FDA Adverse Event Malfunction Summary report: N

HAHN TAPERED IMPLANT 3.5 X 11.5 MM

MDR report key: 11335846 · Received February 16, 2021

Report

Report Number
3011649314-2021-00043
Event Type
Malfunction
Date Received
February 16, 2021
Date of Event
October 25, 2020
Report Date
September 3, 2021
Manufacturer
PRISMATIK DENTALCRAFT, INC.
Product Code
DZE
PMA / PMN Number
K143353
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
CA, US
Reporter Occupation
DENTIST

Narratives

Additional Manufacturer Narrative · 0

THE DEVICE INVESTIGATION HAS BEEN COMPLETED AND THE RESULTS ARE AS FOLLOWS: INVESTIGATION METHODS/RESULTS: DEVICE WAS NOT RETURNED FOR INVESTIGATION. HOWEVER, THE NON-VISUAL DEVICE INVESTIGATION HAS BEEN COMPLETED. DEVICE HISTORY RECORD REVIEW: THE DHR WAS REVIEWED FOR LOT# 6080434 AND THERE WAS NO EVIDENCE DISCOVERED TO INDICATE THAT A PRODUCT DEFECT OR NON-CONFORMITY CONTRIBUTED TO THE ISSUE. THE PART MET ALL THE CRITERIA CALLED FOR IN THE PRODUCTION ROUTER. STOCK PRODUCT REVIEW: THERE WAS NO STOCK PRODUCT FROM LOT# 6080434 AVAILABLE FOR REVIEW. ROOT CAUSE: PER THE REPORTED INFORMATION, THE PATIENT HAD TYPE IV BONE QUALITY. IT HAS BEEN SHOWN THAT THE QUALITY AND QUANTITY OF BONE AVAILABLE AT THE IMPLANT SITE ARE VERY IMPORTANT PATIENT FACTORS IN DETERMINING THE SUCCESS OF DENTAL IMPLANTS. IT IS DIFFICULT TO OBTAIN IMPLANT ANCHORAGE IN BONE THAT IS NOT VERY DENSE. TYPE IV: VERY THIN CORTICAL BONE WITH LOW DENSITY TRABECULAR BONE OF POOR STRENGTH. THEREFORE, THE PATIENT'S BONE QUALITY MAY HAVE BEEN A FACTOR. "FAILURE TO OSSEOINTEGRATE" IS A COMMON COMPLAINT IN REGARDS TO IMPLANT FAILURE. THIS OCCURS WHEN THE PATIENT'S BONE DOES NOT INTEGRATE WITH THE IMPLANT SURFACE. THE POSSIBLE RESPONSES TO THIS COMPLAINT COULD BE ATTRIBUTED TO VARIOUS CAUSES. ALTHOUGH THE ROOT CAUSE FOR FAILURE TO OSSEOINTEGRATE IS INCONCLUSIVE AND SPECIFIC TO EACH CASE, PROBABLE CAUSES COULD BE THE LOSS OF PRIMARY STABILITY AT THE OSTEOTOMY SITE DUE TO INSUFFICIENT BONE OR POOR BONE QUALITY; EITHER THE BONE WAS TOO SOFT OR THE OPERATOR ERRED IN CREATING AN OSTEOTOMY BIGGER THAN THE SIZE OF THE IMPLANT DIAMETER. PREMATURE LOADING, PATIENT'S HEALTH, PERI-IMPLANTITIS, SMOKING, AND LACK OF ORAL HYGIENE MAY ALSO BE CONTRIBUTING FACTORS. IFU 3027904 REV 2.0 (HAHN TAPERED IMPLANT SYSTEM) CONTAINS THE FOLLOWING STATEMENT IN PRECAUTION SECTION SURGICAL PROCEDURES: "MINIMIZING TISSUE DAMAGE IS CRUCIAL TO SUCCESSFUL IMPLANT OSSEOINTEGRATION. IN PARTICULAR, CARE SHOULD BE TAKEN TO ELIMINATE SOURCES OF INFECTION, CONTAMINANTS, SURGICAL AND THERMAL TRAUMA. RISK OF OSSEOINTEGRATION FAILURE INCREASES AS TISSUE TRAUMA INCREASES. ALL DRILLING PROCEDURES SHOULD BE PERFORMED AT 2000 RPM OR LESS UNDER CONTINUAL AND COPIOUS IRRIGATION. ALL SURGICAL INSTRUMENTS USED MUST BE IN GOOD CONDITION AND SHOULD BE USED CAREFULLY TO AVOID DAMAGE TO IMPLANTS OR OTHER COMPONENTS. IMPLANTS SHOULD BE PLACED WITH SUFFICIENT STABILITY; HOWEVER, EXCESSIVE INSERTION TORQUE MAY RESULT IN IMPLANT FRACTURE, OR FRACTURE OR NECROSIS OF THE IMPLANT SITE. THE PROPER SURGICAL PROTOCOL SHOULD BE STRICTLY ADHERED TO." THE IFU ALSO CONTAINS THE FOLLOWING STATEMENT IN WARNING SECTION: "ABSOLUTE SUCCESS CANNOT BE GUARANTEED. FACTORS SUCH AS INFECTION, DISEASE AND INADEQUATE BONE QUALITY AND/OR QUANTITY CAN RESULT IN OSSEOINTEGRATION FAILURES FOLLOWING SURGERY OR INITIAL OSSEOINTEGRATION." THE IFU ALSO CONTAINS THE FOLLOWING STATEMENT IN WARNING SECTION: "THE IMPLANT SITE SHOULD BE INSPECTED FOR ADEQUATE BONE BY RADIOGRAPHS, PALPATIONS AND VISUAL EXAMINATION. DETERMINE THE LOCATION OF NERVES AND OTHER VITAL STRUCTURES AND THEIR PROXIMITY TO THE IMPLANT SITE BEFORE ANY DRILLING TO AVOID POTENTIAL INJURY, SUCH AS PERMANENT NUMBNESS TO THE LOWER LIP AND CHIN."

Additional Manufacturer Narrative · 1

THE DEVICE HAS NOT BEEN RETURNED. WHEN/IF THE DEVICE IS RETURNED FOR EVALUATION, THE NEW INFORMATION WILL BE SUBMITTED IN A SUPPLEMENTAL REPORT.

Description of Event or Problem · 1

IT WAS REPORTED THAT A HAHN TAPERED IMPLANT FAILED. THE IMPLANT WAS PLACED ON (B)(6) 2020 AT TOOTH LOCATION #12. THE PATIENT RETURNED ON (B)(6) 2020 FOR A FOLLOW-UP VISIT, AND PRESENTED WITH NO SYMPTOMS. AFTER EXAMINATION, THE DOCTOR NOTED THAT THE IMPLANT WAS SURROUNDED BY SOFT TISSUE, AND THAT THE IMPLANT HAD FAILED TO INTEGRATE. THE PATIENT RETURNED AGAIN ON (B)(6) 2020. DURING EXAMINATION, THE DOCTOR NOTED THAT AS THE COVER SCREW WAS BEING REMOVED, THE IMPLANT CAME OUT. THE PATIENT IS CURRENTLY REPORTED TO BE IN GOOD STANDING. THE PATIENT HAS TYPE D4 BONE QUALITY, AND HAS NO RELATIVE MEDICAL OR DENTAL HISTORY. THERE WAS NO ABNORMALITY NOTED WITH THE IMPLANT ITSELF.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
228063 HAHN TAPERED IMPLANT 3.5 X 11.5 MM HAHN TAPERED IMPLANT DZE PRISMATIK DENTALCRAFT, INC. 70-1154-IMP0006 6080434

Patients

Seq Age Sex Outcome Treatment
1