21 results · 10ms · Sources: EU EUDAMED, US FDA

Get notified when this changes

We'll email you when new records match this search — new devices, new clearances, certificate changes, or withdrawals.

Arsenal Spinal Fixation System, Set Screw, Part No. 47027 Product Usage: The Arsenal Spinal Fixation System is intended for posterior, non-cervical, spinal fixation as an adjunct to fusion for the treatment of degenerative disease, deformity, and trauma indications. The Arsenal System consists of a variety of shapes and sizes of rods, screws, hooks, connectors, and bridges that provide temporary internal fixation and stabilization during bone graft healing and/or fusion mass development. The screws, hooks, connectors, and bridges are manufactured from surgical grade titanium alloy (Ti-6AI-4V ELl). The rods are available in commercially pure titanium, titanium alloy, and cobalt chrome (CP Ti Grade 4, Ti-6AI-4V ELl, and Co-28Cr-6Mo).

FDA Enforcement
Class II ·Terminated·Alphatec Spine, Inc.·June 14, 2017

ACETABULAR FIXATION CUP, (xx)MM, 5 HOLE, Ti-6AI-4V ELI TiN CERAMIC W/PLASMA SPRAY, STERILEEO, Reference Numbers: 01-01-0554 01-01-0556 01-01-0558 01-01-0560 01-01-0562 01-01-0564 01-01-0566

FDA Enforcement
Class II ·Ongoing·Synovo Production·April 17, 2024

Grasper/Retriever, Alligator Jaw 2.4 mm x 5 mm x 230 cm Catalog Number: 7208 Intended use: single use accessory devices used through the working channel of a GI endoscope

FDA Enforcement
Class II ·Completed·Shent USA, Inc.·August 18, 2021

Grasper/Retriever, Alligator Jaw, Rat Tooth 2.4 mm x 8 mm x 230 cm Catalog Number: 7226 Intended use: single use accessory devices used through the working channel of a GI endoscope

FDA Enforcement
Class II ·Completed·Shent USA, Inc.·August 18, 2021

The Reliance 130 and 130L Cart Washer/Disinfector is a high capacity mechanical washer intended for use in the washing, low-level disinfecting, and drying of carts, utensils, beds and other miscellaneous reusable items used in the care of patients at healthcare facilities / Crated for shipping.

FDA Enforcement
Class II ·Terminated·Steris Corporation·August 8, 2012

Arsenal Spinal Fixation System, Set Screw, Part No. 47127 Product Usage: Usage: The Arsenal Spinal Fixation System is intended for posterior, non-cervical, spinal fixation as an adjunct to fusion for the treatment of degenerative disease, deformity, and trauma indications. The Arsenal System consists of a variety of shapes and sizes of rods, screws, hooks, connectors, and bridges that provide temporary internal fixation and stabilization during bone graft healing and/or fusion mass development. The screws, hooks, connectors, and bridges are manufactured from surgical grade titanium alloy (Ti-6AI-4V ELI). The rods are available in commercially pure titanium, titanium alloy, and cobalt chrome (CP Ti Grade 4, Ti-6Al-4V ELI, and Co-28Cr-6Mo).

FDA Enforcement
Class II ·Terminated·Alphatec Spine, Inc.·November 23, 2016

Femoral Resurfacing Cup - (xx)MM, Ti-6AI-4V ELI, TiN CERAMIC W/ PLASMA SPRAY, STERILEEO, Reference Numbers: 01-03-0042 01-03-0044 01-03-0045 01-03-0047 01-03-0049 01-03-0051 01-03-0052

FDA Enforcement
Class II ·Ongoing·Synovo Production·April 17, 2024

Orca Single Use Air/Water and Suction Valves, Material Number (UPN) SUV-617-50; The Orca Air/Water Valve is intended to be used to control the air/water function on an endoscope during a GI (gastrointestinal) endoscopic procedure.

FDA Enforcement
Class II ·Ongoing·Boston Scientific Corporation·June 17, 2026

PRN 50-M+, GE part number 2062759-001, manufacturer part number 600-23310-01 Product Usage: The PRN 50M+ Paper Chart Recorder thermally records patient data on a paper strip. This device is intended for use under direct supervision of a licensed health care practitioner. This device is not intended for home use.

FDA Enforcement
Class II ·Terminated·Gsi Group Inc·March 2, 2016

Trinica Anterior Lumbar Plate (ALP) system, part 07.01058.001. Non Sterile, Rx only. The Trinica Anterior Lumbar Plate System is a temporary supplemental fixation device consisting of a variety of shapes and sizes of plates and screws. The Trinica Anterior Lumbar Plate System is used as an implant for the correction and stabilization of the spine. This system provides temporary stabilization and augments the development of a solid spinal fusion. Additionally, this system provides the surgeon with the ability to supplement an interbody device with anterior plate fixation. The Trinica Anterior Lumbar Plate System components can be locked into a variety of configurations and each construct may be customized to individual cases. The plates are low profile and anatomically designed to provide optimal fit from either anterior or anterior-lateral approach. This system also features anti-migration locking caps to help secure the fixation screws. All Trinica Anterior Lumbar Plate System implant components are made from titanium alloy (Ti-6AI-4V). The Trinica Anterior Lumbar Plate System is indicated for use via the lateral or anterolateral surgical approach above the bifurcation of the great vessels or via the anterior surgical approach, below the bifurcation of the great vessels. This system is indicated in the treatment of lumbar or lumbosacral (L1-SI) spine instability as a result of fracture (including dislocation and subluxation), tumor, degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), pseudoarthrosis, spondylolisthesis, scoliosis, lordotic deformities of the spine, spinal stenosis, or a failed previous fusion.

FDA Enforcement
Class II ·Terminated·Zimmer, Inc.·November 27, 2013

Medtronic Temporary Pacemaker, Model 5348. Single Chamber External Pulse Generator (EPG) Temporary Pacemaker (AAI/VVI). Used in conjunction with a cardiac pacing lead system for temporary atrial or ventricular pacing in a clinical environment. The device is typically connected to temporary transvenous, epicardial or myocardial pacing leads, in a bipolar configuration, using a patient cable (Medtronic Model 5433A or 5433V) or a surgical cable (Medtronic Model 5832 or 5832S).

FDA Enforcement
Class II ·Terminated·Medtronic Inc. Cardiac Rhythm Disease Management·June 4, 2014

On Site Gas Systems POGS 33C Portable Oxygen Generation System

FDA Enforcement
Class II ·Terminated·On Site Gas Systems Inc.·January 15, 2014

MEDICYCL-E- Lite Portable Oxygen System An integrated portable oxygen delivery system intended to provide supplemental oxygen to adults. The device is MRI safe, MRI-compatible, and intended for use during MR Imaging for MRI systems up to 3.0 T. For emergency use only when administered by properly trained personnel for oxygen deficiency and resuscitation. For all other medical applications, Rx only.

FDA Enforcement
Class II ·Terminated·Linde Gas North America Llc·June 26, 2013

Halyard Closed Suction System for Adults, Multi-Access¿Port¿Closed¿Suction¿System¿for¿Adults. Used to aspirate liquids or semisolids from a patient's upper airway. a. HALYARD* MULTI-PORT, DSY, ENDO 10FR; b. HALYARD* MULTI-PORT, DSY, ENDO 12FR; c. HALYARD* MULTI-PORT, DSY, ENDO, MDI 12FR; d. HALYARD* MULTI-PORT, DSY, ENDO 14FR; e. HALYARD* MULTI-PORT, DSY, TRACH 14FR; f. HALYARD* MULTI-PORT, DSY, TRACH, WP 14FR; g. HALYARD* MULTI-PORT, DSY, ENDO, MDI 14FR; h. HALYARD* MULTI-PORT, DSY, ENDO, WP 14FR; i. HALYARD* MULTI-PORT, DSY, ENDO, WP 14FR; j. HALYARD* MULTI-PORT, DSY, ENDO, MDI 14FR; k. HALYARD* MULTI-PORT, DSY, ENDO, MDI 16FR;

FDA Enforcement
Class II ·Terminated·Halyard Health, Inc·April 25, 2018

Aurora Series, Aurora 7 lighthead; Models: LED7 (including TV models). The Aurora Series is intended to illuminate the surgical field and ensure visibility of the surgical site.

FDA Enforcement
Class II ·Ongoing·DKK Dai-Ichi Shomei Co., Ltd.·August 21, 2024

Aurora 2 Series, Aurora 7 lighthead; Models: AUR7 (including TV models). The Aurora Series is intended to illuminate the surgical field and ensure visibility of the surgical site.

FDA Enforcement
Class II ·Ongoing·DKK Dai-Ichi Shomei Co., Ltd.·August 21, 2024

Aurora 3 Series, Aurora 7 lighthead; Models: AUT7 (including TV models). The Aurora Series is intended to illuminate the surgical field and ensure visibility of the surgical site.

FDA Enforcement
Class II ·Ongoing·DKK Dai-Ichi Shomei Co., Ltd.·August 21, 2024

Aurora 4 Series, Aurora 7 lighthead; Models: AUA7 (including TV models). The Aurora Series is intended to illuminate the surgical field and ensure visibility of the surgical site.

FDA Enforcement
Class II ·Ongoing·DKK Dai-Ichi Shomei Co., Ltd.·August 21, 2024

LFS Flat screen arm system with surgical lamp for Models Aurora series, Aurora 2 series, Aurora 3 series, Aurora 4 series, Aurora Astro series, Stellar XL, and Stellar series, LFS Flat Screen Arm System Model Numbers LFSST2323, LFSLFSST29TV23, LFSST29TV23, LFSST23TV, LFSST23, LFSST2323TV, LFSLFSST2323, LDFSLFSLED7TV5, LDFSLFSLED7TV55, LFSLED55, LFSLFSST23, LFSST2923TV, LFSST29TV, LFSST29, LFSST19WC, LFSST2923, LFSLFSST-1, LFSST292323, LFSST1919WC, LFS ST2319WC

FDA Enforcement
Class II ·Ongoing·DKK Dai-Ichi Shomei Co., Ltd.·October 11, 2023

LFS Flat screen support arm systems without surgical lamp for models Aurora series, Aurora 2 series, Aurora 3 series, Aurora 4 series, Aurora Astro series, Stellar XL, and Stellar series, LFS Flat Screen Support Arm Model Numbers

FDA Enforcement
Class II ·Ongoing·DKK Dai-Ichi Shomei Co., Ltd.·October 11, 2023