195 results
·
14ms
·
Sources: EU EUDAMED, US FDA
EZ Steer ThermoCool Nav Part Number D-1292-04-S Diagnostic/Ablation Catheter instructions for use. The Biosense EZ STEER~ THERMOCOOL~ NAV Diagnostic/Ablation Deflectable Tip Catheter is a multi-electrode luminal catheter with a deflectable tip designed to facilitate electrophysiological mapping of the heart and to transmit radiofrequency (RF) current to the catheter tip electrode for ablation purposes. The catheter shaft measures 7.5 F with 8 F ring electrodes. For ablation, the catheter is used in conjunction with an RF generator and a dispersive pad (indifferent electrode) for the treatment of: - Type I atrial flutter in patients age 18 or older. - Recurrent drug/device refractory sustained monomorphic ventricular tachycardia (VT) due to prior myocardial infarction (Mil in adults. - Drug refractory recurrent symptomatic paroxysmal atrial fibrillation, when used with compatible three-dimensional electroanatomic mapping systems. The EZ STEER~ THERMOCOOL~ NAV Diagnostic/Ablation Deflectable Tip Catheter provides location information when used with CARTO~ EP Navigation Systems.
FDA Recall
Terminated
·Biosense Webster, Inc.·Product code OAE·November 22, 2010
EZ Steer ThermoCool Nav Part Number D-1292-02-S Diagnostic/Ablation Catheter instructions for use. The Biosense EZ STEER~ THERMOCOOL~ NAV Diagnostic/Ablation Deflectable Tip Catheter is a multi-electrode luminal catheter with a deflectable tip designed to facilitate electrophysiological mapping of the heart and to transmit radiofrequency (RF) current to the catheter tip electrode for ablation purposes. The catheter shaft measures 7.5 F with 8 F ring electrodes. For ablation, the catheter is used in conjunction with an RF generator and a dispersive pad (indifferent electrode) for the treatment of: - Type I atrial flutter in patients age 18 or older. - Recurrent drug/device refractory sustained monomorphic ventricular tachycardia (VT) due to prior myocardial infarction (Mil in adults. - Drug refractory recurrent symptomatic paroxysmal atrial fibrillation, when used with compatible three-dimensional electroanatomic mapping systems. The EZ STEER~ THERMOCOOL~ NAV Diagnostic/Ablation Deflectable Tip Catheter provides location information when used with CARTO~ EP Navigation Systems.
FDA Recall
Terminated
·Biosense Webster, Inc.·Product code OAE·November 22, 2010
TactiCath Quartz Contact Force Ablation Catheter, Model Numbers: PN-004 065 (GTIN 07640157990033) and PN-004 075 (GTIN 07640157990040) - Product Usage: is a multi-electrode irrigated catheter with a deflectable tip designed to allow electrophysiological mapping of the heart and, when connected to an RF generator, to deliver radiofrequency current to the catheter tip electrode for the purpose of ablation.
FDA Recall
Terminated
·Abbott·Product code OAE·May 22, 2020
EZ Steer ThermoCool Nav Part Number D-1292-03-S Diagnostic/Ablation Catheter instructions for use. The Biosense EZ STEER~ THERMOCOOL~ NAV Diagnostic/Ablation Deflectable Tip Catheter is a multi-electrode luminal catheter with a deflectable tip designed to facilitate electrophysiological mapping of the heart and to transmit radiofrequency (RF) current to the catheter tip electrode for ablation purposes. The catheter shaft measures 7.5 F with 8 F ring electrodes. For ablation, the catheter is used in conjunction with an RF generator and a dispersive pad (indifferent electrode) for the treatment of: - Type I atrial flutter in patients age 18 or older. - Recurrent drug/device refractory sustained monomorphic ventricular tachycardia (VT) due to prior myocardial infarction (Mil in adults. - Drug refractory recurrent symptomatic paroxysmal atrial fibrillation, when used with compatible three-dimensional electroanatomic mapping systems. The EZ STEER~ THERMOCOOL~ NAV Diagnostic/Ablation Deflectable Tip Catheter provides location information when used with CARTO~ EP Navigation Systems.
FDA Recall
Terminated
·Biosense Webster, Inc.·Product code OAE·November 22, 2010
SMARTABLATE RF Generator System, Catalog No. M490006, M490007, M4900106, and M4900107. Product Usage: The use of the SMART ABLATE Generator and all accessories is indicated in combination with compatible therapeutic catheters for use in conventional intracardiac RF ablation procedures. The SMARTABLATE Foot Pedal is designed to initiate or discontinue operation of the SMARTABLATE System. The Foot Pedal can be connected to the SMARTABLATE RF Generator, SMARTABLATE Irrigation Pump; or SMARTABLATE Remote Control.
FDA Recall
Terminated
·Biosense Webster, Inc.·Product code OAE·March 19, 2015
EZ Steer ThermoCool Nav Part Number D-1292-05-S Diagnostic/Ablation Catheter instructions for use. The Biosense EZ STEER~ THERMOCOOL~ NAV Diagnostic/Ablation Deflectable Tip Catheter is a multi-electrode luminal catheter with a deflectable tip designed to facilitate electrophysiological mapping of the heart and to transmit radiofrequency (RF) current to the catheter tip electrode for ablation purposes. The catheter shaft measures 7.5 F with 8 F ring electrodes. For ablation, the catheter is used in conjunction with an RF generator and a dispersive pad (indifferent electrode) for the treatment of: - Type I atrial flutter in patients age 18 or older. - Recurrent drug/device refractory sustained monomorphic ventricular tachycardia (VT) due to prior myocardial infarction (Mil in adults. - Drug refractory recurrent symptomatic paroxysmal atrial fibrillation, when used with compatible three-dimensional electroanatomic mapping systems. The EZ STEER~ THERMOCOOL~ NAV Diagnostic/Ablation Deflectable Tip Catheter provides location information when used with CARTO~ EP Navigation Systems.
FDA Recall
Terminated
·Biosense Webster, Inc.·Product code OAE·November 22, 2010
TactiSys Quartz Pack, PN-004 400. For percutaneous catheter radiofrequency (RF) ablation of atrial cardiac arrhythmias that allows visualization of the contact force between TactiCath quartz catheter tip and the heart wall. Product Usage: This device is indicated for use in cardiac electrophysiological mapping and for the treatment of drug refractory recurrent symptomatic paroxysmal atrial fibrillation, when used in conjunction with a compatible radiofrequency generator and three-dimensional mapping system.
FDA Recall
Terminated
·Product code OAE·November 25, 2014
EZ Steer ThermoCool Nav Part Number D-1292-01-S Diagnostic/Ablation Catheter instructions for use. The Biosense EZ STEER~ THERMOCOOL~ NAV Diagnostic/Ablation Deflectable Tip Catheter is a multi-electrode luminal catheter with a deflectable tip designed to facilitate electrophysiological mapping of the heart and to transmit radiofrequency (RF) current to the catheter tip electrode for ablation purposes. The catheter shaft measures 7.5 F with 8 F ring electrodes. For ablation, the catheter is used in conjunction with an RF generator and a dispersive pad (indifferent electrode) for the treatment of: - Type I atrial flutter in patients age 18 or older. - Recurrent drug/device refractory sustained monomorphic ventricular tachycardia (VT) due to prior myocardial infarction (Mil in adults. - Drug refractory recurrent symptomatic paroxysmal atrial fibrillation, when used with compatible three-dimensional electroanatomic mapping systems. The EZ STEER~ THERMOCOOL~ NAV Diagnostic/Ablation Deflectable Tip Catheter provides location information when used with CARTO~ EP Navigation Systems.
FDA Recall
Terminated
·Biosense Webster, Inc.·Product code OAE·November 22, 2010
TactiSys Quartz Equipment (with software version 1.7) Model: PN-004 400 Part Numbers: 600043767 (China), 100154367 (Global), 100154368 (SWAP)
FDA Recall
Terminated
·Abbott Laboratories Inc. (St Jude Medical) One·Product code OAE·April 5, 2019
Medtronic Arctic Front Catheter, Sterile EO, Medtronic CryoCath LP, Kirkland, Quebec, H9H 5 H3, Canada, Model 2AF282 and 2AF231 ( not distributed in US) Product Usage: The Medtronic CryoCath System consists of a Cryoablation console, cardiac Cryoablation catheters, connection components and accessories. The Arctic Front Cardiac Cryoablation Catheter is an over the wire Balloon catheter. The inside of the Balloon at the distal end of the Cryoablation Catheter reaches temperatures of -50C or colder when refrigerant is injected from the console to the inside of the balloon. Arctic Front Cardiac Cryoablation catheters are introduced into the vasculature by traditional minimally invasive techniques. The CryoConsole houses the electrical and mechanical components as well as proprietary software for controlling and recording a cryotherapy procedure with Arctic Front and/or the Freezor family of catheters. It stores and controls the delivery of the liquid refrigerant through the coaxial umbilical to the catheter, recovers the refrigerant vapor from the catheter under constant vacuum, and disposes of the refrigerant through the hospital scavenging system. Multiple features are built into the catheter and the CryoConsole system to ensure safety.
FDA Recall
Terminated
·Medtronic Inc. Cardiac Rhythm Disease Management·Product code OAE·August 29, 2011
HTA Console System, 230 Volt , French, Product Number: 56001FO (HTA system is a software-controlled hysteroscopic thermal endometrial ablation system)
FDA Recall
Terminated
·Boston Scientific Corporation One Boston·Product code MNB·January 24, 2007
Boston Scientific Mach 1 peripheral Guide Catheter 6F, HS Hockey Stick, .070 in (internal dia), Shaft lenght 55cm, Catalog Number: 19-600, UPN M001196000, Sterile EO, Availmed S.A. de C.V. (Mexico), Boston Scientific Corp., Maple Grove, MN 55311
FDA Recall
Terminated
·Boston Scientific Corporation One Boston·Product code DQY·February 7, 2008
Datex-Ohmeda Aestiva/5 Active Gas Scavenging System, used with a Model 7100 Ventillator, on a Aestiva/5 Anesthesia Machine.
FDA Recall
Terminated
·Datex-Ohmeda Inc One Ohmeda·Product code CBN·April 16, 2004
Renegade Hi-Flo Microcatheter Kits, Catalog/Order # 18-299, UPN M001182990
FDA Recall
Terminated
·Boston Scientific Corporation One Boston·Product code KRA·August 10, 2005
EndoVive Safety PEG Kits 24 F Universal Product Number (UPN): MOO56648 1 The product provides nutrition directly into the stomach of adult and pediatric patients who are unable to consume by conventional methods.
FDA Recall
Terminated
·Boston Scientific Corporation One Boston·Product code KNT·June 17, 2008
Datex-Ohmeda Aestiva/5 Active Gas Scavenging System used with a Model 7900 Ventillator, on a Aestiva/5 Anesthesia Machine
FDA Recall
Terminated
·Datex-Ohmeda Inc One Ohmeda·Product code CBN·April 16, 2004
Boston Scientific Impulse Flextrusion Shaft 5F FR4 16391-02 H74916391022, (5-Pack Carton Label), Angiographic Catheters. Made in Mexico Parque Industrial La Mesa Edificio G1, Suites B, H Tijuana, Baja California 22650 MEX Boston Scientific Impulse Flextrusion Shaft 5F FR4 16391-02 H74916391021, (Single Pack Carton/Pouch Label), Angiographic Catheters. Made in Mexico Parque Industrial La Mesa Edificio G1, Suites B, H Tijuana, Baja California 22650 MEX
FDA Recall
Terminated
·Boston Scientific Corporation One Boston·Product code DQO·June 4, 2007
Boston Scientific Scimed Maverick 2 Monorail" PTCA Catheter, 3.0 mm 15 mm REF 38928-1530 Lot 9565194 Use before 2010-04 Indicated for balloon dilation of the stenotic portion of a coronary artery or bypass graft stenosis for the purpose of improving myocardial perfusion.
FDA Recall
Terminated
·Boston Scientific Corporation One Boston·Product code LOX·May 1, 2007
Boston Scientific, Imager II Angiographic Catheter, (Outer Carton Label): UPN M001315081, 5 Fr, 100 cm, Catalog No. 31-508, Lot 48951, Description 5 Fr Flush TR, Sterile EO, Made in Ireland, Unit 7, 8 & 9, Annacotty Business Park, Annacotty, C. Limerick, Ireland ****Inner Pouch Label: Boston Scientific, Imager II Angiographic Catheter,UPN M001315080, 5 Fr, 100 cm, Catalog No. 31-508, Lot 48951, Description 5 Fr Flush TR, Sterile EO, Made in Ireland, Unit 7, 8 & 9, Annacotty Business Park, Annacotty, C. Limerick, Ireland
FDA Recall
Terminated
·Boston Scientific Corporation One Boston·Product code DQO·October 12, 2007
Boston Scientific Mach 1 Guide Catheter 6F, IM Internal Mammary 90cm, .070 in (internal dia), shaft lenght, 90 cm, Catalon Number: 34356-446, UPN H749343564460, Sterile EO, Availmed S.A. de C.V. (Mexico), Boston Scientific Corp., Maple Grove, MN 55311
FDA Recall
Terminated
·Boston Scientific Corporation One Boston·Product code DQY·February 7, 2008