18 results
·
32ms
·
Sources: EU EUDAMED, US FDA
Filters
Regulation: Us FDA
×
OPTETRAK TOTAL KNEE SYSTEM - MOLDED METAL-BACK TIBIAL COMPONENT
FDA 510(k)
FDA Class 2
·Orthopedic
OPTETRAK Comprehensive Knee System, labeled as the following: a. OPTETRAK All-polyethylene CR Tibial Components, with Product Line Numbers: 200-11-XX, 200-12-XX, 200-13-XX, 200-14-XX, 200-15-XX, 200-16-XX; b. OPTETRAK All-polyethylene PS Tibial Components, with Product Line Numbers: 204-11-XX, 204-12-XX, 204-13-XX, 204-14-XX, 204-15-XX, 204-16-XX; c. OPTETRAK HI-FLEX PS Polyethylene Tibial Inserts, with Product Line Numbers: 244-20-XX, 244-21-XX, 244-22-XX, 244-23-XX, 244-24-XX, 244-25-XX; d. OPTETRAK CR Tibial Inserts, with Product Line Numbers: 200-21-XX, 200-22-XX, 200-23-XX, 200-24-XX, 200-25-XX, 200-26-XX, 200-50-XX, 200-51-XX; e. OPTETRAK CR Tibial Slope + Insert, with Product Line Numbers: 200-56-XX, 200-57-XX, 200-61-XX, 200-62-XX, 200-63-XX, 200-64-XX, 200-65-XX; f. OPTETRAK CR Tibial Slope ++ Insert, with Product Line Numbers: 200-57-XX, 200-71-XX, 200-72-XX, 200-73-XX, 200-74-XX, 200-75-XX; g. OPTETRAK PS Tibial Inserts, with Product Line Numbers: 204-21-XX, 204-22-XX 204-23-XX, 204-24-XX, 204-25-XX, 204-26-XX, 204-50-XX, 204-51-XX; h. OPTETRAK "MOMB" Non-Mod Molded Insert, with Product Line Numbers: 204-91-XX, 204-92-XX, 204-93-XX, 204-94-XX, 204-95-XX; i. OPTETRAK CC Tibial Insert, with Product Line Numbers: 208-21-XX, 208-22-XX, 208-23-XX, 208-24-XX, 208-25-XX, 208-51-XX; j. OPTETRAK B-Series PS Tibial Insert, with Product Line Numbers: 224-21-XX, 224-22-XX, 224-23-XX, 224-24-XX. Affected 510(k) numbers include: K932690, K933494, K932776, K011976, K082022, K933610, K030686, K954208, K010434, K033883. NOTE: Information reflects Exactech recall expansion initiated on 02/07/2022.
FDA Recall
Open, Classified
·Exactech, Inc.·Product code JWH·August 30, 2021
OPTETRAK Comprehensive Knee System, labeled as the following: a. OPTETRAK All-polyethylene CR Tibial Components, with Product Line Numbers: 200-11-XX, 200-12-XX, 200-13-XX, 200-14-XX, 200-15-XX, 200-16-XX; b. OPTETRAK All-polyethylene PS Tibial Components, with Product Line Numbers: 204-11-XX, 204-12-XX, 204-13-XX, 204-14-XX, 204-15-XX, 204-16-XX; c. OPTETRAK HI-FLEX PS Polyethylene Tibial Inserts, with Product Line Numbers: 244-20-XX, 244-21-XX, 244-22-XX, 244-23-XX, 244-24-XX, 244-25-XX; d. OPTETRAK CR Tibial Inserts, with Product Line Numbers: 200-21-XX, 200-22-XX, 200-23-XX, 200-24-XX, 200-25-XX, 200-26-XX, 200-50-XX, 200-51-XX; e. OPTETRAK CR Tibial Slope + Insert, with Product Line Numbers: 200-56-XX, 200-57-XX, 200-61-XX, 200-62-XX, 200-63-XX, 200-64-XX, 200-65-XX; f. OPTETRAK CR Tibial Slope ++ Insert, with Product Line Numbers: 200-57-XX, 200-71-XX, 200-72-XX, 200-73-XX, 200-74-XX, 200-75-XX; g. OPTETRAK PS Tibial Inserts, with Product Line Numbers: 204-21-XX, 204-22-XX 204-23-XX, 204-24-XX, 204-25-XX, 204-26-XX, 204-50-XX, 204-51-XX; h. OPTETRAK "MOMB" Non-Mod Molded Insert, with Product Line Numbers: 204-91-XX, 204-92-XX, 204-93-XX, 204-94-XX, 204-95-XX; i. OPTETRAK CC Tibial Insert, with Product Line Numbers: 208-21-XX, 208-22-XX, 208-23-XX, 208-24-XX, 208-25-XX, 208-51-XX; j. OPTETRAK B-Series PS Tibial Insert, with Product Line Numbers: 224-21-XX, 224-22-XX, 224-23-XX, 224-24-XX. Affected 510(k) numbers include: K932690, K933494, K932776, K011976, K082022, K933610, K030686, K954208, K010434, K033883. NOTE: Information reflects Exactech recall expansion initiated on 02/07/2022.
FDA Enforcement
Class II
·Ongoing·Exactech, Inc.·October 13, 2021
KROM-ALGINATE AND ALGINATE PLUS
FDA 510(k)
FDA Class 2
·Dental
HARDYDISK TICARCILLIN/CLAVULANIC ACID, 85MCG
FDA 510(k)
FDA Class 2
·Microbiology
TRIAGE CARDIAC TRIPLE MARKER PANEL
FDA Adverse Event
Malfunction
·QUIDEL CARDIOVASCULAR INC.·Product code MMI·October 12, 2018
TRIAGE CARDIAC HS PANEL
FDA Adverse Event
Malfunction
·QUIDEL CARDIOVASCULAR INC.·Product code MMI·October 22, 2019
TRIAGE CARDIAC TRIPLE MARKER PANEL
FDA Adverse Event
Malfunction
·QUIDEL CARDIOVASCULAR, INC.·Product code MMI·May 18, 2018
TRIAGE CARDIAC PANEL KIT
FDA Adverse Event
Malfunction
·QUIDEL CARDIOVASCULAR, INC.·Product code JHX·April 18, 2018
TRIAGE CARDIAC HS PANEL
FDA Adverse Event
Malfunction
·QUIDEL CARDIOVASCULAR INC.·Product code MMI·October 21, 2019
TRIAGE CARDIAC TRIPLE MARKER PANEL
FDA Adverse Event
Malfunction
·ALERE SAN DIEGO, INC.·Product code MMI·October 5, 2017
HOMECHOICE
FDA Adverse Event
Malfunction
·BAXTER HEALTHCARE - LARGO·Product code FKX·April 2, 2013
5 FR DL POWERPICC UPFT WITH MI AND TLS
FDA Adverse Event
Injury
·C. R. BARD INC. (BASD)·Product code LJS·March 18, 2011
CELL-DYN WBC REAGENT A
FDA Adverse Event
Malfunction
·ABBOTT DIAGNOSTICS DIVISION/CELLDYN·Product code GKZ·April 15, 2008
TRIAGE CARDIAC TRIPLE MARKER PANEL
FDA Adverse Event
Malfunction
·QUIDEL CARDIOVASCULAR INC.·Product code MMI·November 1, 2018
TI CERVICAL SPINE LOCKING PLATE 45MM (37MM)
FDA Adverse Event
Injury
·SYNTHES MONUMENT·Product code KWQ·September 9, 2015
TRIAGE CARDIAC TRIPLE MARKER PANEL
FDA Adverse Event
Injury
·ALERE SAN DIEGO, INC.·Product code MMI·May 17, 2017
Stryker MA204 Bed Model (FL25E) Beds are intended for medical purposes in both general patient care as well as critical care environments. Each uses built-in electric motors and controls which can be operated by the patient, or caregiver, to adjust the height and/or surface contour of the bed.The devices listed above also include movable and latchable side rails which can be lowered or raised to help prevent patient fall and subsequent injury. The Beds include an optional Scale (Models: FL20E, FL25E, FL28C, FL28EX) as well as an optional Bed Exit (1 Zone) or Chaperone
FDA Enforcement
Class II
·Terminated·Stryker Medical Division of Stryker Corporation·July 4, 2012