PROXIMATE*HCS HEMORR CIR STAPL (EXACT CODE UNKNOWN
Report
- Report Number
- 3005075853-2019-21051
- Event Type
- Injury
- Date Received
- August 5, 2019
- Date of Event
- January 1, 2006
- Report Date
- July 12, 2019
- Manufacturer
- ETHICON ENDO-SURGERY, LLC.
- Product Code
- GDW
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- NY, US
- Reporter Occupation
- OTHER
Narratives
(B)(4). DATE OF EVENT: PUBLICATION YEAR OF 2006. BATCH # UNK. THIS REPORT IS RELATED TO A JOURNAL ARTICLE; THEREFORE, NO PRODUCT WILL BE RETURNED FOR ANALYSIS AND THE MANUFACTURING RECORDS CANNOT BE REVIEWED AS THE LOT/BATCH NUMBER HAS NOT BEEN PROVIDED. (B)(4).
IT WAS REPORTED VIA LITERATURE ENTITLED: HEMORRHOIDOPEXY STAPLE LINE HEIGHT PREDICTS RETURN TO WORK AUTHOR : MARGARET D. PLOCEK, M.D., LAURIE ANN KONDYLIS, R.N., B.S., NADINE DUHAN-FLOYD, M.D., JOHN C. REILLY, M.D., DANIEL P. GEISLER, M.D., PHILIP D. KONDYLIS, M.D. CITATION: DIS COLON RECTUM 2006; 49: 1905¿1909; DOI: 10.1007/S10350-006-0724-X; PUBLISHED ONLINE: 13 OCTOBER 2006. THE PURPOSE OF THIS STUDY WAS TO FURTHER INVESTIGATE AND REFINE THE ROLE OF STAPLE HEIGHT IN THE PREDICTION OF POSTOPERATIVE OUTCOMES. FROM JULY 2002 TO OCTOBER 2004, 75 PATIENTS WITH A MEDIAN AGE OF 49 YEARS (RANGE, 25-87) (MALE N=46, FEMALE N=29) WITH SYMPTOMATIC GRADE 3 AND 4 MIXED HEMORRHOIDS UNDERWENT STAPLED HEMORRHOIDOPEXY. A 33-MM PROXIMATE HCS HEMORRHOIDAL CIRCULAR STAPLER (ETHICON ENDO-SURGERY, INC. CINCINNATI, OH) WAS USED FOR ALL PROCEDURES. THE OPEN STAPLER WAS PASSED THROUGH THE PURSESTRING WHERE IT WAS THEN SECURED. THE STAPLER WAS HELD IN THE CLOSED POSITION FOR 45 SECONDS BEFORE FIRING. COMPLICATIONS INCLUDED PAIN (N=3) WHICH REQUIRED READMISSIONS FOR PAIN CONTROL, ACUTE POSTOPERATIVE ANAL FISSURES (N=3), POSTOPERATIVE BLEEDS (N=2) (WITH ONE REQUIRING EXAMINATION UNDER ANESTHESIA WITHOUT INTERVENTION), SELF-LIMITED CASE OF SUBCUTANEOUS EMPHYSEMA (N=1), FECAL IMPACTION (N=1) WHICH REQUIRED ADMISSION, POSTOPERATIVE SEEPAGE (N=1) AND RECURRENCE OF INTERNAL HEMORRHOIDAL PROLAPSE (N=3). IN CONCLUSION, A HEMORRHOIDOPEXY STAPLE LINE =22 MM ABOVE THE DENTATE LINE CORRELATES WITH A SIGNIFICANTLY SHORTER NEED FOR POSTOPERATIVE NARCOTICS (P = 0.024) AND AN EARLIER RETURN TO WORK (P = 0.017). STAPLE LINE DISTANCE ABOVE THE DENTATE LINE MEANINGFULLY IMPACTS COMFORT-BASED OUTCOMES.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 654664 | PROXIMATE*HCS HEMORR CIR STAPL (EXACT CODE UNKNOWN | STAPLE, IMPLANTABLE | GDW | ETHICON ENDO-SURGERY, LLC. |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | Hospitalization| R |