Monoswift PGCL [poly (glycolide-co-caprolactone)] Absorbable Surgical Suture; USP size 3/0 PGCL; part number L936. Product is labeled sterile. The product is sealed inside an inner foil pouch with an outside Tyvek pouch. It is an undyed, monofilament synthetic absorbable suture with needle, size 3/0 (2.0 metric), PS-1 Needle

FDA Recall
Terminated ·C P Medical Inc.·Product code NEW·April 23, 2014

Monoswift PGCL [poly(glycolide-co-caprolactone)] Absorbable Surgical Suture; USP size 3/0. Product is labeled sterile. The product is sealed inside an inner foil pouch with an outside Tyvek pouch. It is an undyed, monofilament synthetic absorbable suture with needle size 3/0.

FDA Recall
Terminated ·C P Medical, Inc.·Product code NEW·September 22, 2014

Monoswift¿ PGCL [poly (glycolide-co-caprolactone)] Absorbable Surgical Suture; USP size 3/0 PGCL; part number L936. Product is labeled sterile. The product is sealed inside an inner foil pouch with an outside Tyvek¿ pouch. It is an undyed, monofilament synthetic absorbable suture with needle, size 3/0 (2.0 metric), PS-1 Needle

FDA Enforcement
Class II ·Terminated·C P Medical Inc.·June 11, 2014

Monoswift PGCL [poly(glycolide-co-caprolactone)] Absorbable Surgical Suture; USP size 3/0. Product is labeled sterile. The product is sealed inside an inner foil pouch with an outside Tyvek pouch. It is an undyed, monofilament synthetic absorbable suture with needle size 3/0.

FDA Enforcement
Class II ·Terminated·C P Medical, Inc.·November 5, 2014

Product is a synthetic absorbable suture with needle and labeled as sterile. The product is sealed inside an inner foil pouch with an outside Tyvek pouch. The outer sterile barrier seal is intact. The product is boxed and shrink wrapped for protection against contamination. The product is a Violet, monofilament synthetic absorbable suture with needle, size 3/0 (2.0 Metric), NFS-2 Needle (Product code 398A-Polyglycolic Acid) or size 2/0 (3.0 Metric) NFS-1 Needle. (Product code 453A-Polyglycolic Acid). Product is labeled in part: "***NFS-1***CUTTING***Coated POLYGLYCOLIC ACID Violet (PGA) Braided Absorbable Suture STERILE***Manufacturer CP Medical***". Intended for use in general soft tissue approximation and/or ligation including use in pediatric cardiovascular tissue where growth is expected to occur, and ophthalmic surgery. The suture is not recommended for adult cardiac tissue, microsurgery or neural tissue. The absorbable sutures are useful where extended wound support is desirable.

FDA Recall
Terminated ·C P Medical Inc.·Product code GAM·January 2, 2009

Varian brand Varian ARIA Oncology Information System, Import Export application, v 11.0; Reference/FSCA Identifier: CP-08847; Model Number: HIT; Product is manufactured and distributed by Varian Medical Systems Inc., Palo Alto, CA The ARIA Radiation Oncology product is a treatment plan and image management application. It enables the authorized user to enter, access, modify, store and archive treatment plan and image data from diagnostic studies, treatment planning, simulation, plan verification and treatment. ARIA Radiation Oncology also stores the treatment histories including dose delivered to defined sites and provides tools to verify performed treatments. ARIA also includes optional tools to manage the oncology department's clinical and business information.

FDA Enforcement
Class II ·Terminated·Varian Medical Systems, Inc. Oncology Systems·August 15, 2012

Product is a synthetic absorbable suture with needle and labeled as sterile. The product is sealed inside an inner foil pouch with an outside Tyvek pouch. The outer sterile barrier seal is intact. The product is boxed and shrink wrapped for protection against contamination. The product is a Violet, monofilament synthetic absorbable suture with needle, size 4/0 (1.5 Metric), NFS-2 Needle (Product code M397-Polydioxanone) or size 3/0 (2.0 Metric) (Product code M398 {Butler code 029254}). Product is labeled in part: "***POLYDIOANONE Violet (PDO) Monofilament Absorbable Suture***". Intended for use in general soft tissue approximation and/or ligation including use in pediatric cardiovascular tissue where growth is expected to occur, and ophthalmic surgery. The suture is not recommended for adult cardiac tissue, microsurgery or neural tissue. The absorbable sutures are useful where extended wound support is desirable.

FDA Recall
Terminated ·C P Medical Inc.·Product code NEW·January 2, 2009

Varian brand ARIA Radiation Oncology, ARIA Oncology Information System Radiation Oncology, Import Export Application, Model Number: HIT, Affected Versions: ARIA version 11.0 below 11.0.55, Build 11.0.28 and 11.0.34, Reference/FSCA Identifier: CP-09798; Product is manufactured and distributed by Varian Medical Systems Inc., Palo Alto, CA

FDA Enforcement
Class II ·Terminated·Varian Medical Systems, Inc. Oncology Systems·December 26, 2012

Product is an EO Sterile, Polydioxanone Violet monofilament synthetic absorbable surgical suture with needle, size 3/0 (2.0 Metric), NFS-2, 19 mm Needle. Product is sealed inside an inner foil pouch with an outside tyvek pouch. The outer tyvek pouch has the defective seal. No suture is exposed or visible through the foil wrap which must be torn to have access to the suture and needle. Product is boxed (12 to a box) and shrink wrapped. Product is labeled STERILE. Box Label includes: '3/0 (2.0 metric) MONO-DOX Violet Monofilament Polydioxanone Suture USP M398A CP-B-M398A-04 Rx Only NFS-2 19 mm 3/8 CUTTING Manufactured by: CP Medical Portland, OR USA 30' (75 cm) One Dozen Sterile Synthetic Absorbable Suture '. Packet Label includes: '3/0 (2.0 metric) 398 NFS-2 19mm 3/8 CUTTING 30' (75cm) POLYDIOXANONE Violet (PDO) Monofilament Synthetic Absorbable Suture STERILE EO Manufacturer: CP Medical Portland, OR USA' . Product is also distributed under three private labels, Webster Veterinary, Butler, and Phoenix Pharmaceutical, Inc. Webster Veterinary Box Label includes: '3/0 (2.0 metric) WEBMAX Violet Monofilament Polydioxanone Suture Distributed by: WEBSTER VETERINARY 07-836-4288(M398A) 26-BM398A-01 Vet Use Only CUTTING NFS-2 30' (75 cm) 3/8 19mm'. Webster Veterinary Packet Label includes: '3/0 (2.0 metric) 07-836-4288(M398A) WEBMAX Violet Monofilament Polydioxanone Absorbable Sterile Suture 30' (75cm) Vet Use Only Distributed by: Webster Veterinary Supply, Inc. CUTTING NFS-2 3/8 19mm 26-SM398A-01'. Butler Box label includes: 'Butler 3/0 (2.0 metric) MONOSORB Violet Monofilament Polydioxanone Suture 029254 Vet Use Only NFS-2 CUTTING 30' (75 cm) 3/8 19mm 01-BM398A-02 SUTUREVET'. Butler Packet Label includes: '3/0 (2.0 metric) NFS-2 19mm 3/8 CUTTING 30' (75cm) 029254 MONOSORB Violet Monofilament Prolydioxanone Synthetic Absorbable Suture STERILE EO Distributed Exclusively by: Butler Animal Health Supply'. Phoenix Pharmaceutical Box label includes: '3/0 (2.0 metric) 0398 Poly-Dox Sutures VIOLET MONOFILAMENT (Polydioxanone) Suture Sterile Synthetic Absorbable Suture 30' (75cm) Vet Use Only Cutting PFS-2 3/8 19mm Distributed By: PHOENIX PHARMACEUTICAL, INC.'. Phoenix Pharmaceutical Packet label includes: '3/0 (2.0 metric) 0398 Poly-Dox Sutures VIOLET MONOFILAMENT (Polydioxanone) Suture 30' (75cm) Sterile, Synthetic Absorbable Suture Veterinary Use Only Cutting PFS-2 3/8 19mm Distributed By: PHOENIX PHARMACEUTICAL, INC.'.

FDA Recall
Terminated ·C P Medical·Product code GAM·April 3, 2007

Varian brand ARIA Radiation Oncology, ARIA Oncology Information System Radiation Oncology, Import Export Application, Model Number: HIT, Affected Versions: ARIA version 11.0 below 11.0.55, Build 11.0.28 and 11.0.34, Reference/FSCA Identifier: CP-09798; Product is manufactured and distributed by Varian Medical Systems Inc., Palo Alto, CA

FDA Recall
Terminated ·Varian Medical Systems, Inc. Oncology Systems·Product code IYE·November 5, 2012

ILLICO Straight CP TI Rod, -5.5MM x 110M; REF#73601-110; Qty 1; LBL-005; REV.B; RX ONLY; Alphatec Spine, Inc. The ILLICO MIS Posterior Spinal Fixation System is intended to facilitate the surgical correction of non-cervical spinal deformities by providing temporary internal fixation and stabilization during bone graft healing and/or fusion mass development.

FDA Recall
Terminated ·Alphatec Spine, Inc.·Product code KWP·July 6, 2011

Monomid Non-Absorbable Suture are blue, monofilament synthetic absorbable suture, with different sizes and different needle sizes. The products are labeled in parts. These sutures are intended for use in general soft tissue approximation and/or ligation including use in cardiovascular, ophthalmic, and neurological surgery.

FDA Recall
Terminated ·C P Medical Inc.·Product code GAR·June 29, 2011

Optical Guidance Platform, version 2.6 and 2.6.1; Reference/FSCA Identifier: CP-03899; Product is manufactured and distributed by Varian Medical Systems Inc., Palo Alto, CA Optical Guidance Platform is for use with a charged particle accelerator to perform precise positioning of treatment target for stereotactic radiosurgery or radiotherapy treatments on cranial or extracranial lesions.

FDA Recall
Terminated ·Varian Medical Systems, Inc. Oncology Systems·Product code IYE·March 3, 2011

Optical Guidance Platform, version 2.6 and 2.6.1; Reference/FSCA Identifier: CP-03976; Model Number: HZ1; Product is manufactured and distributed by Varian Medical Systems Inc., Palo Alto, CA Optical Guidance Platform is for use with a charged particle accelerator to perform precise positioning of treatment target for stereotactic radiosurgery or radiotherapy treatments on cranial or extracranial lesions.

FDA Recall
Terminated ·Varian Medical Systems, Inc. Oncology Systems·Product code IYE·March 3, 2011

Product is an EO Sterile, Blue Polypropylene monofilament synthetic nonabsorbable surgical suture with needle, size 3/0 (2.0 Metric), NFS-2, 19 mm Needle. Product is wrapped in a five-fold card with inserted flap ends (overwrap). A label is placed on the overwrap and the packet is then inserted into a tyvek/mylar pouch. One end of the overwrap card is printed with 'Open'. This end is positioned in the pouch so it is closest to the peel-open end. No suture is exposed or visible through the overwrap which must be torn to have access to the suture and needle. Product is boxed (12 to a box) and shrink wrapped. Product is labeled STERILE. Box Label includes: '3/0 (2.0 metric) POLYPRO Blue Monofilament Polypropylene Nonabsorbable Suture 8665P Rx Only NFS-2 19 mm 3/8 CUTTING 18' (45 cm) One Dozen Sterile Manufactured by: CP Medical Portland, OR USA' . Side of box has an adhesive sticker label which includes: 'Vet Use Only'. Packet Label includes: '3/0 (2.0 metric) 8665 NFS-2 19mm 3/8 TAPER POLYPROPYLENE Blue Polypropylene Monofilament Synthetic Nonabsorbable Suture 18' (45 cm) STERILE EO Manufacturer: CP Medical Portland, OR USA' . Product is also distributed under two private labels, Webster Veterinary and Butler. Webster Veterinary Box Label includes: '3/0 (2.0 metric) WEBPRO Blue Monofilament Polypropylene Nonabsorbable Suture Distributed by: WEBSTER VETERINARY One Dozen Sterile 07-836-4643(8665P) 26-B8665P-02 Vet Use Only CUTTING NFS-2 18' (45 cm) 3/8 19mm'. Webster Veterinary Packet Label includes: '3/0 (2.0 metric) WEBPRO Blue Monofilament Polypropylene Nonabsorbable Sterile Suture Vet Use Only Distributed by: Webster Veterinary Supply, Inc. 07-836-4643(8665P) 26-B8665P-02 NFS-2 18' (45 cm) CUTTING 3/8 19mm'. Butler Box label includes: 'Butler 3/0 (2.0 metric) PROMEND Blue Monofilament Polypropelene 032002 Vet Use Only NFS-2 CUTTING 18' (45 cm) 3/8 19mm 01-B8665P-01 SUTUREVET'. Butler Packet Label includes: '3/0 (2.0 metric) NFS-2 19mm 3/8 CUTTING 18' (45cm) 032002 PROMEND Blue Propylene Monofilament Synthetic Nonabsorbable Suture STERILE EO Distributed Exclusively by: Butler Animal Health Supply'.

FDA Recall
Terminated ·C P Medical·Product code GAW·April 3, 2007

Eclipse Treatment Planning System, 4D Structure Merge Tool Option in Eclipse Release 8.5 -10 (Client Build 8.2.2x through 10.0.34) with 4D Planning; Model Number: H48; Reference/FSCA Identifier: CP-04931; Product is manufactured and distributed by Varian Medical Systems Inc., Palo Alto, CA The Eclipse Treatment Planning System (Eclipse TPS) is used to plan radiotherapy treatments for patients with malignant or benign diseases.

FDA Recall
Terminated ·Varian Medical Systems, Inc. Oncology Systems·Product code MUJ·July 7, 2011

Varian brand Clinac, Trilogy, Novalis Tx, Unique, linear accelerators; Model Number: H14, H18, H29, Reference/FSCA Identifier: CP-08881; Product is manufactured and distributed by Varian Medical Systems Inc., Palo Alto, CA. 1) The Varian Low Energy Linear Accelerator is indicated for precision radiotherapy for lesions, tumors and conditions anywhere in the body when radiation treatment i is indicated. (2) The Varian High Energy Linear Accelerator is indicated for stereotactic radiosurgery and precision radiotherapy for lesions, tumors and conditions anywhere in the body when radiation treatment is indicated.

FDA Enforcement
Class II ·Terminated·Varian Medical Systems, Inc. Oncology Systems·September 26, 2012

Varian brand Eclipse Treatment Planning System, Model Number: H48; Eclipse 8.9 and 10.0 Reference/FSCA Identifier: CP-08922; Product is manufactured and distributed by Varian Medical Systems Inc., Palo Alto, CA The Eclipse Treatment Planning System (Eclipse TPS) is used to plan radiotherapy treatments for patients with malignant or benign diseases. Eclipse TPS is used to plan external beam irradiation with photon, electron and proton beams, as well as for internal irradiation (brachytherapy) treatments. In addition, the Eclipse Proton Eye algorithim is specifically indicated for planning proton treatment of neoplasms of the eyes.

FDA Enforcement
Class II ·Terminated·Varian Medical Systems, Inc. Oncology Systems·October 3, 2012

Varian brand 52-leaf Millennium MLC multileaf collimator; Reference/FSCA Identifier: CP-04792; All models, including H52, H54, H56, HHM; Product is manufactured and distributed by Varian Medical Systems Inc., Palo Alto, CA. The Multileaf Collimator is intended to assist the Radiation Oncologist in the delivery of radiation to well defined target volumes while sparing surrounding normal tissue and critical organs from excess radiation.

FDA Recall
Terminated ·Varian Medical Systems, Inc. Oncology Systems·Product code IYE·January 16, 2012

Varian brand Varian 52-leaf Standard MLC multileaf collimator; Reference/FSCA Identifier: CP-04792; Model Number(s): All models, including H52, H54, H56, HHM; Product is manufactured and distributed by Varian Medical Systems Inc., Palo Alto, CA. The Multileaf Collimator is intended to assist the Radiation Oncologist in the delivery of radiation to well defined target volumes while sparing surrounding normal tissue and critical organs from excess radiation.

FDA Recall
Terminated ·Varian Medical Systems, Inc. Oncology Systems·Product code IYE·January 16, 2012