECTX 12' (1) SKIN MARKER INK W/8 LABEL/TIME OUT/RULER (3) SCALPEL WITH HANDLE# 15 STAINLESS STEEL (1) TIME OUT BEACON NON WOVEN (1) LIGHT SHIELD (1) DRAPE INCISE ANTIMICROBIAL 23" X 17" (2) NEEDLE & BLADE COUNTER 10c MAG/CLEAR (1) U-DRAPE 60"X 70" WITH TAPE SPLIT 6" X 21" (1) NEEDLE SPINAL ANESTH 18G X 3% (3) GOWN X-LARGE IMPERVIOUS REINFORCED (1) MAYO STAND COVER REINFORCED (4) DR APE UTILITY WITH TAPE (6) TOWEL ABSORBENT 15" X 20" (3) DRAPE % ECONOMY 53" X 77" (1) YANKAUER OPEN TIP CLEAR W/0 CN (1) CAUTERY TIP POLISHER (1) SUTURE BAG FLORAL (1) GOWN SURG REINFORCED X-LARGE TOWEL & WRAP (1) MERLING SKIN PREP APPLICATOR 39ML (1) SHEET HAND 146" X 104" X 91" (1) TABLE COVER REINFORCED 50" X 90" Product Usage: EO sterilized surgical convenient packs packaged into polyester/polyethylene breather bag with Tyvek double vents.
FDA Recall
Terminated
·Customed, Inc Calle Igualdad Final # 7·Product code LRO·May 20, 2014
IDS-iSYS Ostase BAP (Bone Alkaline Phosphatase) Control Set, Catalog Number IS-2830. Packaged in cardboard Box containing plastic bottles. The IDS-iSYS Ostase BAP (IDS-iSYS BAP) Control Set is used for quality control of the IDS-iSYS Ostase BAP (Bone Alkaline Phosphatase) Assay on the IDS-iSYS Multi-Discipline Automated Analyser.
FDA Recall
Terminated
·Immunodiagnostics Systems Ltd 10 Didcot Way Bolden Business Park Boldon Tyne & Wear United Kingdom·Product code CIN·August 10, 2012
Access Ostase Calibrators, Part Number: 37305, Subsequent Product Code: JIS. The Access Ostase Calibrators are intended to calibrate the Access Ostase assay for the quantitative determination of bone alkaline phosphatase (BAP) levels in human serum and plasma using the Access Immunoassay Systems.
FDA Recall
Terminated
·Beckman Coulter Inc.·Product code CIN·November 10, 2011
C-Reactive Protein Kit for use on the SPAplus, REF NK044.S.A, Rx only, UDI (01)05051700018456,
FDA Recall
Terminated
·The Binding Site Group, Ltd.·Product code DCN·April 25, 2019
Tina-quant C-Reactive Protein Gen.3, Catalog number 05172373190 - Product Usage: the in vitro quantitative determination of CRP in human serum and plasma on Roche automated clinical chemistry analyzers.
FDA Recall
Terminated
·Roche Diagnostics Operations, Inc.·Product code DCN·November 6, 2020
IDS-iSYS Ostase BAP (Bone Alkaline Phosphatase), Catalog Number IS-2800. Packaged in cardboard Box containing plastic bottles. The IDS-iSYS Ostase BAP Assay (IDS-iSYS BAP) is intended for the quantitative determination of bone-specific alkaline phosphatase (BAP), an indicator of osteoblastic activity, in human serum or plasma on the IDS-iSYS Multi- Discipline Automated Analyser (Analyser). Results are to be used in conjunction with other clinical and laboratory data to aid the clinician in the management of post menopausal osteoporosis and Pagets disease.
FDA Recall
Terminated
·Immunodiagnostics Systems Ltd 10 Didcot Way Bolden Business Park Boldon Tyne & Wear United Kingdom·Product code CIN·August 10, 2012
MicroVue BAP EIA, Model 8012, provides a quantitative measure of bone-specific alkaline phosphatase (BAP) activity in serum.
FDA Recall
Terminated
·Diagnostic Hybrids, Inc.·Product code CIN·July 14, 2016
IDS-iSYS Intact PINP, Catalog Number IS-4000. Packaged in cardboard Box containing plastic bottles. The IDS-iSYS Intact amino-terminal propeptide of type I procollagen (Intact PINP) assay is intended for the quantitative determination of intact PINP in human serum or plasma on the IDS-iSYS Multi-Discipline Automated Analyser.
FDA Recall
Terminated
·Immunodiagnostics Systems Ltd 10 Didcot Way Bolden Business Park Boldon Tyne & Wear United Kingdom·Product code CIN·August 10, 2012
Amvex Integrated Flowmeter; a nonback-pressure compensated Bourdon gauge flowmeter; Amvex Corporation, 25B East Pearce St, Richmond Hill, Ontario L4B 2M9, Canada; Model No. FI. The Integrated Flowmeter has two parts, the Outlet port and the Flowmeter port. The Outlet port is intended to be used as a standard wall Outlet, delivering a high flow of gas to secondary equipment. The Flowmeter port is intended to deliver a fixed flow of gas to patient or equipment.
FDA Recall
Terminated
·Amvex Corporation·Product code CCN·May 29, 2009
Optilite C-Reactive Protein Kit - Product Usage: The Optilite C-Reactive Protein Reagent is intended for the quantitative in vitro determination of C-reactive protein (CRP) concentration in serum using the Binding Site Optilite analyser. Measurement of C-Reactive Protein aids in evaluation of the amount of injury to body tissues and for evaluation of infection, tissue injury, and inflammatory disorders. This test should be used in conjunction with other laboratory and clinical findings. The Optilite C-Reactive Protein Calibrator is intended for the calibration of the Optilite C-Reactive Protein Reagent on the Optilite analyser. The Optilite C-Reactive Protein Controls are intended for use in quality control by monitoring accuracy and precision for the Optilite C-Reactive Protein Reagent.
FDA Recall
Terminated
·The Binding Site Group, Ltd.·Product code DCN·February 19, 2019
ACCESS Ostase Part Number: 37300 Used for the quantitative measurement of bone alkaline phosphatase (BAP).
FDA Recall
Terminated
·Beckman Coulter Inc.·Product code CIN·June 22, 2011
Access Ostase Reagent, Part Number: 37300, subsequent product code: JIS. The Access Ostase Assay is used for the quantitative measurement of bone alkaline phosphatase (BAP), an indicator of osteoblastic activity, in human serum and plasma. This device is intended to be used as an aid in the management of postmenopausal osteoporosis and Pagets disease.
FDA Recall
Terminated
·Beckman Coulter Inc.·Product code CIN·November 10, 2011
Dimension Flex Reagent Cartridge C-Reactive Protein Extended Range (RCRP). In vitro diagnostic test intended for the quantitative determination of CRP in human serum and plasma (lithium heparin). Measurement of C-Reactive Protein is useful for the detection and evaluation of infection, tissue injury, inflammatory disorders and associated diseases.
FDA Recall
Terminated
·Siemens Healthcare Diagnostics, Inc.·Product code DCN·April 15, 2008
7" (18 cm) Appx 0.26 ml, Smallbore Ext Set w/MicroClave¿ Clear, NThe ICU Needleless Connector is a single use, sterile, non-pyrogenic device intended for use as an accessory to intravascular administration set for the administration of fluids to a patient through a cannula placed in the vein or artery.anoClave", Clamp, Luer Lock, Part No. A1000, Item No. K7089-001
FDA Enforcement
Class II
·Terminated·ICU Medical, Inc.·January 15, 2014
11" Smallbore Bifuse Ext Set w/1.2 Micron Filter, NanoClave", 3 Clamps, Rotating Luer, Part No. A1000, Item No. K7105-001 The ICU Needleless Connector is a single use, sterile, non-pyrogenic device intended for use as an accessory to intravascular administration set for the administration of fluids to a patient through a cannula placed in the vein or artery.
FDA Enforcement
Class II
·Terminated·ICU Medical, Inc.·January 15, 2014
7" (18 cm) Appx 0.24 ml, Smallbore Ext Set w/NanoClave", Clamp, Luer Lock, Part No. A1000, Item No. K7095-001 The ICU Needleless Connector is a single use, sterile, non-pyrogenic device intended for use as an accessory to intravascular administration set for the administration of fluids to a patient through a cannula placed in the vein or artery.
FDA Enforcement
Class II
·Terminated·ICU Medical, Inc.·January 15, 2014
183 cm (72") Smallbore Quadfuse Ext Set w/4 NanoClave¿ (Yellow, Green Rings), 4 Anti-Syphon Valves, 0.2 Micron Positive Filter, BCVClave ¿, NanoClave¿ T-Connector, Rotating Luer, Part No. A1000, Item No. 011-A1094 The ICU Needleless Connector is a single use, sterile, non-pyrogenic device intended for use as an accessory to intravascular administration set for the administration of fluids to a patient through a cannula placed in the vein or artery.
FDA Enforcement
Class II
·Terminated·ICU Medical, Inc.·January 15, 2014