3M Micropore Paper Tape, Cat. No. 1530-154, 1 in x 54 in., 800 rolls / case.
FDA Recall
Terminated
·Product code KGX·January 29, 2010
3M Micropore Paper Tape, Cat. No. 1530-15Y, 1 in x 5YDS., 441 rolls / case.
FDA Recall
Terminated
·Product code KGX·January 29, 2010
3M Micropore Paper Tape, Cat. No. 1530-336, 3 in x 36 in., 240 rolls / case.
FDA Recall
Terminated
·Product code KGX·January 29, 2010
3M Micropore Paper Tape, Cat. No. 1530-136, 1 in x 36 in., 800 rolls / case.
FDA Recall
Terminated
·Product code KGX·January 29, 2010
3M Micropore Paper Tape, Cat. No. 1530-118, 1 in x 18 in., 800 rolls / case.
FDA Recall
Terminated
·Product code KGX·January 29, 2010
3M Micropore Paper Tape, Cat. No. 1530-12Y, 1 in x 2YDS., 630 rolls / case.
FDA Recall
Terminated
·Product code KGX·January 29, 2010
3M Micropore Paper Tape, Cat. No. 1530-254, 2 in x 54 in., 400 rolls / case.
FDA Recall
Terminated
·Product code KGX·January 29, 2010
3M Micropore Single Use Rolls, Surgical Tape, REF 1530S-1, 1 in x 1-1/2 yd.
FDA Recall
Terminated
·Product code KGX·January 29, 2010
LMA Esophageal Intubation Detector (EID), Catalog Number EID100 The device is used to assist verification of placement of the endotracheal tube or esophageal/tracheal double lumen tube. This device is to be used as an adjunct to assess intubation. Its purpose is not to eliminate clinical judgment
FDA Recall
Terminated
·LMA North America Inc·Product code BTR·May 23, 2012
LMA- Unique Laryngeal Mask Airway Size 4, Catalog No. 12140, Lot FH041202 Size 4, Catalog No. 12150, Lot FJ021202
FDA Recall
Terminated
·LMA North America Inc·Product code CAE·June 18, 2003
LifeSync ECG System - Disposable leadwear, Ls-222, Ls-223
FDA Recall
Terminated
·GMP Companies/Lifesync Corporation·Product code DRG·January 10, 2007
Curix Opthos H, size 35x43 cm A radiographic medical x-ray film designed to optimize diagnostic chest imaging by providing complete diagnostic information including superbly visualized lung detail along with a high level of retro-cardiac, sub-diaphragmatic and mediastinal information.
FDA Recall
Terminated
·AGFA Corp.·Product code IWZ·October 4, 2011
Magellan Hypodermic Safety Needle, 25 G x 5/8" (0.508 mm x 1.6 cm). A single lumen needle intended to inject fluids into, or withdraw fluids from, parts of the body below the surface of the skin. Product Code: 8881850558
FDA Recall
Terminated
·Cardinal Health·Product code FMI·February 9, 2021
SOMATOM Force, System x-ray, tomography, computed
FDA Recall
Terminated
·Siemens Medical Solutions USA, Inc·Product code JAK·October 20, 2016
Magellan 3 mL Syringe with Hypodermic Safety Needle, 25 G x 5/8" (0.508 mm x 1.6 cm). A single lumen needle intended to inject fluids into, or withdraw fluids from, parts of the body below the surface of the skin. Product Code: 8881833558
FDA Recall
Terminated
·Cardinal Health·Product code FMI·February 9, 2021
VNS Therapy Programming System, Rx Only, Model 3000, v1.0.2.2
FDA Recall
Terminated
·LivaNova USA Inc·Product code LYJ·January 24, 2018
Taut Intraducer Peritoneal Catheter, 12 Fr x 10 Fr x 20.3 cm; a sterile, Rx peritoneal catheter for single use, individually packaged in a Tyvek/clear pouch; Taut Inc., 2561 Kaneville Ct., Geneva, IL 60134; the individually packaged, sterilirzed catheter was sold in two configurations: a) catalog number (REF) P.I.-128: 10 catheters per box, 10 boxes per case, and b) a sterile component of the convenience kit, catalog number (REF) 50000, System One Comprehensive Lap CBDE Kit
FDA Recall
Terminated
·Taut, Inc.·Product code GBW·January 19, 2007
Vagus Nerve Stimulation (VNS) Therapy Leads, PerenniaDURA, Model: 303. Model 303-20 PereniaDURA Lead (2.0 mm electrode inner diameter) and Model 303-30 PereniaDURA Lead (3.0 mm electrode inner diameter)
FDA Recall
Terminated
·LivaNova USA, Inc.·Product code LYJ·December 2, 2021
VNS Therapy, SenTiva, Model # 1000, (01)05425025750405, Rx Only for vagal nerve stimulation (VNS) therapy
FDA Recall
Terminated
·LivaNova USA Inc·Product code LYJ·August 22, 2019
LIFESTREAM Balloon Expandable Vascular Covered Stent . BARD PERIPHERAL VASCULAR. 6mm X 26mm X 80 Recommended Introducer 6F (2.00mm) NP 8atm (811 kPa) Recommended Guide wire .035" (0.89mm) RBP 12 atm (1216 kPa) RX Only Lot numbers begins with CMA or CMB. Product Code Stent Diameter Stent length Catheter Length LSM0800626 6mm 26 mm 80 cm LSM1350626 6 mm 26 mm 135 cm LSM0800637 6 mm 37 mm 80 cm LSM1350637 6 mm 37 mm 135 cm LSM0800726 7 mm 26 mm 80 cm LSM1350726 7 mm 26 mm 135 cm Product Usage: The LIFESTREAM Balloon Expandable Vascular Covered Stent is indicated for the treatment of atherosclerotic lesions in common and external iliac arteries with reference vessel diameters between 4.5 mm and 12.0 mm, and lesions lengths up to 100mm.
FDA Recall
Terminated
·Bard Peripheral Vascular Inc·Product code PRL·February 18, 2019