18 results
·
22ms
·
Sources: EU EUDAMED, US FDA
Filters
Regulation: Us FDA
×
IDS-iSYS Ostase BAP
FDA 510(k)
FDA Class 2
·Clinical Chemistry
Blade Scalpel
FDA UDI
KATENA PRODUCTS, INC.·00841668113523·SLIT BLADE 3.0MM STR (BX/5)
DESS dental smart solutions
FDA UDI
TERRATS MEDICAL SL.·08435457205654·Conical Bl
CHEN IMPLANT ELEVATOR
FDA UDI
W.H. Holden, Inc.·D9282004750·
Helical Ridge
FDA UDI
Medshape, Inc.·M97014002004750·4.75MM X 20MM PEEK Interference Screw
CHAD THERAPEUTICS OXYPENUMATIC CYPRESS MODEL 511
FDA 510(k)
FDA Class 2
·Anesthesiology
BRACHYSEED
FDA 510(k)
FDA Class 2
·Radiology
SPECTRUM INFUSION PUMP
FDA Adverse Event
Malfunction
·BAXTER HEALTHCARE CORP.·Product code FRN·October 8, 2014
BD PEGASUS¿ SAFETY CLOSED IV CATHETER SYSTEM
FDA Adverse Event
Malfunction
·BECTON DICKINSON MEDICAL DEVICES CO., LTD. SUZHOU·Product code FOZ·January 13, 2022
STERIS SYSTEM 1E
FDA Adverse Event
STERIS CORPORATION - HOPKINS·Product code MED·October 24, 2014
PROXIMATE** RELOADABLE LINEAR CUTTER WITH SAFTEY LOCK-OUT
FDA Adverse Event
Malfunction
·ETHICON ENDO-SURGERY, LLC.·Product code GDW·August 11, 2011
POWERED WHEELCHAIR
FDA Adverse Event
Malfunction
·INVACARE TAYLOR STREET·Product code ITI·July 1, 2013
AMPLATZER SEPTAL OCCLUDER
FDA Adverse Event
Malfunction
·ABBOTT MEDICAL·Product code MLV·May 22, 2023
AMPLATZER SEPTAL OCCLUDER
FDA Adverse Event
Malfunction
·ABBOTT MEDICAL·Product code MLV·May 22, 2023
PROXIMATE*HCS HEMORR CIR STAPL (EXACT CODE UNKNOWN
FDA Adverse Event
Injury
·ETHICON ENDO-SURGERY, LLC.·Product code GDW·August 5, 2019
Spacelabs Medical Patient Monitor is a Physiological, Patient monitor With Arrhythmia Detection or Alarms. The Models are 91367, 91369, 91370, 91387, and 91393 are sold with Perioperative Mode (option D), which includes Start case/End case functionality, Upgrade Kit 040-1548-00. Spacelabs Healthcare patient monitors, functioning as either bedside or central monitors; passively display data generated by Spacelabs Healthcare parameter modules, Flexports interfaces, and other SDLC based products in the form of waveform and numeric displays, trends and alarms. Key monitored parameters available on the models 91367, 91369, 91370 and 91387, when employing the Spacelabs Command Module, consist of ECG, respiration, invasive and noninvasive blood pressure, Sp02, temperature and cardiac output. Additional parameters and interfaces to other systems are also available depending on the parameter modules employed
FDA Enforcement
Class II
·Terminated·Spacelabs Healthcare Inc·October 1, 2014
Medrad Continuum MR Infusion system- non-wireless system The MEDRAD Continuum MR Infusion System is designed for patients who require medications and other fluids during an MR procedure. It is intended to provide infusion therapy directly prior to, during and immediately after the MR procedure functioning while either stationary or mobile. It is not intended to provide long-term patient care outside the MR environment. The system is to be used by trained medical staff, primarily critical care, emergency room and radiology nursing staff.
FDA Enforcement
Class II
·Terminated·Bayer Corp·June 11, 2014
Exactech Equinoxe REVERSE SHOULDER,36mm Humeral Liner: a) +0mm, Item Number 320-36-00, b) +2.5mm, Item Number 320-36-03; Shoulder Arthroplasty
FDA Enforcement
Class II
·Ongoing·Exactech, Inc.·April 10, 2024