145 results
·
14ms
·
Sources: EU EUDAMED, US FDA
20-Pole Eco Cable, Catalog #EM-5050-060 Product Usage: The 20-Pole Eco Cable is intended to be used as an interface cable between the LASSO NAV Eco Catheter and CARTO 3 System.
FDA Recall
Terminated
·Biosense Webster, Inc.·Product code DQK·March 5, 2013
LASSO NAV Duo Loop eco Catheters, Catalog No. D-1354-01, D-1354-02, D-1354-03, D-1354-04, D-1354-05, D-1354-06. LASSO NAV DUO LOOP eco Catheter is indicated for multiple electrode electrophysiological mapping of the cardiac structures of the heart, i.e. recording or stimulation only. The catheter is designed to obtain electrograms in the atrial regions of the heart. LASSO NAV DUO LOOP eco Catheter provides location information when used with compatible CARTO 3 EP Navigation Systems.
FDA Recall
Terminated
·Biosense Webster, Inc.·Product code DRF·February 25, 2015
20-Pole LASSO Nav Catheter Eco, Catalog # D-1349-02S. Designed to facilitate electrophysiological mapping of the atria of the heart.
FDA Recall
Terminated
·Biosense Webster, Inc.·Product code DRF·June 19, 2013
ACUSON SC2000 Ultrasound Systems between software versions VA16A and VA30A and with the Stress Echo Option. Model number 10433816: The SC2000 ultrasound imaging system is intended for the following applications: Cardiac, Neo-natal and Fetal Cardiac, Pediatric, Transespohageal, Adult Cephalic, Peripheral Vessel, Abdominal, Abdominal Intraoperative, Intraoperative Neurological, Musculo-skeletal Conventional, and Musculo-skeletal Superficial applications. The system also provides the ability to measure anatomical structures and calculation packages that provide information to the clinician that may be used adjunctively with other medical data obtained by a physician for clinical diagnosis purposes.
FDA Recall
Terminated
·Siemens Medical Solutions USA, Inc.·Product code IYN·May 29, 2015
LiquaSonic Ultrasound Gel 5L, Model No. 001222
FDA Recall
Terminated
·Athena Medical Products Inc·Product code ITX·August 20, 2021
LiquaSonic Ultrasound Gel 250mL, Model No. 001205
FDA Recall
Terminated
·Athena Medical Products Inc·Product code ITX·August 20, 2021
IPL Coupling Gel, I L (AX1009013), 12 pack of 0.25 L (AX1009018), 6 pack of 1 L (AX1009019 or AX1009063); and IPL Coupling Gel or EcoGel 200, 0.25 L (AX1009012) manufactured by Eco-Med Pharmaceutical
FDA Recall
Terminated
·Lumenis, Inc.·Product code ITX·October 14, 2021
ACUSON SC2000 Ultrasound Systems with software version 3.5 (VA35) and using Stress Echo Feature. Ultrasound imaging system.
FDA Recall
Terminated
·Siemens Medical Solutions USA, Inc.·Product code IYN·April 23, 2014
IMPAX CV Echo Measurement Import via Optical Character Recognition (OCR) The IMPAX Cardiovascular suite is a cardiovascular Information system providing image archiving and image display and modality study-specific structured reporting.
FDA Recall
Terminated
·AGFA Corp.·Product code LLZ·June 6, 2011
Stryker Sustainability Solutions Reprocessed BW Lasso 2515 NAV eco Variable Diagnostic EP Catheters, Ref D134302, Sterile, Rx. The Reprocessed 2515 NAV eco Variable Electrophysiology (EP) Catheters are indicated for multiple electrode electrophysiological mapping of the cardiac structures of the heart, i.e. recording or stimulation only. They are designed to obtain electrograms in the atrial regions of the heart. The Reprocessed 2515 NAV eco Variable EP Catheters provide location information when used with compatible CARTO EP Navigation Systems version 2.3 or higher.
FDA Recall
Terminated
·Stryker Sustainability Solutions·Product code NLH·January 2, 2018
Stryker Sustainability Solutions Reprocessed BW Lasso 2515 NAV eco Variable Diagnostic EP Catheters, Ref D134301, Sterile, Rx. The Reprocessed 2515 NAV eco Variable Electrophysiology (EP) Catheters are indicated for multiple electrode electrophysiological mapping of the cardiac structures of the heart, i.e. recording or stimulation only. They are designed to obtain electrograms in the atrial regions of the heart. The Reprocessed 2515 NAV eco Variable EP Catheters provide location information when used with compatible CARTO EP Navigation Systems version 2.3 or higher.
FDA Recall
Terminated
·Stryker Sustainability Solutions·Product code NLH·January 2, 2018
Z6Ms transesophageal transducers used on ACUSON SC2000 ultrasound systems, Z6Ms model 10436113. Radiology: The ACUSON SC2000 ultrasound imaging system is intended for the following applications: Cardiac, Neo-natal and Fetal Cardiac, Pediatric, Transesophageal, Adult Cephalic, Peripheral Vessel, Abdominal, Abdominal Intraoperative, Intraoperative Neurological, Neurological-skeletal Conventional, and Musculo-skeletal Superficial applications. The system also provides the ability to measure anatomical structures and calculation packages that provide information to the clinician that may be used adjunctive with other medical data obtained by a physician for clinical diagnosis purposes.
FDA Recall
Terminated
·Siemens Medical Solutions USA, Inc.·Product code IYN·November 7, 2016
Biosense Webster's Reprocessed SOUNDSTAR eco Diagnostic Ultrasound Catheters, Catalog Nos: M-5723-115, Model Number BIO10438577.
FDA Recall
Terminated
·STERILMED, INC.·Product code OWQ·September 24, 2014
ANGIODYNAMICS Percutaneous Introducer Set under the following labels: 1) 4 F Stiffened Micro-Introducer Kit, 45CM SS/T NON-ECHO S PG, Item Number H787065970655, Catalog No.REF 06597065, 2) 4 F Stiffened Micro-Introducer Kit, STF 4F M.I. KIT 45CM NT/T NON-ECHO S PG, Item Number H787065970695, Catalog No.REF 06597069 Indicated for percutaneous introduction of guidewire or catheter into the vascular system following a small 21-gauge needle stick
FDA Recall
Terminated
·Angiodynamics, Inc.·Product code DYB·September 28, 2016
MPI Rapid Response HUT Table, Model #RRHUT 1217 with Dual 2 Way Drop Section. The firm name on the label is Medical Positioning Inc., Kansas City, MO. Designed for multiple uses including a conventional examination table, unexplained syncope, neurocardiogenic syncope, chronic fatigue syndrome, and most noninvasive procedures. With the optional drop section, the use expands to echo/stress echo/Doppler studies, and vascular and carotid echo.
FDA Recall
Terminated
·Medical Positioning Inc·Product code LGX·March 5, 2012
Echo Bi-Metric Press-Fit Stems/Echo Bi-Metric 11mm x 135mm Collarless Porous Stem (Orthopedic Implant) Indications: 1) Noninflammatory degenerative joint disease including osteoarthritis and avascular necrosis, 2) rheumatoid arthritis, 3) correction offunctional deformity, 4) treatment of non-union, femoral neck fracture, and trochanteric fractures of the proximal femur with head involvement, unmanageable using other techniques, 5) revision of previously failed total arthoplasty.
FDA Recall
Terminated
·Biomet, Inc.·Product code KWA·November 6, 2012
The EKOS cart has the catalog number 700-60101. The EKOS cart is a custom infusion stand/cart used to hold and transport the EkoSonic Control Unit. The cart is designed with three poles to hold infusion pumps and fluid bags, a tray on which the EkoSonic Control unit sits and a base designed to hold an Uninterruptable Power Supply (UPS). The cart mounts on 4 wheels, two locking and two non-locking.
FDA Recall
Terminated
·EKOS Corporation·Product code FOX·August 22, 2016
Econocare Plus Overlay Item: 1025EC. Intended to aid in the prevention and treatment of pressure injuries and general comfort - Product Usage: The EHOB WAFFLE Overlay intended use is as first line of defense for pressure injury prevention. The design provides the caregiver a point-of-care solution with the versatility of patient handling and transferring, which encourages ease of use and compliance. The design provides airflow to aid in patient comfort and pressure injury prevention.
FDA Recall
Terminated
·EHOB, Inc.·Product code IKY·January 19, 2020
EKOS EndoWave Infusion System and EKOS Lysus Infusion Systems - drug delivery catheters. EKOS Corporation Bothell, WA Packaging: *EndoWave(TM) Ultrasound Accelerated Thrombolysis (USAT) EKOS EndoWave Infusion System Drug Delivery Catheter with Ultrasound Core. and ''Lysus Infusion System''. EndoWave Infusion Systems 06, 2.7W, part #4599-001, catalog #500-52106; Systems 12, 2.7W, part #4599-002, catalog 500-52112; Systems 18, 2.7W, part #4599-003, catalog #500-52118; Systems 24, 2.7W, part #4599-004, catalog #500-52124; Systems 30, 2.7W, part #4599-005, catalog #500-52130; Systems 40, 2.7W, part 4599-006, catalog #500-52140; Systems 50, 2.7W, part #4599-007, catalog #500-52150; Systems 06, 3.5W, part #5199-001, catalog #500-54106; Systems 12, 3.5W, part #5199-002, catalog #500-54112; Systems 18, 3.5W, part #5199-003, catalog #500-54118; Systems 24, 3.5W, part #5199-004, catalog #500-54124; Systems 30, 3.5W, part #5199-005, catalog #500-54130, Systems 40, 3.5W, part #5199-006, catalog #500-54140; Systems 50, 3.5W, part #5199-007, catalog #500-54150; Lysus Infusion Systems 06, 2.7W, part #4599-001, catalog 500-52106; Systems 12, 2.7W, part #4599-002, catalog 500-52112; Systems 18, 2.7W, part #4599-003, catalog #50-52118; Systems 24, 2.7W, part #4599-004, catalog #500-52124; Systems 30, 2.7W, part #4599-005, catalog #500-52130; Systems 40, 2.7W, part #4599-006, catalog #500-52140; Systems 50, 2.7W, part #4599-007, catalog #500-52150; Systems 06, 3.5W, part #5199-001, catalog 500-54106; Systems 12, 3.5W, part #5199-002, catalog #500-54112; Systems 18, 3.5W, part #5199-003, 500-54118; Systems 24, 3.5W, part #5199-004, catalog #500-54124; Systems 30, 3.5W, part #5199-005, catalog #500-54130; Systems 40, 3.5W, part #5199-005, catalog #500-54140; Systems 50, 3.5W, part #5199-007, catalog #500-54150
FDA Recall
Terminated
·Ekos Corp·Product code KRA·February 9, 2007
The EkoSonic Endovascular System employs high frequency (2-2.5 MHz), low power (0.585 watt average power per transducer) ultrasound to facilitate the delivery of physician-specified fluids in the peripheral vasculature and to deliver solutions into the pulmonary arteries. The EkoSonic Endovascular System is intended for the controlled and selective infusion of physician-specified fluids, including thrombolytics, into the peripheral vasculature and the infusion of solutions into the pulmonary arteries. The reusable EKOS EkoSonic Control Unit provides power to the system and the user interface for operator control. A reusable, non sterile Connector Interface Cable connects the EKOS EkoSonic Control Unit to the EkoSonic Endovascular Device.
FDA Recall
Terminated
·EKOS Corporation·Product code KRA·October 2, 2013