Digital VIPR ROC-9839 Roberts Oxygen Ready to Use Digital VIPR (head only) ROC-9840, Roberts Oxygen Ready to Use Digital VIPR System (with E-size cylinder) MNDR-600, Western Oxytote DTE Digital VIPR (head only) MNDS-602, Western Oxytote DTE Digital VIPR System (with D-size cylinder) MNDS-603, Western Oxytote DTE Digital VIPR System (with E-size cylinder)

FDA Recall
Open, Classified ·Western/Scott Fetzer Company·Product code CAN·January 3, 2023

Western Oxytote DTE Digital VIPR (head only) Model: MNDR-600

FDA Recall
Open, Classified ·Western/Scott Fetzer Company·Product code CAN·October 16, 2021

Vapor-Clean, Part Number 111AU The Vapor-Clean filter is intended to be used to remove unwanted anesthetic gases from the patient breathing circuit. The device uses two anesthetic vapor adsorbent canisters connected to an anesthesia delivery system to prevent unwanted anesthetic vapors emanating from within an anesthesia gas machine from reaching a patient.

FDA Recall
Open, Classified ·Dynasthetics LLC·Product code CBN·May 9, 2022

Western Oxytote DTE Digital VIPR System (with E-size cylinder) Model: MNDS-603

FDA Recall
Open, Classified ·Western/Scott Fetzer Company·Product code CAN·October 16, 2021

Western Oxytote DTE Digital VIPR System (with D-size cylinder) Model: MNDS-602

FDA Recall
Open, Classified ·Western/Scott Fetzer Company·Product code CAN·October 16, 2021

biokitHSV-2 Rapid Test, REF: 300028001

FDA Recall
Open, Classified ·Biokit, S.A. Avinguda De Can Montcau 7 (Barcelona) Llica D'Amunt Spain·Product code LGC·September 28, 2022

CONSTELLATION ULTRAVIT 10K and CONSTELLATION HYPERVIT 20K, Description/REF: 25+ TOTALPLUS CP PAK 20K CPM BWV .9 IU/ 8065000093; 25+ TOTALPLUS CP PAK 20K CPM BV .9 IU/ 8065000095; 27+ TOTALPLUS CP PAK 20K CPM BV .9 IU/ 8065000096; 23GA BEVEL ULTRAVIT 10,000 CPM/ 8065752413; 25+ BEVEL ULTRAVIT 10,000 CPM/ 8065752415; 27+ BEVEL ULTRAVIT 10,000 CPM/ 8065752417; TOTAL PLUS,23G,10K VALVE STD/ 8065752435; TOTAL PLUS,23GA,10K VALVE WD/ 8065752436; TOTAL PLUS,25+,10K VALVE STD/ 8065752437; TOTAL PLUS,25+,10K VALVE WD/ 8065752438; TOTAL PLUS,27+,10K VALVE STD/ 8065752439; 23G CMB PAK 10K CPM,V,STD 0.9/ 8065752448; 23G CMB PAK 10K CPM,V,WA 0.9/ 8065752449; 25+ CMB PAK 10K CPM,V,STD 0.9/ 8065752450; 25+ CMB PAK 10K CPM,V,WA 0.9/ 8065752451; 27+ CMB PAK 10K CPM,V,STD 0.9/ 8065752452; 25+TTLPL VPK 20000CPM BEV VAL/ 8065753106; 27+TTLPL VPK 20000CPM BEV VL/ 8065753109; HYPERVIT 25+BEV 20000 CPM/ 8065830026; HYPERVIT 27+BEV 20000 CPM/ 8065830027; 25+ TTL PLUS VPAK 20000CPM BWV/ 8065830077; 25G VIT 25G OPTICARE EYE HLTH CTR/ 10924-15; VITRECTOMY 25G NORTHSIDE HOSP/ 11220-25; VITRECTOMY 25G NORTHSIDE HOSP/ 11220-27; 23G CONSTELLATION NORTHERN MICH SPPLY AL/ 12568-09; AUS-25GA VIT RET BRISBANE WATERS/ 12641-13; AUS-25GA VIT RET BRISBANE WATERS/ 12641-14; AUS-23GA 10K COMBINED VR PAK NEW CHILDRE/ 12852-16; 23G VIT CONSTELLATION LOMA LINDA COMM HO/ 13501-08; 25+G 20K VIT CONSTELLATION LOMA LINDA CO/ 13502-10; 23G VIT CONSTELLATION VALVED BAYSTATE ME/ 13591-13; 25G CONSTELLATION VALVED BAYSTATE MEDICA/ 13592-15; VITRECTOMY 25G V A HOSPITAL/ 14129-10; J-COMB PAK - 25G 20K CVS NAKAGAMI HOSPIT/ 14283-12; CDN-CVS VIT 25G VE 10K TIMMINS DH/ 14501-09; CDN-CVS VIT 25G+ VE 10K CIUSSS MCQ/ 14512-09; CDN-CVS VIT 25G+ VE 10K CIUSSS MCQ/ 14512-10; CDN-CVS VIT 23G 10K WA SASKATOON HR/ 14532-06; CDN-CVS VIT 23G 10K WA SASKATOON HR/ 14532-07; CDN-CVS VIT 10K 25G+ HSC, ST JOHN'S/ 14540-08; CDN-CVS COMBO 23G VE 10K HD KINGSTON/ 14541-16; CDN-CVS VIT 25G+ 20K BV JEWISH GH/ 14597-07; CDN-CVS VIT 23G 10K ROCKYVIEW HOSPITAL/ 14603-15; CDN-CVS COMBO 25G VE 10K TIMMINS DH/ 14669-10; CDN-CVS COMBO 25G VE 10K TIMMINS DH/ 14669-11; CDN-CVS VIT 23G VE ROYAL ALEXANDRA HOSP/ 14671-09; CDN-CVS VIT 25G+ 10K ROCKYVIEW HOSPITAL/ 14672-11; CDN-CVS VIT 25G+ BWV 20K CUSM/MUHC/ 14873-06; CDN-CVS VIT 25G+ BWV 20K CUSM-MUHC/ 14873-07; CDN-VIT 23G VE 10K ST MICHAEL'S HOSP/ 14955-08; CDN-VIT 23G VE 10K ST MICHAELS HOSP/ 14955-09; CDN-CVS 25G+ VIT VE 10K ST MICHAEL'S/ 14956-07; CDN-CVS 25G+ VIT VE 10K ST MICHAELS/ 14956-08; CDN-CVS VIT 25G+ 10K WESTERN MH/ 15006-06; CDN-CVS VIT 25G+ 20K WA WESTERN MH/ 15006-07; CDN-CVS COMBO 23G 10K ROCKYVIEW HOSPITAL/ 15108-09; CDN-CVS CMB 25G+ V 10K OAKVILLE-TRAFALGA/ 15167-08; 25G PLUS VITRECTOMY PEACE HEALTH ST JOSE/ 15223-13; CDN-VIT 23G 10K GRM741746 CUO-HSS/ 15294-14; CDN-COMBO 23G 10K GRM741759 CUO-HSS/ 15295-12; CDN-CVS VIT 25G+ VE 10K MISERICORDIA HC/ 15318-05; CDN-CVS VIT 25G+ VE 10K MISERICORDIA HC/ 15318-06; CDN-CVS VIT 25G+ VE 10K MISERICORDIA HC/ 15318-07; CDN-CVS COMBO 23G V 10K ST MICHAEL'S HSP/ 15324-07; CDN-COMBO 25G 20K GRM743287 CUO-HSS/ 15421-13; CDN-COMBO 25G 20K GRM743287 CUO-HSS/ 15421-14; CDN-UHN 23G COMBO VE 10K TORONTO WESTERN/ 15455-08; CDN-UHN 23G COMBO VE 10K TORONTO WESTERN/ 15455-09; CDN-UHN 23G COMBO VE 10K TORONTO WESTERN/ 15455-10; CDN-UHN 23G VIT VE 10K TORONTO WESTERN/ 15456-04; CDN-UHN 23G VIT VE 10K TORONTO WESTERN/ 15456-05; CDN-UHN 23G VIT VE 10K TORONTO WESTERN/ 15456-06; CDN-CVS 23G COMBO VE 10K SUNNYBROOK GH/ 15464-05; CDN-CVS 23G VIT VE 10K SUNNYBROOK GH/ 15465-05; 23G VIT PACK CALLAHAN EYE FOUNDATION HOS/ 15491-05; 23G VIT PACK CALLAHAN EYE FOUNDATION HOS/ 15491-06; 27G VIT PACK CALLAHAN EYE FOUNDATION HOS/ 15492-02; 27G VIT PACK CALLAHAN EYE FOUNDATION HOS/ 15492-03; 25G+ VIT PACK CALLAHAN EYE FOUNDATION HO/ 15493-05; 25G+ VIT PACK CALLAHAN EYE FOUNDATION HO/ 15493-06; CDN-CVS VIT 25G+ 10K PASQUA HOSPITAL/ 15525-04; CDN-CVS COMBO 23G VE 10K KENSINGTON EI/ 15552-05; CDN-CVS 23G VIT VE 10K KENSINGTON EYE IN/ 1

FDA Recall
Open, Classified ·Alcon Research LLC·Product code HQB·September 15, 2025

Servo-i Ventilator, Part No. 6487800, UDI Code 07325710000823 - Product Usage: intended for general and critical ventilator care, and it can be used for low end to high end intensive care, in different configurations. It supports a variety of breathing modes and can be used for Neonates, Pediatric and Adults.

FDA Recall
Open, Classified ·Getinge Group Logistics America, LLC·Product code CBK·September 17, 2020

ARTIS is a family of dedicated angiography systems developed for single and biplane diagnostic imaging and interventional procedures including, but not limited to, pediatric and obese patients. Procedures that can be performed with the ARTIS family include cardiac angiography, neuro-angiography, general angiography, rotational angiography, multipurpose angiography and whole body radiographic/fluoroscopic procedures as well as procedures next to the table for i.e., patient extremities. This does not include projection radiography. Additional procedures that can be performed include angiography in the operating room, image guided surgery by X-ray, by image fusion, and by navigation systems. The examination table as an integrated part of the system can be used for X-ray imaging, surgery and interventions. ARTIS can also support the acquisition of position triggered imaging for spatial data synthesis.

FDA Recall
Open, Classified ·Siemens Medical Solutions USA, Inc·Product code OWB·May 15, 2025

Brand Name: EDAN Product Name: Central Monitoring System Model/Catalog Number: MFM-CMS Product Description: MFM-CMS is a central monitoring system product, which can connect and manage information from EDAN medical devices. MFM-CMS offers central management for monitoring information from the medical devices. All these collected information can be displayed, printed, alarmed and recorded. Component: No

FDA Recall
Open, Classified ·Edan Diagnostics·Product code MHX·October 24, 2025

DERMARITE INDUSTRIES SafeWash Saline Saline Wound Flush SafeWash 7.1 oz. Can Sterile 0.9% Sodium Chloride Model Number: 00245

FDA Recall
Open, Classified ·Mckesson Medical-Surgical Inc. Corporate Office 9954 Maryland Drive Deep Run Iii Ste. 4000 Richmond VA 23233·Product code FQH·May 25, 2022

BD Connecta" BD Luer-Lok" 360 REF 394910 UDI-DI code: 00382903949106 BD Connecta" Stopcocks are used to administer fluids or medication through one or two different ports via an IV cannula or extension tube. The ports can be used to sample blood or for hemodynamic monitoring. When used with IV lipid nutritional products, the stopcock device can be used for up to 24 hours.

FDA Recall
Open, Classified ·Product code FMG·May 21, 2026

Giraffe OmniBed Carestation CS1 - Product Usage: The device can be operated as an incubator or as a warmer and can transition from one mode to the other on user s demand. It cannot be operated in both modes at the same time. Incubators and warmers provide heat in a controlled manner to neonates who are unable to thermo regulate based on their own physiology.

FDA Recall
Open, Classified ·GE Healthcare, LLC·Product code FMZ·July 26, 2019

Brand Name: EDAN Product Name: Patient Monitor Model/Catalog Number: X8, X10, X12 Product Description: The X8 X10 X12 Patient Monitor (hereinafter called X series) can perform long-time continuous monitoring of multiple physiological parameters. Also, it is capable of storing, displaying, analyzing and controlling measurements, and it will indicate alarms in case of abnormity so that doctors and nurses can deal with them in time. Component: No

FDA Recall
Open, Classified ·Edan Diagnostics·Product code MHX·October 24, 2025

Brand Name: EDAN Product Name: Patient Monitor Model/Catalog Number: iX10, iX12, iX15 Product Description: The iX series Patient Monitors including iX10, iX12, iX15 can perform long-time continuous monitoring of multiple physiological parameters. Also, it is capable of storing, displaying, analyzing and controlling measurements, and it will indicate alarms in case of abnormalities so that doctors and nurses can respond to the patient's situation as appropriate. Component: No

FDA Recall
Open, Classified ·Edan Diagnostics·Product code MHX·October 24, 2025

Liko Universal Twinbar 670 QRH, an accessory that can be used together with most Liko lifts, model numbers 3156087 and P3156087.

FDA Recall
Open, Classified ·Baxter Healthcare Corporation·Product code FSA·February 21, 2022

Brand Name: EDAN Product Name: Patient Monitor Model/Catalog Number: iM50, iM60, iM70, iM80 Product Description: The iM series Patient Monitor including iM50, iM60, iM70 and iM80 can perform long-time continuous monitoring of multiple physiological parameters. Also, it is capable of storing, displaying, analyzing and controlling measurements, and it will indicate alarms in case of abnormalities so that doctors and nurses can respond to the patient's situation as appropriate. Component: No

FDA Recall
Open, Classified ·Edan Diagnostics·Product code MHX·October 24, 2025

Tempus LS-Manual Defibrillator Model 00-3020 The Tempus LS-Manual is a defibrillator that can deliver a shock in manual or Pacemaker mode

FDA Recall
Open, Classified ·Remote Diagnostic Technologies Ltd. Farnborough Aerospace Centre Aerospace Boulevard Farnborough United Kingdom·Product code LDD·October 28, 2024

Captiflex Snares, Single-Use Polypectomy Snare consists of a flexible wire cable and loop which can be extended and retracted from the snares flexible outer sheath using a three-ring handle. The inner diameter of the sheath is PolyGlide" Lubricant coated to provide minimal friction during extension and retraction of the loop from the sheath. When passed through an endoscope the snare can be activated to deliver a monopolar electrical current to cut and cauterize tissue with the loop.

FDA Recall
Open, Classified ·Boston Scientific Corporation·Product code FDI·July 6, 2020

Puritan Bennett 500 Series Ventilators (Description/REF): PURITAN BENNETT 560 VENTILATOR/4096600, PURITAN BENNETT PB560 VENTILATOR EU-DIV/4096600-01, PURITAN BENNETT 560 VENTILATOR JAPAN/4096600-02, PURITAN BENNETT 560 VENTILATOR APAC/4096600-03, Puritan Bennett 560 Ventilator LATAM/4096600-04, Puritan Bennett 560 Ventilator EMEA/4096600-05, Puritan Bennett 560 Ventilator CAN ANZ/4096600-06, Puritan Bennett 540 Ventilator USA/4097100 Puritan Bennett 520 Ventilator/4098300, Puritan Bennett 520 Ventilator EU-DIV/4098300-01, Puritan Bennett 520 Ventilator Japan/4098300-02, Puritan Bennett 520 Ventilator APAC/4098300-03, Puritan Bennett 520 Ventilator EMEA/4098300-05, Puritan Bennett 520 Ventilator CAN/ANZ/4098300-06, DL4096600 DL PB560 VENTILATOR/DL4096600, DL4096600-06 RFB PB560 VENT CAN ANZ/DL4096600-06, REFURBISHED PB540 VENTILATOR/DL4097100, Puritan Bennett 540 Ventilator Refurbished/DS4097100

FDA Recall
Open, Classified ·Covidien·Product code CBK·June 24, 2024