62 results
·
8ms
·
Sources: EU EUDAMED, US FDA
Xcela PICC with PASV Valve Technology/Kit 5 F-55cm; (Maximum Flow Rate 3.5 mL/Sec)-indicated for short or long-term peripheral access to the central venous system for intravenous therapy, including but not limited to, the administration of fluids, medications, and nutrients; the sampling of blood; and for power injection of contrast media. Catalog Number: 60M701995
FDA Enforcement
Class II
·Terminated·Angiodynamics Inc. (Navilyst Medical Inc.)·October 6, 2021
iLab Ultrasound Imaging System; iLab 3.0 (Polaris 1.0) software. Used for ultrasound examinations of intravascular pathology.
FDA Enforcement
Class II
·Terminated·Boston Scientific Corporation·April 30, 2014
Zeppessis' reprocessed single-use manifolds (filters) for the Stryker Neptune 1 and Neptune 2 Waste Management Systems: The Neptune Waste management system is intended to be used in the Operating Room, Surgical Centers and Doctor's Offices to collect and dispose of surgical fluid waste as well as collect smoke generated from electrocautory or laser devices. ***The single-port manifold for the Stryker Neptune 1 (part # 700-015-000) can be used with the: Neptune 1 Gold Rover or the Neptune Bronze Rover as an accessory to Class 2 Air-handling apparatus for a surgical operating room (Sec. 878.5070); or with the Neptune 1 Silver Rover as an accessory to Class 2 Powered suction pump. ***four-port manifold for the Stryker Neptune 1 (part # 700-020-000) can be used with the: Neptune 1 Gold Rover or the Neptune Bronze Rover as an accessory to Class 2 Air-handling apparatus for a surgical operating room (Sec. 878.5070); or with the Neptune 1 Silver Rover as an accessory to Class 2 Powered suction pump. ***single-port manifold for the Stryker Neptune 2 (part # 702-025-000) can be used with the Neptune 2 Rover Ultra as an accessory to Class 2 Powered suction pump. ***four-port manifold for the Stryker Neptune 2 (part # 702-020-000) can be used with the Neptune 2 Rover Ultra as an accessory to Class 2 Powered suction pump.
FDA Enforcement
Class II
·Terminated·Zeppessis Reprocessing, LLC·September 25, 2013
BD PosiFlush SF Saline Flush Syringe 10 mL used in POWERWAND XL 5Fr 8cm Quick Kit. REF/UDI / 94114/10859821006220 - Product Usage: is used to gain access to the vascular system to sample blood and administer fluids intravenously. It may be used for power injection of contrast media up to a rate of 8 ml/sec and at a maximum of 325 psi fluid pressure.
FDA Enforcement
Class II
·Terminated·Access Scientific LLC·May 20, 2020
BD PosiFlush SF Saline Flush Syringe 10 mL used in POWERWAND XL 5Fr 8cm Max Barrier Kit. REF/UDI / 94116/10859821006237 - Product Usage: is used to gain access to the vascular system to sample blood and administer fluids intravenously. It may be used for power injection of contrast media up to a rate of 8 ml/sec and at a maximum of 325 psi fluid pressure.
FDA Enforcement
Class II
·Terminated·Access Scientific LLC·May 20, 2020
BD PosiFlush SF Saline Flush Syringe 10 mL used in POWERWAND XL 5Fr 10cm Quick Kit. REF/UDI / 94115/10859821006251 - Product Usage: is used to gain access to the vascular system to sample blood and administer fluids intravenously. It may be used for power injection of contrast media up to a rate of 8 ml/sec and at a maximum of 325 psi fluid pressure.
FDA Enforcement
Class II
·Terminated·Access Scientific LLC·May 20, 2020
Single Basin Kits, Sterile-.Kits containing the Devon Light Glove Catalog Number/Description: 573509 7696-GSL-VL SINGLE BASIN KIT 573558 7665-CPB SINGLE BASIN KIT 573561 7696-KSC SINGLE BASIN KIT 31145645 7608 Single Basin KIT 31153060 7697-T4 Single Basin Kit 50000568 7605-SEC Single Basin Kit 50000599 7694-ADA Single Basin Kit 50007698 7698-T4 Single Basin Kit 50007699 7699-T4 Single Basin Kit
FDA Enforcement
Class II
·Terminated·Covidien LLC·July 29, 2015
BD PosiFlush SF Saline Flush Syringe 10 mL used in POWERWAND XL 4Fr 10cm Extended Dwell Catheter. REF/UDI / 94108/00859821006773 - Product Usage: is used to gain access to the vascular system to sample blood and administer fluids intravenously. It may be used for power injection of contrast media up to a rate of 8 ml/sec and at a maximum of 325 psi fluid pressure.
FDA Enforcement
Class II
·Terminated·Access Scientific LLC·May 20, 2020
BD PosiFlush SF Saline Flush Syringe 10 mL used in POWERWAND XL 3Fr 6cm Pediatric Kit. REF/UDI / 94124/10859821006480 - Product Usage: is used to gain access to the vascular system to sample blood and administer fluids intravenously. It may be used for power injection of contrast media up to a rate of 8 ml/sec and at a maximum of 325 psi fluid pressure.
FDA Enforcement
Class II
·Terminated·Access Scientific LLC·May 20, 2020
BD PosiFlush SF Saline Flush Syringe 10 mL used in POWERWAND XL 3Fr 6cm Quick Kit. REF/UDI / 94123/10859821006473 - Product Usage: is used to gain access to the vascular system to sample blood and administer fluids intravenously. It may be used for power injection of contrast media up to a rate of 8 ml/sec and at a maximum of 325 psi fluid pressure.
FDA Enforcement
Class II
·Terminated·Access Scientific LLC·May 20, 2020
BD PosiFlush SF Saline Flush Syringe 10 mL used in POWERWAND XL 4Fr 8cm Max Barrier Kit. REF/UDI / 94106/10859821006176 - Product Usage: is used to gain access to the vascular system to sample blood and administer fluids intravenously. It may be used for power injection of contrast media up to a rate of 8 ml/sec and at a maximum of 325 psi fluid pressure.
FDA Enforcement
Class II
·Terminated·Access Scientific LLC·May 20, 2020
BD PosiFlush SF Saline Flush Syringe 10 mL used in POWERWAND"XL Alternate Site Kit, 4Fr . REF/UDI 80701/10859821006213 - Product Usage: is used to gain access to the vascular system to sample blood and administer fluids intravenously. It may be used for power injection of contrast media up to a rate of 8 ml/sec and at a maximum of 325 psi fluid pressure.
FDA Enforcement
Class II
·Terminated·Access Scientific LLC·May 20, 2020
BD PosiFlush SF Saline Flush Syringe 10 mL used in POWERWAND XL 4Fr 10cm Max Barrier Kit. REF/UDI / 94107/10859821006206 - Product Usage: is used to gain access to the vascular system to sample blood and administer fluids intravenously. It may be used for power injection of contrast media up to a rate of 8 ml/sec and at a maximum of 325 psi fluid pressure.
FDA Enforcement
Class II
·Terminated·Access Scientific LLC·May 20, 2020
BD PosiFlush SF Saline Flush Syringe 10 mL used in POWERWAND XL 4Fr 10cm Quick Kit. REF/UDI / 94105/10859821006190 - Product Usage: is used to gain access to the vascular system to sample blood and administer fluids intravenously. It may be used for power injection of contrast media up to a rate of 8 ml/sec and at a maximum of 325 psi fluid pressure.
FDA Enforcement
Class II
·Terminated·Access Scientific LLC·May 20, 2020
BD PosiFlush SF Saline Flush Syringe 10 mL used in POWERWAND" ED Quick Kit 3FR 6cm. REF/UDI 72627/ 00859821006674 - Product Usage: is used to gain access to the vascular system to sample blood and administer fluids intravenously. It may be used for power injection of contrast media up to a rate of 8 ml/sec and at a maximum of 325 psi fluid pressure.
FDA Enforcement
Class II
·Terminated·Access Scientific LLC·May 20, 2020
BD PosiFlush SF Saline Flush Syringe 10 mL used in POWERWAND XL 4Fr 8cm Quick Kit. REF/UDI / 94104/10859821006169 - Product Usage: is used to gain access to the vascular system to sample blood and administer fluids intravenously. It may be used for power injection of contrast media up to a rate of 8 ml/sec and at a maximum of 325 psi fluid pressure.
FDA Enforcement
Class II
·Terminated·Access Scientific LLC·May 20, 2020
Master Drug Library Software version 8.0, Product Code 35723V080, to be used with SIGMA Spectrum Infusion System (Pump) version 8.0, Product Code 35700BAX2 The SIGMA Spectrum Infusion Pump with Master Drug Library (MDL) is intended to be used for the controlled administration of fluids.
FDA Enforcement
Class II
·Terminated·Baxter Healthcare Corp·April 22, 2015
Pentax Video Colonoscope is intended to be used with a PENTAX video processor (including light source), documentation equipment, Monitor, EndoTherapy Device such as a Biopsy Forceps, and other ancillary equipment for endoscopy and endoscopic surgery within the lower digestive tract including the anus, rectum, sigmoid colon, colon and ileocecal valve.
FDA Enforcement
Class II
·Terminated·Pentax of America Inc·November 30, 2016
Colonoscope Intended to provide optical visualization of and therapeutic access to the Lower Gastrointestinal Tract. This anatomy includes, but is not restricted to, the organs, tissues and subsystems: Large Bowel to the Cecum. The instrument is introduced via the rectum when indications consistent with the need for procedure are observed in adult and pediatric patient populations.
FDA Enforcement
Class II
·Terminated·Pentax Medical Company·July 6, 2016
Intraocular Lens (IOL), Part No. EC-3 PAL, Diopter: 17.5, 18.0, 18.5, 19.0, 19.5, 21.5, 23.5, 9.0, 22.5, 23.0, 21.0, 24.0. The device is indicated for primary implantation in the capsular bag of the eye for the visual correction of aphakia in adult patients in whom a cataractous lens has been removed. Aaren Scientifics EC-3 IOLs are intended for primary implantation in the capsular bag of the eye for the visual correction of aphakia in adult patients in whom a cataractous lens has been removed by phacoemulsification.
FDA Enforcement
Class II
·Terminated·Aaren Scientific, Incorporated·April 1, 2015