ACCESS THYROGLOBULIN REAGENTS ON THE ACCESS IMMUNOASSAY SYSTEMS
FDA 510(k)
FDA Class 2
·Immunology
LIFEMATE MLA MULTI-LINE ADAPTOR; LIFEMATE SFR STERILE FLUID RESERVOIR
FDA 510(k)
FDA Class 2
·Gastroenterology, Urology
DENTALMATIC TI PROSTHESIS AND DENTALMATIC TI-A PROSTHETIC
FDA 510(k)
FDA Class 2
·Dental
HANDLE FOR HOOK OR SCREW HOLDER
FDA Adverse Event
Malfunction
·WRIGHTS LANE SYNTHES USA PRODUCTS LLC·Product code LXH·January 29, 2020
LOCKING TITANIUM ADAPTER
FDA Adverse Event
Malfunction
·BAXTER HEALTHCARE - SWINFORD·Product code KDJ·April 2, 2013
9900
FDA Adverse Event
Malfunction
·GE OEC MEDICAL SYSTEMS (SLC)·Product code JAA·March 16, 2011
ACCU-CHEK RAPID D INFUSION SET
FDA Adverse Event
Injury
·DISETRONIC MEDICAL SYSTEMS·Product code FPA·April 18, 2008
SPECTRA WAVEWRITER?
FDA Adverse Event
Injury
·BOSTON SCIENTIFIC NEUROMODULATION CORPORATION·Product code LGW·March 2, 2026
HANDLE FOR HOOK OR SCREW HOLDER
FDA Adverse Event
Malfunction
·WRIGHTS LANE SYNTHES USA PRODUCTS LLC·Product code LXH·September 3, 2019
PANEL PHOENIX NMIC/ID-307
FDA Adverse Event
Malfunction
·BECTON DICKINSON & CO. (SPARKS)·Product code LON·December 21, 2023
Advantage Workstation Volume Share 2 (versionAW4.4_04) with Volume Viewer 3 and 3.1 (version7.0 to version7.5 and version 8.1) and only when or more of these applications is installed: " VesselIQ Xpress or AVA Xpress " CardIQ Xpress Pro or Plus " CardEP " CardIQ Fusion PET or SPECT Advantage Workstations Volume Share (v.AW4.3) and AW4.2 (version4.2-05 and above) provided with Volume Viewer 2(version6.0 to version6.11) and only when one or both of these applications is installed: " CardIQ Xpress Pro or Plus " CardEP Advantage Workstations AW Volume Share 2 (AW version 4.4). ONLY IF ONE OF FOLLOWING APPLICATIONS IS INSTALLED: VesselIQ Xpress or AVA Xpress CardIQ Xpress Pro or Plus CardEP CardIQ Fusion PET or SPECT provided with Volume Viewer 3 and 3.1 from versions 7.0 to 7.5 and 8.1. To verify the version installed on your system: Select the Admin menu from the Patient list page. Then select Display Configuration. You will find the version of your system in Installed Application(s). This version will appear as vxtl_7.x or vxtl_8.x. Intended use: K993792: Smart Vessel Analysis (Smart VA) is a software post-processing option for the Advantage Workstation (AW) platform, which can be used in the analysis of 3D angiography data. It provides a number of display, measurement and batch filming/archive features and will aid physicians in studying user-selected vessels for stenosis analysis, pre/post stent planning and directional vessel tortuosity visualization. K031261: Card EP is a post processing software option for the Advantage Workstation (AW) Platform. This product can be used for the analysis of CT angiographic images for the assessment of the heart to include the atria, pulmonary veins, and coronary sinus. It provides quantitative analysis tools which include a number of display, measurement and model export capabilities. This product can be used to aid trained physicians in the visualization and assessment of cardiac anatomy. K041267: CardIQ Analysis III is a CT image analysis software package, which allows the visualization of 2D and 3D medical image data of the heart derived from DICOM 3.0 compliant CT scans for the purpose of cardiovascular disease assessment. It provides functionally for 2D/3D rendering, assessment of calcified and non-calcified plaque to determine the densities of the plaque within a coronary artery, ventricular function of the heart, and measurement tools to detect coronary artery stenosis. This product can be used to aid a trained physician to process, render, review, archive, print and visualizing cardiac anatomy and coronary vessels. CardIQ Analysis II will run on the AW workstation, scanner operator console and PACS system. K061370: CardIQ Fusion is intended to provide an optimized non-invasive application to analyze vascular anatomy and pathology, aid in the assessment of functional data e.g. PET perfusion, and aid in tailoring treatment plans based on the fused anatomical and functional information. Anatomical data could be from a set of Computed Tomography (CT) Angiographic images while functional data could be from PET, SPECT, or processed CT data. CardIQ Fusion is a software post-processing package for the Advantage Workstation (AW) platform, PET/CT and CT scanners and PACS reading stations. It is an additional tool for the analysis of 3D CT angiographic cardiac images/data providing a number of display, measurements and batch filming/archive features to study user-selected vessels. Also included is the capability to visualize reformatted CT/PET/SPECT perfusion and viability data. Finally, it provides different ways of visualizing CT anatomy fused with PET/SPECT functional information. With CardIQ Fusion, clinicians have the opportunity to overlay functional information over the (CT) anatomy of a patient's heart, and thus, they can potentially tailor their decision for that particular patient. CardIQ Fusion provides the visualization of the vessels in severa
FDA Recall
Terminated
·GE Healthcare, LLC·Product code LLZ·May 29, 2012
Brand Name: Canturio¿ Smart Extension Product Name: CSE Implant Model/Catalog Number: 43-5570-030-14 Product Description: Tibial stem extension for use with Zimmer Persona¿ Personalized Knee System; 14mm diameter x 30mm height. Implantable device with integrated electronics for passive kinematic data collection. Single-use, sterile. Packaged in a sterile blister and outer shelf pack. Sold individually. Component: Yes. The Canturio¿ Smart Extension (CSE) is a tibial implant component intended for use with the Zimmer Persona¿ Personalized Knee System.
FDA Enforcement
Class II
·Ongoing·Canary Medical, Inc.·July 16, 2025
Advantage Workstation Volume Share 2 (versionAW4.4_04) with Volume Viewer 3 and 3.1 (version7.0 to version7.5 and version 8.1) and only when or more of these applications is installed: " VesselIQ Xpress or AVA Xpress " CardIQ Xpress Pro or Plus " CardEP " CardIQ Fusion PET or SPECT Advantage Workstations Volume Share (v.AW4.3) and AW4.2 (version4.2-05 and above) provided with Volume Viewer 2(version6.0 to version6.11) and only when one or both of these applications is installed: " CardIQ Xpress Pro or Plus " CardEP Advantage Workstations AW Volume Share 2 (AW version 4.4). ONLY IF ONE OF FOLLOWING APPLICATIONS IS INSTALLED: ¿ VesselIQ Xpress or AVA Xpress ¿ CardIQ Xpress Pro or Plus ¿ CardEP ¿ CardIQ Fusion PET or SPECT provided with Volume Viewer 3 and 3.1 from versions 7.0 to 7.5 and 8.1. To verify the version installed on your system: Select the Admin menu from the Patient list page. Then select Display Configuration. You will find the version of your system in Installed Application(s). This version will appear as vxtl_7.x or vxtl_8.x. Intended use: K993792: Smart Vessel Analysis (Smart VA) is a software post-processing option for the Advantage Workstation (AW) platform, which can be used in the analysis of 3D angiography data. It provides a number of display, measurement and batch filming/archive features and will aid physicians in studying user-selected vessels for stenosis analysis, pre/post stent planning and directional vessel tortuosity visualization. K031261: Card EP is a post processing software option for the Advantage Workstation (AW) Platform. This product can be used for the analysis of CT angiographic images for the assessment of the heart to include the atria, pulmonary veins, and coronary sinus. It provides quantitative analysis tools which include a number of display, measurement and model export capabilities. This product can be used to aid trained physicians in the visualization and assessment of cardiac anatomy. K041267: CardIQ Analysis III is a CT image analysis software package, which allows the visualization of 2D and 3D medical image data of the heart derived from DICOM 3.0 compliant CT scans for the purpose of cardiovascular disease assessment. It provides functionally for 2D/3D rendering, assessment of calcified and non-calcified plaque to determine the densities of the plaque within a coronary artery, ventricular function of the heart, and measurement tools to detect coronary artery stenosis. This product can be used to aid a trained physician to process, render, review, archive, print and visualizing cardiac anatomy and coronary vessels. CardIQ Analysis II will run on the AW workstation, scanner operator console and PACS system. K061370: CardIQ Fusion is intended to provide an optimized non-invasive application to analyze vascular anatomy and pathology, aid in the assessment of functional data e.g. PET perfusion, and aid in tailoring treatment plans based on the fused anatomical and functional information. Anatomical data could be from a set of Computed Tomography (CT) Angiographic images while functional data could be from PET, SPECT, or processed CT data. CardIQ Fusion is a software post-processing package for the Advantage Workstation (AW) platform, PET/CT and CT scanners and PACS reading stations. It is an additional tool for the analysis of 3D CT angiographic cardiac images/data providing a number of display, measurements and batch filming/archive features to study user-selected vessels. Also included is the capability to visualize reformatted CT/PET/SPECT perfusion and viability data. Finally, it provides different ways of visualizing CT anatomy fused with PET/SPECT functional information. With CardIQ Fusion, clinicians have the opportunity to overlay functional information over the (CT) anatomy of a patient's heart, and thus, they can potentially tailor their decision for that particular patient. CardIQ Fusion provides the visualization of the vessels in severa
FDA Enforcement
Class II
·Terminated·GE Healthcare, LLC·December 26, 2012
The Spirit TM Select bed is a Med-Surg bed intended to support and transport low to moderate acuity patients in the medical and/or surgical area of the hospital. The Spirit Select bed is also intended for use as a general purpose, variable height hospital bed for general care, post-operative and general medicine wards. The product has a 500 pound safe working load and includes the standard features of an integrated scale and bed exit system, enhanced footboard staff controls for scale and bed exit system and a low bed height of 10.75 inches.
FDA Enforcement
Class II
·Terminated·CHG Hospital Beds Inc·March 23, 2016
Spirit Plus Bed, A-C Powered Hospital Bed
FDA Enforcement
Class II
·Terminated·CHG Hospital Beds Inc·August 10, 2016
Spirit Select Bed, A-C Powered Hospital Bed
FDA Enforcement
Class II
·Terminated·CHG Hospital Beds Inc·August 10, 2016
cobas 6000 Modular Series system; Part Numbers: 1. 04745914001 cobas c 501 module; 2. 05036453001 cobas 6000 UL c 501 + Core Fix configuration; 3. 05036453692 - cobas 6000 UL + CORE CU; and 4. 05860636001 cobas 6000 c 501 (UL) V
FDA Enforcement
Class II
·Terminated·Roche Diagnostics Corporation·March 14, 2018
Smiths Medical Medfusion Model 4000 Syringe pump, Item Numbers: a) 4000-0101-249, b) 4000-0101-50, c) 4000-0101-51, d) 4000-0105-249, e) 4000-0105-50, f) 4000-0105-51, g) 4000-0105-78, h) 4000-0106-00, i) 4000-0106-01, j) 4000-0106-231,
FDA Enforcement
Class II
·Ongoing·Smiths Medical ASD Inc.·April 24, 2024