28 results · 12ms · Sources: EU EUDAMED, US FDA

Get notified when this changes

We'll email you when new records match this search — new devices, new clearances, certificate changes, or withdrawals.

AirLife Isothermal Breathing Circuit, Infant Respiratory Circuit, Heated; an Rx device for single patient use; CareFusion, 22745 Savi Ranch Parkway, Yorba Linda, CA 92887 USA, Made in Mexico Respiratory breathing circuits are used with a ventilator when mechanical ventilation is administered to a patient.

FDA Recall
Terminated ·Product code BZE·May 29, 2012

CareFusion AirLife Heated Infant Breathing Circuit Product Usage: Respiratory breathing circuits are used with a ventilator when mechanical ventilation is administered to a patient.

FDA Recall
Terminated ·Carefusion 2200 Inc 75 N Fairway Dr Vernon Hills IL 60061-1845·Product code BZE·July 31, 2014

Teleflex HUDSON RDI NEONATAL ConchaSmart Breathing Circuit with Dual Heated Limb and ConchaSmart Column: a) REF 870-07KIT b) REF 870-09KIT Product Usage: The Neonatal ConchaSmart breathing circuits are intended to deliver humidified breathing gases for administration to an infant/neonate patient. These gases may be delivered by nasal prongs using the CareFusion Infant Flow system and the single limb circuit, or through bypassing upper airways, for example through the use of an endotracheal tube with the dual limb configuration.

FDA Recall
Terminated ·Teleflex Medical·Product code BZE·May 10, 2019

AirLife Isothermal Breathing Circuit, Infant Respiratory Circuit, Non-Heated; an Rx device for single patient use; CareFusion, 22745 Savi Ranch Parkway, Yorba Linda, CA 92887 USA, Made in Mexico Respiratory breathing circuits are used with a ventilator when mechanical ventilation is administered to a patient.

FDA Recall
Terminated ·Product code BZE·May 29, 2012

AirLife Isothermal Breathing Circuit Accessory - Infant Patient Y Connector; an Rx device for single patient use; 30 connectors per box; CareFusion, 22745 Savi Ranch Parkway, Yorba Linda, CA 92887 USA, Made in Mexico Respiratory breathing circuits are used with a ventilator when mechanical ventilation is administered to a patient.

FDA Recall
Terminated ·Product code BZE·May 29, 2012

BD BBL BBE // CDC Anaerobe Laked Sheep Blood Agar with KV, packaged in cartons of 100 plates, Catalog # 297260, and labeled in part ***Becton, Dickinson and Company 7 Loveton Circle Sparks, MD 21152 USA 800-638-8663 www.bd.com/ds*** Bacteroides Bile Esculin Agar (BBE) is recommended as a primary isolation medium for the selection and presumptive identification of the B. fragilis group.

FDA Enforcement
Class II ·Terminated·Becton Dickinson & Co.·July 31, 2013

BD BBL BBE // CDC Anaerobe Laked Sheep Blood Agar with KV, packaged in cartons of 100 plates, Catalog # 297260, and labeled in part ***Becton, Dickinson and Company 7 Loveton Circle Sparks, MD 21152 USA 800-638-8663 www.bd.com/ds*** Bacteroides Bile Esculin Agar (BBE) is recommended as a primary isolation medium for the selection and presumptive identification of the B. fragilis group.

FDA Recall
Terminated ·Becton Dickinson & Co. BD Diagnostic Systems·Product code JSI·June 6, 2013

G7 DUAL MOBILITY LINER 44MM F Product Usage: Intended for use in hip arthroplasty cases which involves the removal of the damaged joint and tissues to be replaced with artificial prosthesis. The result of the procedure is to relieve pain and restore a sense of normal function and mobility to the damaged joint.

FDA Enforcement
Class II ·Terminated·Zimmer Biomet, Inc.·February 21, 2018

Primus (THE BTE WS30), model PrimusRS (PRRS) and Primus+ (PR30) a measuring exercise equipment device designed to provide active and passive torque resistance to patient motion during rehabilitation therapy. The Primus that includes the optional Chop / Lift Bar.

FDA Recall
Terminated ·BTE Technologies, Inc.·Product code ISD·April 9, 2015

Primus (THE BTE WS30), model PrimusRS (PRRS) and Primus+ (PR30) a measuring exercise equipment device designed to provide active and passive torque resistance to patient motion during rehabilitation therapy. The Primus that includes the optional Chop / Lift Bar.

FDA Enforcement
Class II ·Terminated·BTE Technologies, Inc.·July 15, 2015

NanoKnife Irreversible Electroporation System. System consists of multiple components: Generator, footswitch, disposable electrode. System is manufactured by AngioDynamics, Inc. --- Catalog #20300101 Intended use: the generator system with six outputs is indicated for surgical ablation of soft tissue.

FDA Recall
Terminated ·Angiodynamics Worldwide Headquarters·Product code OAB·January 20, 2012

EZ Derm Porcine Xenograft, labeled as the following: a. EZ Derm 3x4 (8x10 cm) Non-Perforated, Part Number: 131703-03; b. EZ Derm 7 x 18 (17 x 46 cm) Non-Perforated, Part Number: 131704-03; c. EZ Derm 2 x 2 (5 x 5 cm) Non-Perforated, Part Number: 131705-03; d. EZ Derm 3 x 48 (8 x 122 cm) Perforated, Part Number: 131710-03; e. EZ Derm 3 x 24 (8 x 61 cm) Perforated, Part Number: 131711-03; f. EZ Derm 3 x 12 (8 x 30 cm) Perforated, Part Number: 131712-03; g. EZ Derm 3 x 4 (8 x 10 cm) Perforated, Part Number: 131713-03; h. EZ Derm 7 x 18 (17 x 46 cm) Perforated, Part Number: 131714-03; i. EZ Derm 2 x 2 (5 x 5 cm) Perforated. Part Number: 131715-03 Product Usage: EZ Derm is a porcine derived xenograft in which the collagen has been cross linked with an aldehyde. EZ Derm (porcine xenograft) can be used for partial thickness skin loss injuries. Use of EZ Derm for burns, donor sites and chronic vascular ulcers reduces pain and fluid loss. EZ Derm can also be used as a temporary cover, or test graft, prior to auto grafting and as a protective covering over perforated auto grafts.

FDA Enforcement
Class II ·Terminated·Molnlycke Health Care, Inc·May 8, 2019

Control Panel REF - 60-02-15: LivaNova SCP Pump Control Panel. REF 60-02-15, IPX2, RxOnly, UDI: 04033817900986

FDA Recall
Terminated ·LivaNova Deutschland GmbH Lindberghstr. 25 Munich Germany·Product code DWA·August 26, 2019

Control Panel REF - 60-02-50: LivaNova SCP Pump Control Panel S5/C5. REF 60-02-50, IPX2, RxOnly, UDI: 04033817900993

FDA Recall
Terminated ·LivaNova Deutschland GmbH Lindberghstr. 25 Munich Germany·Product code DWA·August 26, 2019

Sofia 2 Analyzer Catalog Number 20299 Sofia 2 is a bench top analyzer intended to be used with Cassette-based immunofluorescent in vitro diagnostic assays . Sofia 2 is intended for professional and laboratory use.

FDA Enforcement
Class II ·Terminated·Quidel Corporation·April 4, 2018

Warm Air Model 135 Warming Units.

FDA Recall
Terminated ·Cincinnati Sub-Zero Products·Product code BTE·November 5, 2004

Airways Development LLC WaterPAP Positive Airway Pressure Device Reference #WP-7700.

FDA Recall
Terminated ·Airways Development LLC·Product code BYE·September 24, 2015

Ambu, Positive End Expiratory Pressure (PEEP) Valves, PEEP Valve Spare Part, REF 137 000 501, Manufacturer: Ambu International A/S, DK2750 Ballerup USA: Ambu Inc. (Ambu USA) Linthicum, MD 21090-1356 USA, Made in Denmark

FDA Recall
Terminated ·Ambu Incorporated·Product code BYE·August 21, 2007

Neo-Vent Infant T-Piece Resuscitation Circuit With Infant Mask; Circuit for use on compatible Infant Resuscitators. 15mm OD x 10mm ID connector; REF 0420, Qty:10, Length: 60" (1.5cm), Rx Only.

FDA Recall
Terminated ·Westmed, Inc.·Product code BYE·January 15, 2019

Neo-Vent Infant T-Piece Resuscitation Circuit;Circuit for use on compatible Infant Resuscitators. 15mm OD x 10mm ID connector; REF 0415, Qty:10, Length: 60" (1.5cm), Rx Only.

FDA Recall
Terminated ·Westmed, Inc.·Product code BYE·January 15, 2019