10,000 results · 22ms · Sources: EU EUDAMED, US FDA

Get notified when this changes

We'll email you when new records match this search — new devices, new clearances, certificate changes, or withdrawals.

Picis ED PulseCheck-Software, transmission & storage, patient data Service Pack v5.0 L and M This product is a non-alarming software patient information system that compiles an electronic medical record utilizing commonly available hardware. A patient record is populated with information from various sources, such as health care professionals, medical devices connected to the system, and data that arrives via hospital and laboratory information systems. The application stores this information in a database and displays it to healthcare providers in different formats for informational purposes. The product is intended for use by healthcare professionals.

FDA Recall
Terminated ·Picis Inc.·Product code NSX·August 1, 2011

AdvanDx E. coli/P. aeruginosa PNA FISH, In Vitro Diagnostic Culture Identification Kit for Escherichia coli and Pseudomonas aeruginosa Catalog Number : KT007 Usage: E. coli/P. aeruginosa PNA FISH is a multicolor, qualitative nucleic acid hybridization assay intended for identification of Escherichia coli and Pseudomonas aeruginosa on smears of positive blood cultures containing Gram-negative rods. The E.coli/P. aeruginosa PNA FISH assay is indicated for use as an aid in the diagnosis of E. coli and/or P. aeruginosa bacteremia.

FDA Recall
Terminated ·Advandx Inc·Product code JSS·September 14, 2012

iChem VELOCITY Automated Urine Chemistry System, Catalog #700-7176-001 and iChem VELOCITY Automated Urine Chemistry System Computerless, Catalog #700-7177-001. The iChemVELOCITY automated urine chemistry system is an in-vitro diagnostic device used to automate the urine chemistry analysis profile using iChemVELOCITY Urine Chemistry Strips. The iChemVELOCITY can be used as a stand-alone system, as well as in a iQ200 Series system, a configuration given the proprietary name iRICELL as it is designed to be hardware and software compatible with iQ200 Series systems.

FDA Recall
Terminated ·Beckman Coulter Inc.·Product code KQO·March 29, 2018

EAR PACK CONTENTS: (I) CAUTERY PENC IL ROCKER SW I TI-I CH ( I ) EMESIS BASIN l Oin 700cc (2) LABEL FOR SKIN MARKERS ( I) NEEDLE HYPODERMIC 1 80 X I Y, ( I) WASI-l BASIN ROUND 6QT (I) INSTRUMENT POUCH 7 X I I 2 COMPART (I) STRIP STER I CLOSURE W' X 4" LIF (I) SYRINGE 3cc W/0 NEEDLE LILOCK L/F (2) SY RI NGE I ML W/0 NEEDLE LILOCK LIF ( I ) CAUTERY POLISHER TI P LIF ( I) SH EET ENT SPLIT 11 0 X 77 (2) LITE GLOVE (2) NEEDLE H YPODERM IC 27G X I \!..'' (1 2) TOWELS CLOTH HUCK (BLUE) ( I ) TUBE SUCTION CONNECT.'!." X 12' L/F ( I ) EAR ULCER SYRINGE 2oz LIF ( I ) TABLE COYER REINFORCED 50" X 90" LIF ( I ) UTILITY BOWL 1 6oz LIF (4) COTrON APPLICATOR 6" WOOD ( I ) INSTRUMENT WIPE I MM 8.25 X 8.25 ( I ) MAYO STAND COYER REINFORCED LIF ( I ) NEEDLE & BLADE COUNTER 20c FOAM/MAG LIF ( I ) SKIN MARK ER W/R ULER ( I ) SYRINGE IOcc W/0 NEEDLE LILOCK LIF ( I ) TRAY MAYO SMALL ( I ) SYRING E IOcc TI P CONTROL LILOCK LIF ( I ) DRAPE MICROSCOPE ZEI SS ( I ) TOWELS ABSORBENT 1 5'' X 20" LIF ( I ) TIME OUT BEACON NON WOV EN ST LIF ( I ) BLADE M INUATURE CARBON STEEL ( I 0) GAUZE SPONGE 4" X 4" 1 6PLY XRD LIF ( I ) NEEDLE BLUNT FI LL 1 80 X I Y, (2) SCALPEL SAFETY WEIGHTED # 1 5 ( I ) GOWN SURG, I MP ER. M I CROCOOL LG E (2) GOWN XL SURG ICAL MICROCOOL ( I ) MERLINO SKIN PREP APPLIC. 39ML LIF ( I ) WRAPPER 24" X 24" WET SKIN PACK CONTA INING: ( I ) WRAPPER 30" X 30" ( I ) TRAY 3/COMPARTM ENT ( I ) PYP SCRUB SOLUTI ON 4oz. BOTrLE (3) TI P ABSORBENT APPLICATOR STICK SPONGE (3) TOWELS ABSORBENT 15" X 20" L/F (6) SPONGE WING SMALL LIF (2) GLOVE MED FREETOUCI-1 VYN I L P/F (2) COTrON APPLICATOR 6" WOOD Product Usage: EO sterilized surgical convenient packs packaged into polyester/polyethylene breather bag with Tyvek double vents.

FDA Recall
Terminated ·Customed, Inc Calle Igualdad Final # 7·Product code OGR·May 20, 2014

15776-20 REG ANES W/DRUGS

FDA Recall
Terminated ·Smiths Medical ASD, Inc.·Product code CAZ·July 2, 2004

15548-20 REG ANES W/DRUGS

FDA Recall
Terminated ·Smiths Medical ASD, Inc.·Product code CAZ·July 2, 2004

Anesthesia circuit kit; CIRCUIT,ANES,EXTENDFLEX,120,LF DYNJAA10230

FDA Recall
Open, Classified ·Product code CAH·October 10, 2025

Double foot switch, type KF 2 1S/1 S-MED-AP, manufactured by the company Seute Schaltgerate. GmbH & Co. KG for Ziehm Imaging GmbH Germany, and used with Ziehm Imaging GmbH Mobile C-arm as a component thereof. Two versions were made: 2 pedal version KF 2 1S/1 S-MED-AP foot switch and 4 pedal foot switch version KF 2 1S/1 S-MED-AP This type of foot switch includes a pair of the dual foot switches assembled on a single metal bracket. The following labels may appear on the foot switch: Labeled in part: "Fluoro- Store***ZIN Part no. # 58371***ZIR Part no. # 10-2985*** Left Pedal: Initiate Radiation***Right Pedal: Store Image***" Labeled in part: "Fluoro - Cine***ZIN Part no. # 58415***ZIR Part no. # 10-2987*** Left Pedal: Initiate Radiation***Right Pedal: Switch into Cine mode***" Labeled in part: "Fluoro - Mag***ZIN Part no. # 58413***ZIR Part no. # 10-2989*** Left Pedal: Initiate Radiation***Right Pedal: Switch through magnification***" Labeled in part: "Fluoro -Snap***ZIN Part no. # 58417***ZIR Part no. # 10-2991*** Left Pedal: Initiate Radiation ***Right Pedal: Initiate Snapshot***" Labeled in part: "DSA - CINE***ZIN Part no. # 58419***ZIR Part no. # 10-2993*** Left Pedal: Switch into DSA mode ***Right Pedal: Switch into Cine mode***" Labeled in part: "Cine - Store***ZIN Part no. # 58421***ZIR Part no. # 10-2995*** Left Pedal: Switch into Cine mode***Right Pedal: Store Image***" Labeled in part: "Cine - LONG:Endo ON/OFF & SHORT:Freeze*** ZIN Part no. # 58423***ZIR Part no. # 10-2997*** Left Pedal: Switch into Cine mode***Right Pedal: Long: Switch Endo On/Off Short: Freeze the endoscopic image on live screen***" Labeled in part: "Cine- Endo ON /OFF***ZIN Part no. # 58425***ZIR Part no. # 10-2999*** Left Pedal: Switch into Cine mode***Right Pedal: Switch Endo On / Off***" Labeled in part: "Fluoro - Swap***ZIN Part no. # 58427***ZIR Part no. # 10-3031*** Left Pedal: Initiate Radiation***Right Pedal: Swaps the image between the live and reference screens***" Labeled in part: "DSA / MSA/RSA - OFF***ZIN Part no. #58429***ZIR Part no. #10-3033***Left Pedal: Switch DSA/MSA/RSA On***Right Pedal: Switch DSA/MSA/RSA Off***" The KF 2 1S/1S-MED- AP foot switch is a component of the Mobile C-arm and is used by the physician to activate Fluoroscopic X-Ray for imaging by pressing the foot switch.

FDA Recall
Terminated ·Ziehm Imaging Inc·Product code JAA·April 29, 2011

Description/REF: EPIDURAL CATHETER KIT: 19 GA X 90 CM/ASK-05502-VM1; EPIDURAL CATHETERIZATION KIT: 19 GA/AK-05501; EPIDURAL CATHETERIZATION KIT/AK-05502; EPIDURAL CATHETERIZATION KIT/AK-05502D; EPIDURAL CATHETERIZATION KIT/AK-05503; EPIDURAL CATHETERIZATION KIT/AK-05503-L; SPINAL ANES/EPIDURAL CATH KIT/AK-05560; SPINAL ANES/EPIDURAL CATH KIT/ASK-02520-SBMC1; EPIDURAL CATHETERIZATION KIT/ASK-05400-BW1; EPIDURAL CATHETERIZATION KIT/ASK-05400-GH; SPINAL ANES/EPIDURAL CATH KIT/ASK-05401-LMC; EPIDURAL CATHETERIZATION KIT/ASK-05401-NM; SPINAL ANES/EPIDURAL CATH KIT/ASK-05500-BID1; EPIDURAL CATHETERIZATION KIT: 19 GA/ASK-05500-JHH1; EPIDURAL CATHETERIZATION KIT: 19 GA/ASK-05500-MCV1; EPIDURAL CATHETER KIT: 19GA X 90CM ASK-05500-MVH; EPIDURAL CATHETER KIT: 19 GA X 90 CM/ASK-05500-UMC; 19 GA X 35.5 IN EPIDURAL CATHETER KIT/ASK-05502-MLH; SPINAL ANES/EPIDURAL CATH KIT/ASK-05560-JMH1; SPINAL ANES/EPIDURAL CATH KIT/ASK-05560-MKD2; SPINAL ANES/EPIDURAL CATH KIT/ASK-05560-OM1; EPIDURAL CATHETERIZATION KIT/ASK-17019-SM; EPIDURAL CATHETERIZATION KIT/BP-05501; EPIDURAL CATHETERIZATION KIT/CK-05401; EPIDURAL CATHETERIZATION KIT/HS-05501; EPIDURAL CATHETERIZATION KIT/MM-05501; EPIDURAL CATHETERIZATION KIT: 19 GA/MP-17019-TK; EPIDURAL CATHETERIZATION KIT: 19 GA/MP-17019-TKD; EPIDURAL CATHETERIZATION KIT: 19 GA/MP-17019-TKL; EPIDURAL CATHETERIZATION KIT/MSO-05401-JMH; EPIDURAL CATHETERIZATION KIT/NM-05401; EPIDURAL CATHETERIZATION KIT/SJ-05501; EPIDURAL CATHETERIZATION KIT/SM-05401; EPIDURAL CATHETER KIT: 19 GA X 90 CM/TM-05401; EPIDURAL CATHETERIZATION KIT/TM-05502; SPINAL ANES/EPIDURAL CATH KIT/UI-05502; SPINAL ANES/EPIDURAL CATH KIT: 19 GA/ASK-05400-SHM; EPIDURAL CATH KIT: 19 GA/ASK-05400-UOM; EPIDURAL CATHETER KIT: 19 GA X 90 CM/ASK-05500-MR; EPIDURAL CATHETERIZATION KIT: 19 GA/ASK-05500-TM; EPIDURAL CATHETERIZATION KIT/ASK-05501-BHL1; EPIDURAL CATHETERIZATION KIT/ASK-05501-GH; EPIDURAL CATHETER KIT: 19 GA X 90 CM/ASK-05501-SM; EPIDURAL CATHETERIZATION KIT/ASK-05502-BSM; EPIDURAL CATHETERIZATION KIT/ASK-05502-MGH1; EPIDURAL CATHETERIZATION KIT/ASK-05503-BWB1; EPIDURAL CATHETERIZATION KIT/ASK-05503-HMH; EPIDURAL CATHETER KIT: 19 GA X 90 CM/ASK-05503-SPH; EPIDURAL CATHETER KIT: 19 GA X 90 CM/ASK-05503-UPM1; SPINAL ANES/EPIDURAL CATH KIT/ASK-05560-UCI2; EPIDURAL CATHETERIZATION KIT: 19 GA/ASK-17019-UMP; EPIDURAL CATHETERIZATION KIT/MH-05503-1; EPIDURAL CATHETERIZATION KIT/ASK-05401-VB2; Epidural Catheterization Kit: 19GA/ASK-05500-SC1; Epidural Catheterization Kit: 19GA/ASK-05500-SC3; EPIDURAL CATHETER KIT: 19 GA X 90 CM/ASK-05501-AFH1; EPIDURAL CATHETER KIT: 19 GA X 90 CM/ASK-05501-BMC; EPIDURAL CATHETERIZATION KIT/ASK-05502-NY; EPIDURAL CATHETERIZATION KIT/ASK-17019-RMH

FDA Recall
Open, Classified ·ARROW INTERNATIONAL, LLC·Product code BSO·April 21, 2026

Medline convenience kits containing semi-rigid suction liners labeled as follows: ANES TURNOVER KIT-LF, Pack Number DYNJAA10338J

FDA Recall
Open, Classified ·MEDLINE INDUSTRIES, LP Northfield·Product code OKG·June 27, 2024

Medline Convenience kits labeled as: 1) FILTER-.8 MICRON, Pack Number 2008; 2) ANES CIRCUIT 90IN EXP-LF, Pack Number DYNJAA10295A

FDA Recall
Open, Classified ·MEDLINE INDUSTRIES, LP Northfield·Product code CAH·April 8, 2024

1 Liter Latex-Free Breathing Bags; Reservoir Bag; Vendor Part Number: 720059B, Medline Item Number: 40056; Available in various Anesthesia Circuit Kits and Complete Delivery System kits including: 1) Item Number CDS980230I, NICU-OR CDS; 2) Item Number DYNJ22691, Basin Supply Pack; 3) Item Number DYNJ24724, Spine-Crani Anesthesia Kit; 4) Item Number DYNJAAHY11, Hyperinflation System-UHS-1L; 5) Item Number DYNJAP0010, Anesthesia Circuit Ped-LF; 6) Item Number DYNJAP0011A, Pediatric Circuit-LF; 7) Item Number DYNJAP0012, Pediatric Anesthesia 40 In. CI; 8) Item Number DYNJAP0100, Pedi Breathing Circuit-LF; 9) Item Number DYNJAP0101, Anesthesia Circuit-Ped; 10) Item Number DYNJAP4012, Anesthesia Circuit Ped; 11) Item Number DYNJAP4013, Anesthesia Circuit; 12) Item Number DYNJAP4702A, Anesth Circuit Ped GS Line; 13) Item Number DYNJAP4707, Anesth Circuit 40in Ped-LF; 14) Item Number DYNJAP4722, Anes Cir 40 Ped GSEPW HYBABYH; 15) Item Number DYNJAP4729A, Circ Ped Anes Super-LF; 16) Item Number DYNJAP4730A, Circuit Pediatric Anesthesia; 17) Item Number DYNJAP4732, Anesth Circ Ped 40in 2B/V; 18) Item Number DYNJAP4740, Anesth Circ 40in Ped; 19) Item Number DYNJAP6101, Anesthesia Circuit; 20) Item Number DYNJAP6105, Anesth Circuit 60in Ped; 21) Item Number DYNJAP6106, Anes Circ Ped 60in BI GSE-LF; 22) Item Number DYNJAP6107, Anesth Circ Ped 60in ANG HME; 23) Item Number DYNJAP6108, Anesth Circuit 60in Ped; 24) Item Number DYNJAP6109, Anesth Circ Ped 60in B/V 1L-LF; 25) Item Number DYNJAP6111, Anes Cir Ped 60 GSEPW PALL FIL; 26) Item Number DYNJAP6112, Anesthesia-Peds Circuit; 27) Item Number DYNJAP6113, Circuit Pedi 60in; 28) Item Number DYNJAP6114, Anesth Circ 60in Ped; 29) Item Number DYNJAP6116, Anesth Circ 60in Ped; 30) Item Number DYNJAP6120A, Pediatric Circuit 40in LF; 31) Item Number DYNJAP6124, Anesth Circ Pedi 60in 1L GSL; 32) Item Number DYNJAP6127, Anes Circ Pedi 60in-LF; 33) Item Number DYNJAP6130, Anesth Circ Ped 60in 1L-LF; 34) Item Number DYNJAP6132A, Circuit Pediatric Anesthesia; 35) Item Number DYNJAP6133, Anesth Circuit Peds 60in-LF; 36) Item Number DYNJAP6136, Circuit Peds Anesthesia; 37) Item Number DYNJAP6137, Circuit Pediatric Anesthesia; 38) Item Number DYNJAP7217A, Anesth Circuit 72in Exp Ped BI; 39) Item Number DYNJAP7225A, Circuit Pediatric Anesthesia; 40) Item Number DYNJAP7227, Anes. 90in Exp Pedi -LF; 41) Item Number DYNJAP7233, Anes. Circuit 90in Exp Pedi-LF; 42) Item Number DYNJAP7234A, Anesthesia 72in Pediatric Exp; 43) Item Number DYNJAP7235A, Anesth Circ 72in Ped; 44) Item Number DYNJAP7236A, Anesthesia Pedi 72in; 45) Item Number DYNJAP7237, Circuit Pedi 90in EXP; 46) Item Number DYNJAP7241A, Circuit Pediatric Anesthesia; 47) Item Number DYNJAP7243B, Circ Anesth Ped 2 B/V LFree; 48) Item Number DYNJAP7246C, Circuit Pediatric Anesthesia; 49) Item Number DYNJAP7247, Anes Circ Peds 90in Exp; 50) Item Number DYNJAP7248, Anesth Circ Ped 72in Exp; 51) Item Number DYNJAP7261, Circuit Pediatric Anesthesia; 52) Item Number DYNJAP7262, Circuit Pediatric Anesthesia; 53) Item Number DYNJAP7263, Pediatric Anesthesia Circuits; 54) Item Number DYNJAP9005, Anesthesia Circuit; 55) Item Number DYNJAP9721A, Anesth Circuit Pedi HMEF LF; 56) Item Number DYNJAP9725, Pedi Expand Circuit; 57) Item Number DYNJAP9726, Anesth Circ Ped 90in; 58) Item Number DYNJAP9729, Anesth Circ 90in Exp Ped; 59) Item Number DYNJAP9730A, Circuit Pediatric 60in CORR-LF; 60) Item Number DYNJAP9732A, Circuit Pediatric Anesthesia; 61) Item Number DYNJAP9735, Peds Circuit; 62) Item Number DYNJAP9739, Circuit Pediatric Anesthesia; 63) Item Number DYNJAP9740, Circuit Pediatric Anesthesia; 64) Item Number DYNJAP9743, Circuit Pediatric Anesthesia; 65) Item Number DYNJAPF6003, Anesth Circ 60in Ped Unilimb; 66) Item Number DYNJAPF6005A, Anesth Circ 60in Uni Peds; 67) Item Number DYNJAPF6006, Anes Circ Peds 60in Uni; 68) Item Number DYNJAPF6009, Peds Anesthesia Circuit-LF; 69) Item Number DYNJAPF6011, Circuit Pediatric Anesthesia; 70) Item Number DYNJAPF601

FDA Recall
Terminated ·Medline Industries Inc·Product code BTC·December 7, 2007

RayStation/RayPlan- designed for treatment planning and analysis of radiation therapy. Software Version: 6.0.0.24 , 6.1.0.26 , 6.1.1.2 , 6.2.0.7 , 6.3.0.6 , 7.0.0.19 , 8.0.0.61 , 8.0.1.10 , 8.1.0.47 , 8.1.1.8 , 8.1.2.5 , 9.0.0.113 , 9.1.0.933 , 9.2.0.483 . Including Service Paks: Product name (build number) UDI-DI RayStation 6/RayPlan 2 (6.0.0.24) 07350002010013 RayStation 6/RayPlan 2 Service Pack 1 (6.1.1.2) 07350002010082 RayStation 6/RayPlan 2 Service Pack 2 (6.2.0.7) 07350002010075 RayStation 6/RayPlan 2 Service Pack 3 (6.3.0.6) 07350002010242 RayStation/RayPlan 7 (7.0.0.19) 07350002010068 RayStation/RayPlan 8A (8.0.0.61) 07350002010112 RayStation/RayPlan 8A Service Pack 1 (8.0.1.10) 07350002010136 RayStation/RayPlan 8B (8.1.0.47) 07350002010129 RayStation/RayPlan 8B Service Pack 1 (8.1.1.8) 07350002010204 RayStation/RayPlan 8B Service Pack 2 (8.1.2.5) 07350002010235 RayStation/RayPlan 9A (9.0.0.113) 07350002010174 RayStation/RayPlan 9B (9.1.0.933) 07350002010266 RayStation/RayPlan 9B Service Pack 1 (9.2.0.483) 07350002010297

FDA Recall
Open, Classified ·RAYSEARCH LABORATORIES AB Sveavagen 9 Stockholm Sweden·Product code MUJ·December 30, 2021

Zimmer NexGen Complete Knee Solution Minimally Invasive Solutions Procedures Trabecular Metal Technology Tibial Tray, fixed bearing, size 8, sterile, Zimmer, Warsaw, Indiana; REF 00-5954-057-02. The product is used as an implant for knee replacement.

FDA Recall
Terminated ·Zimmer Inc.·Product code JWH·November 16, 2009

Anesthesia Circuit Kits and other various kits that contain Anesthesia Circuits; Product description/Product numbers: ADULT 120 EXPANDABLE W/MASK DYNJAA10591; ANES CIRC 120IN EXP-LF DYNJAA6555G; ANES CIRCUIT ADULT 120"-LF DYNJAA10817; ANESTHESIA 120" ADLT-LF DYNJAA10775; ANESTHESIA CIRC ADULT 120-LF DYNJAA10601; ANESTHESIA CIRCUIT - LF DYNJAA10261B; ANESTHESIA CIRCUIT 120EXP-LF DYNJAA10741A; ANESTHESIA CIRCUIT ADULT-LF DYNJAA0380A DYNJAA10641 DYNJAA10706B DYNJAA10851 DYNJAA10922B DYNJAA10971A DYNJAA11030A DYNJAA11087 DYNJAA11126; ANESTHESIA CIRCUIT-LF DYNJAA0309A DYNJAA0368A DYNJAA10368A DYNJAA10392 DYNJAA10430A DYNJAA10547A DYNJAA10639A DYNJAA10656A DYNJAA10685A DYNJAA10685B; CIRC 120" EXP 1 BV HMEF 3L GSL DYNJAA10920; EXPANDABLE CIRCUIT-LF DYNJAA11095; NM ANESTHESIA TURNOVER KIT DYNJAA0433; PROV HEALTH HEPA CIRC #2-LF DYNJAA0360; SPTMPX01IA CIRCUIT ADULT-LF DYNJAA10973A;

FDA Recall
Open, Classified ·Product code CAI·October 10, 2025

V-Probe, Endocare Cryo V Probe model # Cryo 206V. The product is used in a minimally invasive, percutaneous approach to treating prostate cancer in low, moderate and high risk patients. Prostate Cryoablation uses extremely cold temperatures to destroy cancerous tissue.

FDA Recall
Terminated ·Endocare, a Wholly Owned Subsidiary of HealthTronics, Inc.·Product code GEH·December 5, 2008

V-Probe, Endocare Cryo V Probe, single unit model # CVA2400. The product is used in a minimally invasive, percutaneous approach to treating prostate cancer in low, moderate and high risk patients. Prostate Cryoablation uses extremely cold temperatures to destroy cancerous tissue.

FDA Recall
Terminated ·Endocare, a Wholly Owned Subsidiary of HealthTronics, Inc.·Product code GEH·December 5, 2008

Biomet Sports Medii cine Juggerknot Long Flex Drill Bit with Sleeve Nitinol intended to be used for soft tissue to bone fixation with indications for use in: Shoulder, Foot and Ankle, Knee, Hand and Wrist and Hip repair.Stainless Steel, Sterile Item Number: 110016992

FDA Recall
Terminated ·Zimmer Biomet, Inc.·Product code MBI·August 3, 2018

Owner's Booklets and Instructions for Use that are used with the following blood glucose measurement devices. Description/Item: TRUE METRIX PRO Meter Only/RE4H01P-40, TRUE METRIX PRO Starter Kit/RE4H01P-43, PROCURE TRUE METRIX PRO Meter Only/RE4212P-00, Henry Schein TRUE METRIX PRO Meter Only/RE4099P-40, Henry Schein TRUE METRIX PRO Kit/RE4099P-43, McKESSON TRUE METRIX PRO Meter Only/RE4051P-00, Moore Medical TRUE METRIX PRO Meter Only/RE4068P-01.

FDA Recall
Open, Classified ·Trividia Health, Inc.·Product code NBW·February 6, 2026

Extension Set utilized in gravity IV administration sets and pump administration sets utilized with BBMI's Infusomat Space Large Volume Pump, Outlook Pump, and Vista Basic Pump. Labeled as the following with corresponding catalog number: 1. ANES SET W/DUAL FEM.LL SAFEPORT MANIFOLD; Catalog Number: 456520.

FDA Recall
Open, Classified ·B Braun Medical Inc·Product code FPA·October 29, 2025