LATITUDE NXT Remote Patient Management System, LATITUDE NXT System Server Software Model 6460.
FDA Enforcement
Class II
·Ongoing·Boston Scientific Corporation·March 15, 2023
HAMILTON-C6, REF: 160021
FDA Enforcement
Class II
·Ongoing·Hamilton Medical AG·May 3, 2023
Luminos Agile Max, Luminos dRF Max, and LUMINOS Lotus Max
FDA Enforcement
Class II
·Ongoing·Siemens Medical Solutions USA, Inc·January 25, 2023
BD Nexiva, 20 GA 1.00 IN (1.1 X 25 mm), 3660 ml/hr. 61ml/min; Closed IV Catheter System- Dual port -61 mL/min (3660 mL/hr)-0.5mL, REF 383536; BD Q-Style Luer Access Split Septum BD Vialon Material; BD Instaflash Needle Technology; Rx Only, Sterile EO. BD Nexiva closed IV catheter systems are over-the-needle, intravascular catheters. These devices have a radiopaque BD Vialon" catheter, needle, needle shield, septum, stabilization platform, integrated extension tubing, clamp, dual port adapter, vent plug and pre-attached BD Q-Syte Luer Access Split Septum. The needle and catheter are protected by a needle cover. A BD Q-Syte device or an end cap with protective cover is provided in the unit package. The closed system is designed to keep blood contained within the device throughout the insertion process. The septum is designed to wipe visible blood from the needle surface as the needle is withdrawn from the catheter, further reducing the risk of blood exposure. The needle tip is passively protected when the needle is removed, reducing the risk of accidental needlestick injury. These devices have BD Instaflash" Needle Technology, allowing for immediate visualization of blood along the catheter. Continuous blood return is seen in the extension tubing. The vent plug prevents blood leakage from the extension tubing during insertion. Both the stabilization platform and dual port adapter are color coded to indicate catheter gauge size (24GA (0.7 mm)=Yellow, 22GA (0.9 mm)=Blue, 20GA (1.1 mm)=Pink, 18GA (1.3 mm)=Green). BD Nexiva closed IV catheter systems are intended to be inserted into a patient s vascular system for short term use to sample blood, monitor blood pressure, or administer fluids. These catheters may be used for any patient population with consideration given to adequacy of vascular anatomy, procedure being performed, fluids being infused, and duration of therapy. The 22-18GA (0.9-1.3 mm) devices are suitable for use with power injectors set to a maximum pressure of 300 psi (2068 kPa) when access ports not suitable for use with power injectors are removed.
FDA Enforcement
Class II
·Ongoing·Becton Dickinson Infusion Therapy Systems Inc.·December 1, 2021
Prestige Coil System REFs/UDI-DI codes: PRES0153CXPPLT 00810068567311 PRES1045CPKPLT 00810068567663 PRES1245CPKPLT 00810068567694 PRES1445CPKPLT 00810068567724 PRES0103CXPPLT 00810068567304 PRES2512CXPPLT 00810068567397 PRES0258CXPPLT 00810068567380 PRES0212CXPPLT 00810068567373 PRES0204CXPPLT 00810068567342 PRES0206CXPPLT 00810068567359 PRES0208CXPPLT 00810068567366 PRES3520CXPPLT 00810068567441 PRES3530CXPPLT 00810068567458 PRES0310CXPPLT 00810068567403 PRES0320CXPPLT 00810068567410 PRES0420CPKPLT 00810068567489 PRES0517CPKPLT 00810068567519 PRES0540CPKPLT 00810068568028 PRES0620CPKPLT 00810068567557 PRES0635CPKPLT 00810068567564 PRES0650CPKPLT 00810068567571 PRES0720CPKPLT 00810068567588 PRES0735CPKPLT 00810068567595 PRES0750CPKPLT 00810068567601 PRES0830CPKPLT 00810068567618 PRES0845CPKPLT 00810068567625 PRES0153HXPPL 00818053027147 PRES0204HXPPL 00818053029943 PRES0204CXPPL 00818053027321 PRES0208HXPPL 00818053029981 PRES0315HXPPL 00818053027178 PRES0307CXPPL 00818053027376 PRES0420HPKPL 00818053027185 PRES0440HPKPL 00810068567830 PRES0520HPKPL 00818053027192 PRES0540HPKPL 00810068567847 PRES0650HPKPL 00810068567854 PRES0720HPKPL 00818053027215 PRES0750HPKPL 00810068567861 PRES0830HPKPL 00818053027222 The Prestige Coil System consists of an implantable embolization coil comprised of a platinum-tungsten alloy attached to a proximal stainless steel hypotube and distal body coil delivery pusher with a radiopaque distal positioning marker and a proximal fluorosafe marker. The Optima Coil delivery pusher is 185cm in length. It is designed for use with the XCEL Detachment Controller. The XCEL Detachment Controller comes pre-loaded with batteries and is a sterile, handheld, single patient-use device which should not be reused, re-sterilized, opened or tampered with. The Optima Coil achieves detachment by an internal heater element, which is powered by the XCEL Detachment Controller. The Optima Coil System and XCEL Detachment Controller(s) are sold separately.
FDA Enforcement
Class II
·Ongoing·BALT USA, LLC·June 25, 2025
Optima Coil System REFs/UDI-DI codes: OPTI0156BLK 00810068568875 OPTI0158BLK 00810068568882 OPTI0103BLK 00810068568851 OPTI0258BLK 00810068568929 OPTI0212BLK 00810068568912 OPTI0206BLK 00810068568905 OPTI0310BLK 00810068568943 OPTI0320BLK 00810068568950 OPTI0151HSS10 00818053026614 OPTI0152HSS10 00840303701002 OPTI0153HSS10 00840303701019 OPTI0154CSS10 00818053025761 OPTI0154HSS10 00840303701026 OPTI1027CST10 00840303700142 OPTI1030HST10 00818053027086 OPTI1034COM18 00818053026461 OPTI1137COM18 00818053026478 OPTI1550COM18 00818053026515 OPTI0101CSS10 00818053025709 OPTI0101HSS10 00840303700951 OPTI0102CSS10 00818053025716 OPTI0102HSS10 00840303700968 OPTI0103HSS10 00818053026591 OPTI0103CSS10 00818053025723 OPTI0104HSS10 00818053026607 OPTI0254CSS10 00840303700548 OPTI0255CSF10 00840303700203 OPTI0256CSS10 00818053025853 OPTI0256HSS10 00818053026737 OPTI0202HSS10 00840303701040 OPTI0203HSS10 00840303701057 OPTI0203CSS10 00818053025785 OPTI0204CSS10 00840303700494 OPTI0204HSS10 00840303701064 OPTI0206CSF10 00818053026027 OPTI0206CSS10 00818053025808 OPTI0208CSF10 00818053026034 OPTI0208HSS10 00840303701088 OPTI0208CSS10 00840303700517 OPTI0358CSS10 00818053025921 OPTI0310HSS10 00840303701156 OPTI0310CSS10 00818053025907 OPTI0310HSF10 00840303700814 OPTI0310CSF10 00840303700234 OPTI0304HSS10 00840303701125 OPTI0304HSF10 00840303700784 OPTI0304CSS10 00818053025877 OPTI0306HSS10 00840303701132 OPTI0308HSS10 00840303701149 OPTI0308CSF10 00818053026065 OPTI0308CSS10 00840303700593 OPTI0410CSS10 00840303700654 OPTI0410HSF10 00840303700852 OPTI0413CSF10 00818053026119 OPTI0406HSS10 00840303701163 OPTI0408HSS10 00818053026799 OPTI0413CST10 00840303700036 OPTI0510HSS10 00840303701217 OPTI0510CSS10 00840303700685 OPTI0510HSF10 00840303700890 OPTI0513CSS10 00840303700692 OPTI0517CSF10 00818053026157 OPTI0517CST10 00840303700050 OPTI0508CSS10 00840303700678 OPTI0509CSF10 00818053026140 OPTI0610HSF10 00840303700937 OPTI0611CSF10 00818053026171 OPTI0620CSF10 00840303700357 OPTI0620HST10 00840303700715 OPTI0713CST10 00840303700081 OPTI0713CSF10 00840303700364 OPTI0724CSF10 00818053026218 OPTI0724CST10 00840303700098 OPTI0724COM18 00818053026430 OPTI0827CSF10 00818053026232 OPTI0827CST10 00840303700111 OPTI0923CST10 00818053026379 OPTI0930COM18 00818053026454 OPTI0153HSSMX 00818053025419 OPTI1040CSFMX 00818053025280 OPTI1245CSFMX 00818053025303 OPTI1445CSFMX 00818053025327 OPTI1650CSFMX 00818053025341 OPTI0103CSSMX 00840303701408 OPTI2525CSSMX 00840303701477 OPTI0255CSSMX 00818053025020 OPTI0202CSSMX 00818053024979 OPTI3535CSSMX 00818053025068 OPTI0310CSSMX 00818053025051 OPTI0307CSSMX 00818053025044 OPTI4510CSFMX 00818053025143 OPTI4545CSFMX 00818053025136 OPTI0413CSFMX 00818053025129 OPTI0404CSFMX 00818053025099 OPTI0407CSFMX 00818053025105 OPTI0510CSFMX 00818053025167 OPTI0507CSFMX 00818053025150 OPTI0715CSFMX 00818053025228 OPTI0720CSFMX 00818053025235 OPTI0930CSFMX 00818053025266 The Optima Coil System consists of an implantable embolization coil comprised of a platinum-tungsten alloy attached to a proximal stainless steel hypotube and distal body coil delivery pusher with a radiopaque distal positioning marker and a proximal fluorosafe marker. The Optima Coil delivery pusher is 185cm in length. It is designed for use with the XCEL Detachment Controller. The XCEL Detachment Controller comes pre-loaded with batteries and is a sterile, handheld, single patient-use device which should not be reused, re-sterilized, opened or tampered with. The Optima Coil achieves detachment by an internal heater element, which is powered by the XCEL Detachment Controller. The Optima Coil System and XCEL Detachment Controller(s) are sold separately.
FDA Enforcement
Class II
·Ongoing·BALT USA, LLC·June 25, 2025