Virage OCT Spinal Fixation System. Intended to promote fusion of the Occipital-Cervical-Thoracic spine (Occiput-T3).

FDA Enforcement
Class II ·Terminated·Zimmer Spine, Inc.·March 9, 2016

Zimmer, Virage OCT Spinal Fixation System, Item Number: 07.01738.001, a posterior system intended to achieve an implant and construct of the Occipital-Cervical-Thoracic spine (Occiput-T3). UDI Number 889024328952

FDA Enforcement
Class II ·Terminated·Zimmer Biomet, Inc.·January 20, 2016

Altius M-INI OCT Posterior Spinal Fixation System, Model Number 1200-9216 The AltiusTM OCT and AltiusTM M-INITM OCT Systems when intended to promote fusion of the cervical spine and occipitocervico-thoracic junction (Occiput-T3), these systems are indicated for: DDD (neck pain of discogenic origin with degeneration of the disc as confirmed by patient history and radiographic studies); spondylolisthesis; spinal stenosis; fracture/dislocation; atlantoaxial fracture with instability; occipitocervical dislocation; revision of previous cervical spine surgery; and tumors. The occipital bone screws are limited to occipital fixation only

FDA Enforcement
Class II ·Terminated·Zimmer Biomet Spine, Inc·April 5, 2017

The TM Ardis Interbody System Inserter Stainless Steel, Rubber, Silicone Non Sterile Rx only. The TM Ardis Inserter is intended for delivery of the TM Ardis Implant into the cleared disc space. The implant is secured to the inserter via finger-tightening the knob of the inserter shaft allowing the lateral grasping arms to secure the implant. Once the implant is inserted and its position confirmed radiographically, the inserter is removed from the implant by turning the shaft knob counterclockwise to loosen the lateral grasping arms from the implant.

FDA Enforcement
Class II ·Terminated·Zimmer, Inc.·January 16, 2013

Zyston¿ Transform Implant Kit. Model Number PCR8200-3101. Device labeled sterile.

FDA Enforcement
Class II ·Terminated·Zimmer Biomet Spine, Inc·August 17, 2016

Zyston¿ Transform Instrument Case. Model Number PCR8200-2101. Device labeled sterile.

FDA Enforcement
Class II ·Terminated·Zimmer Biomet Spine, Inc·August 17, 2016

Pathfinder NXT Fixed Percutaneous Rod Holder, Part numbers 3573-2 (straight handle) Stainless Steel / Silicone Rubber, Rx only, non sterile. Product Usage: PathFinder NXT is a minimally invasive pedicle screw system. The PathFinder NXT System consists of various screws and rods intended to provide temporary stabilization following surgery to fuse the spine. The intended use of the Fixed Angled Percutaneous Rod Inserter is to insert a rod percutaneously through the extender sieeves to position into the implanted screw heads for securing with closure tops forming a construct that provides temporary stabilization following MIS or mini-open surgery to fuse the spine.

FDA Enforcement
Class II ·Terminated·Zimmer, Inc.·July 18, 2012

Instinct¿ Java¿ System (IFU reference: 046WAN0000T) . Stabilizes one or more vertebral segments from the thoracic spine to the sacrum during the development of bone tissue.

FDA Enforcement
Class II ·Terminated·Zimmer Spine, Inc.·March 30, 2016

10mm X 12o Solitaire Ti Medium Spacer  Solitaire Anterior Spinal System, Model Number 1400-1230. Product Usage: The SOLITAIRETM SPINAL SYSTEM is designed for use with autograft and is indicated for stand-alone intervertebral body fusion at one level or two contiguous levels in the lumbar spine from L2 to S1 in patients with degenerative disc disease (DDD) with up to Grade 1 spondylolisthesis at the involved level(s). DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies. These patients should be skeletally mature and have had six months of non-operative treatment. Additionally, the SOLITAIRETM ANTERIOR SPINAL SYSTEM is indicated for use in the thoracolumbar spine (i.e., T10 to L5) to replace a diseased vertebral body resected or excised for the treatment of tumors in order to achieve anterior decompression of the spinal cord and neural tissues, and to restore the height of a collapsed vertebral body. The SolitaireTM System is also indicated for treating fractures of the thoracic and lumbar spine. The SolitaireTM System is designed to restore the biomechanical integrity of the anterior, middle and posterior spinal column even in the absence of fusion for a prolonged period.

FDA Enforcement
Class II ·Terminated·Biomet Spine, LLC·April 6, 2016

Pathfinder NXT Fixed Percutaneous Rod Holder, Part numbers 3573-1 (angle handle) , Stainless Steel / Silicone Rubber, Rx only, non sterile. Product Usage: The rod is held by the instrument for inserting and guiding into the screw heads via percutaneous delivery during minimally invasive surgery to fuse the spine. Per the surgical technique (Ll554 Pathfinder NXT Surgical Technique);

FDA Enforcement
Class II ·Terminated·Zimmer, Inc.·July 18, 2012

Trinica Anterior Lumbar Plate (ALP) system, part 07.01058.001. Non Sterile, Rx only. The Trinica Anterior Lumbar Plate System is a temporary supplemental fixation device consisting of a variety of shapes and sizes of plates and screws. The Trinica Anterior Lumbar Plate System is used as an implant for the correction and stabilization of the spine. This system provides temporary stabilization and augments the development of a solid spinal fusion. Additionally, this system provides the surgeon with the ability to supplement an interbody device with anterior plate fixation. The Trinica Anterior Lumbar Plate System components can be locked into a variety of configurations and each construct may be customized to individual cases. The plates are low profile and anatomically designed to provide optimal fit from either anterior or anterior-lateral approach. This system also features anti-migration locking caps to help secure the fixation screws. All Trinica Anterior Lumbar Plate System implant components are made from titanium alloy (Ti-6AI-4V). The Trinica Anterior Lumbar Plate System is indicated for use via the lateral or anterolateral surgical approach above the bifurcation of the great vessels or via the anterior surgical approach, below the bifurcation of the great vessels. This system is indicated in the treatment of lumbar or lumbosacral (L1-SI) spine instability as a result of fracture (including dislocation and subluxation), tumor, degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), pseudoarthrosis, spondylolisthesis, scoliosis, lordotic deformities of the spine, spinal stenosis, or a failed previous fusion.

FDA Enforcement
Class II ·Terminated·Zimmer, Inc.·November 27, 2013

Universal Clamp¿ System (IFU reference: SNA027-N-90001). Provides the stability required for solid bone fusion and helps reduce spinal deformities and fractures.

FDA Enforcement
Class II ·Terminated·Zimmer Spine, Inc.·March 30, 2016

Vitality¿ Spinal Fixation System. Thoracolumbosacral pedicle screw system (non-sterile). Pedicle screw fixation is indicated for skeletally mature patients and for adolescent patients. For use in Orthopedic medical specialty area. Product Usage: The Vitality Shear-off Set Screw is not threading properly with the mating tulip head of the Vitality screws, hooks and connectors due to a manufacturing issue. These devices are indicated as an adjunct to fusion for various indications

FDA Enforcement
Class II ·Terminated·Zimmer Biomet Spine Inc.·March 6, 2019

Vitality¿ Spinal Fixation System. Spinal Interlaminal, Appliance, Fixation, (non-sterile). Pedicle screw fixation is indicated for skeletally mature patients and for adolescent patients. For use in Orthopedic medical specialty area. Product Usage: The Vitality Shear-off Set Screw is not threading properly with the mating tulip head of the Vitality screws, hooks and connectors due to a manufacturing issue. These devices are indicated as an adjunct to fusion for various indications.

FDA Enforcement
Class II ·Terminated·Zimmer Biomet Spine Inc.·March 6, 2019

Vitality¿ Spinal Fixation System.Spinal Intervertebral Body, Appliance, Fixation (non-sterile). Pedicle screw fixation is indicated for skeletally mature patients and for adolescent patients. For use in Orthopedic medical specialty area. Product Usage: The Vitality Shear-off Set Screw is not threading properly with the mating tulip head of the Vitality screws, hooks and connectors due to a manufacturing issue. These devices are indicated as an adjunct to fusion for various indications

FDA Enforcement
Class II ·Terminated·Zimmer Biomet Spine Inc.·March 6, 2019

Vitality Spinal Fixation System, Vitality T27 Final Drivers and Vitality Torque Limiting Handle  90 in-lbs Model Number(s): 07.02066.001, 07.02053.001, 730M0017

FDA Enforcement
Class II ·Terminated·Zimmer Biomet Spine Inc.·June 14, 2017

Vitality Polyaxial Screw, 7.5mmx 50mm, REF: 07.02000.118, used with Vitality and Vital Spinal Fixation System

FDA Enforcement
Class II ·Ongoing·Zimmer Biomet Spine Inc.·January 10, 2024