13 results · 30ms · Sources: EU EUDAMED, US FDA

Get notified when this changes

We'll email you when new records match this search — new devices, new clearances, certificate changes, or withdrawals.

INTERTAN CHS LOCKING PLATE SYSTEM PROX FEM PLATES/SCREW

FDA 510(k)
FDA Class 2 ·Orthopedic

OPTETRAK B-SERIES TOTAL KNEE SYSTEM

FDA 510(k)
FDA Class 2 ·Orthopedic

MICROPLEX COIL SYSTEM (MCS)

FDA 510(k)
FDA Class 2 ·Neurology

HAHN TAPERED IMPLANT 3.5 X 11.5MM

FDA Adverse Event
Injury ·PRISMATIK DENTALCRAFT, INC.·Product code DZE·February 3, 2023

HAHN TAPERED IMPLANT 3.5 X 11.5 MM

FDA Adverse Event
Malfunction ·PRISMATIK DENTALCRAFT, INC.·Product code DZE·February 16, 2021

WAVEWRITER ALPHA

FDA Adverse Event
Injury ·BOSTON SCIENTIFIC NEUROMODULATION·Product code LGW·November 8, 2023

ALIGN TO URETHRAL SUPPORT SYSTEM

FDA Adverse Event
Injury ·BARD SHANNON LTD·Product code FTL·April 24, 2013

MANUAL ORTHOPEDIC SURGICAL INSTRUMENT

FDA Adverse Event
Malfunction ·MEDTRONIC SOFAMOR DANEK INSTRUMENT MANUFACTURING·Product code LXH·May 6, 2011

NXSTAGE SYSTEM ONE

FDA Adverse Event
Injury ·NXSTAGE MEDICAL, INC.·Product code KDI·July 21, 2008

VERCISE CARTESIA

FDA Adverse Event
Injury ·BOSTON SCIENTIFIC NEUROMODULATION·Product code NHL·May 29, 2024

INFINION? CX

FDA Adverse Event
Malfunction ·BOSTON SCIENTIFIC NEUROMODULATION CORPORATION·Product code LGW·November 29, 2025

OPTETRAK Comprehensive Knee System, labeled as the following: a. OPTETRAK All-polyethylene CR Tibial Components, with Product Line Numbers: 200-11-XX, 200-12-XX, 200-13-XX, 200-14-XX, 200-15-XX, 200-16-XX; b. OPTETRAK All-polyethylene PS Tibial Components, with Product Line Numbers: 204-11-XX, 204-12-XX, 204-13-XX, 204-14-XX, 204-15-XX, 204-16-XX; c. OPTETRAK HI-FLEX PS Polyethylene Tibial Inserts, with Product Line Numbers: 244-20-XX, 244-21-XX, 244-22-XX, 244-23-XX, 244-24-XX, 244-25-XX; d. OPTETRAK CR Tibial Inserts, with Product Line Numbers: 200-21-XX, 200-22-XX, 200-23-XX, 200-24-XX, 200-25-XX, 200-26-XX, 200-50-XX, 200-51-XX; e. OPTETRAK CR Tibial Slope + Insert, with Product Line Numbers: 200-56-XX, 200-57-XX, 200-61-XX, 200-62-XX, 200-63-XX, 200-64-XX, 200-65-XX; f. OPTETRAK CR Tibial Slope ++ Insert, with Product Line Numbers: 200-57-XX, 200-71-XX, 200-72-XX, 200-73-XX, 200-74-XX, 200-75-XX; g. OPTETRAK PS Tibial Inserts, with Product Line Numbers: 204-21-XX, 204-22-XX 204-23-XX, 204-24-XX, 204-25-XX, 204-26-XX, 204-50-XX, 204-51-XX; h. OPTETRAK "MOMB" Non-Mod Molded Insert, with Product Line Numbers: 204-91-XX, 204-92-XX, 204-93-XX, 204-94-XX, 204-95-XX; i. OPTETRAK CC Tibial Insert, with Product Line Numbers: 208-21-XX, 208-22-XX, 208-23-XX, 208-24-XX, 208-25-XX, 208-51-XX; j. OPTETRAK B-Series PS Tibial Insert, with Product Line Numbers: 224-21-XX, 224-22-XX, 224-23-XX, 224-24-XX. Affected 510(k) numbers include: K932690, K933494, K932776, K011976, K082022, K933610, K030686, K954208, K010434, K033883. NOTE: Information reflects Exactech recall expansion initiated on 02/07/2022.

FDA Recall
Open, Classified ·Exactech, Inc.·Product code JWH·August 30, 2021

OPTETRAK Comprehensive Knee System, labeled as the following: a. OPTETRAK All-polyethylene CR Tibial Components, with Product Line Numbers: 200-11-XX, 200-12-XX, 200-13-XX, 200-14-XX, 200-15-XX, 200-16-XX; b. OPTETRAK All-polyethylene PS Tibial Components, with Product Line Numbers: 204-11-XX, 204-12-XX, 204-13-XX, 204-14-XX, 204-15-XX, 204-16-XX; c. OPTETRAK HI-FLEX PS Polyethylene Tibial Inserts, with Product Line Numbers: 244-20-XX, 244-21-XX, 244-22-XX, 244-23-XX, 244-24-XX, 244-25-XX; d. OPTETRAK CR Tibial Inserts, with Product Line Numbers: 200-21-XX, 200-22-XX, 200-23-XX, 200-24-XX, 200-25-XX, 200-26-XX, 200-50-XX, 200-51-XX; e. OPTETRAK CR Tibial Slope + Insert, with Product Line Numbers: 200-56-XX, 200-57-XX, 200-61-XX, 200-62-XX, 200-63-XX, 200-64-XX, 200-65-XX; f. OPTETRAK CR Tibial Slope ++ Insert, with Product Line Numbers: 200-57-XX, 200-71-XX, 200-72-XX, 200-73-XX, 200-74-XX, 200-75-XX; g. OPTETRAK PS Tibial Inserts, with Product Line Numbers: 204-21-XX, 204-22-XX 204-23-XX, 204-24-XX, 204-25-XX, 204-26-XX, 204-50-XX, 204-51-XX; h. OPTETRAK "MOMB" Non-Mod Molded Insert, with Product Line Numbers: 204-91-XX, 204-92-XX, 204-93-XX, 204-94-XX, 204-95-XX; i. OPTETRAK CC Tibial Insert, with Product Line Numbers: 208-21-XX, 208-22-XX, 208-23-XX, 208-24-XX, 208-25-XX, 208-51-XX; j. OPTETRAK B-Series PS Tibial Insert, with Product Line Numbers: 224-21-XX, 224-22-XX, 224-23-XX, 224-24-XX. Affected 510(k) numbers include: K932690, K933494, K932776, K011976, K082022, K933610, K030686, K954208, K010434, K033883. NOTE: Information reflects Exactech recall expansion initiated on 02/07/2022.

FDA Enforcement
Class II ·Ongoing·Exactech, Inc.·October 13, 2021