7 results · 6ms · Sources: EU EUDAMED, US FDA

Get notified when this changes

We'll email you when new records match this search — new devices, new clearances, certificate changes, or withdrawals.

iVue and iVue 500 (now called iScan) OCT systems with software version 2016.0.0.127 (USA only) and 2016.1.0.127 (out of US) Opthalmic: iVue is a non-contact, high resolution tomographic imaging device. It is intended for in vivo imaging, axial cross-sectional and three-dimensional imaging and measurement of anterior and posterior ocular structures, including retina, retinal nerve fiber layer, ganglion cell complex (GCC), optic disc, cornea, and anterior chamber the eye.

FDA Enforcement
Class II ·Terminated·Optovue, Inc.·April 27, 2016

iVue with Normative Database, Device Listing Number D185549. Product Usage: The iVue (K121739) is a non-contact, high resolution tomographic imaging device. It is intended for in vivo imaging, axial cross-sectional, and three dimensional imaging and measurement of anterior and posterior ocular structures, including retina, retinal nerve fiber layer, ganglion cell complex (GCC), optic disc, cornea, and anterior chamber of the eye. The iVue with Normative Database is a quantitative tool for the comparison of retina, retinal nerve fiber layer, ganglion cell complex, and optic disc measurements to a database of known normal subjects. The iVue with Normative Database is indicated for use as a device to aid in the diagnosis, documentation, and management of ocular health and diseases in the adult population.

FDA Enforcement
Class II ·Terminated·Optovue, Inc.·September 6, 2017

Reference materials "RETINAL OCT Analysis and Interpretation Method" shipped with iVue System (K091404) and the "Retina Poster" shipped with iVue System (K091404) and RTVue Systems (K101505); Models: iVue-100, RTVue-100; The physical Product is manufactured and distributed by Optovue, Inc. Fremont, CA The product is an optical coherence tomography system indicated for the in vivo imaging and measurement of the retina, retinal nerve fiber layer, optic disk, and for cornea and anterior eye scans as an aid in the diagnosis and management of retinal disease.

FDA Enforcement
Class II ·Terminated·Optovue Inc.·October 31, 2012

iVue 500 with iScan, D216606. Product non-contact, high resolution tomographic imaging device. It is intended for in vivo imaging, axial cross-sectional and three-dimensional imaging and measurement of anterior and posterior ocular structures, including retina, retinal nerve fiber layer, ganglion cell complex (GCC), optic disc, cornea, and anterior chamber of the eye. The iVue 500 with normative database is a quantitative tool for the comparison of retina, retinal nerve fiber layer, ganglion cell complex, and optic disc measurements to a database of known normal subjects. The iVue 500 with normative database is indicated for use as a device to aid in the diagnosis, documentation, and management of ocular health and diseases in the adult population.

FDA Enforcement
Class II ·Terminated·Optovue, Inc.·September 6, 2017

iFusion, Device Listing Number D203271. Product Usage: The iCam is a non-contact, high resolution digital imaging device which is suitable for photographing, displaying and storing images of the retina and external areas of the eye to be evaluated under non-mydriatic conditions. The iCam takes digital images of the posterior and external structures of the eye without the use of a mydriatic agent and is intended for use as an aid to clinicians in the evaluation, diagnosis and documentation of ocular health. iCam provides images only and does not provide any diagnostic, pathological analysis or classification of ocular health or disease. AND iVue with Normative Database (K121739) - The iVue is a noncontact, high resolution optical coherence tomography system intended for in vivo imaging, axial cross-sectional, three-dimensional imaging and measurement of anterior and posterior. ocular structures, including retina, retinal nerve fiber layer, ganglion cell complex (GCC), optic disc, cornea, and anterior chamber of the eye. The iVue with Normative Database is a quantitative tool for comparison of retina, retinal nerve fiber layer, ganglion cell complex, and optic disc measurements to a database of known normal subjects.

FDA Enforcement
Class II ·Terminated·Optovue, Inc.·September 6, 2017

Digital Lightbox, BrainLAB system, image processing, radiological Product Usage: The Patient Data Manager is a system intended for the display of medical images. The software can transfer images to and from picture archiving and communication systems (PACS), file servers, or removable storage media. It includes functions for image manipulation, basic measurements and 3D visualization (reconstructions and volume rendering). Features for navigation planning include multi-modality image fusion as well as object and trajectory creation. It is not intended for primary image diagnosis or the review of mammographic images.

FDA Enforcement
Class II ·Terminated·Brainlab AG·November 11, 2015

2.3mm Turbo-Power OTW, Manual, Model No 423-050 Product Usage The Turbo-Power System (Laser Atherectomy Catheter) is a laser atherectomy device designed for use with the CVX-300" Excimer Laser System. The Turbo-Power Laser Atherectomy Catheter is a sterile, single use, prescription only device used for peripheral atherectomy. Turbo-Power is used exclusively with SPNC s CVX 300" Excimer Laser System and is a Type CF device, Defibrillation proof. Turbo-Power is a laser atherectomy catheter designed for treatment of de novo or restenotic lesions in native infrainguinal arteries and for the treatment of femoropopliteal artery in-stent restenosis (ISR) in bare nitinol stents, with adjunctive Percutaneous Transluminal Angioplasty (PTA). Turbo-Power is used to directionally ablate infrainguinal concentric and eccentric lesions in vessels that are 3.5 mm or greater in diameter. The device is comprised of three parts: the working length of the catheter shaft (also the applied part), the motor drive unit (MDU), and the proximal laser shaft which connects the catheter fiber optics to the CVX-300" Excimer Laser System.

FDA Enforcement
Class II ·Terminated·Spectranetics Corp.·February 17, 2016