376 results · 10ms · Sources: EU EUDAMED, US FDA

Get notified when this changes

We'll email you when new records match this search — new devices, new clearances, certificate changes, or withdrawals.

Medtronic HawkOne Directional Atherectomy System, Catalog numbers H1-S and H1-S-INT, Small Vessel, 6F (2.2 mm) Recommended sheath, 0.014" (0.36 mm) Compatible guidewire. The HawkOne directional atherectomy system is intended for use in atherectomy of the peripheral vasculature. The HawkOne catheter is indicated for use in conjunction with the SpiderFX embolic protection device in the treatment of severely calcified lesions. The HawkOne catheter is not intended for use in the coronary, carotid, iliac, or renal vasculature.

FDA Enforcement
Class I ·Terminated·ev3 Inc.·January 26, 2022

Arm and Hammer Spinbrush Pro Clean Sonic Tray BJS Made in China. Manufactured for Church and Dwight Co., Inc. Princeton, NJ 08543 USA. For dental health; plaque removal.

FDA Enforcement
Class II ·Terminated·Church & Dwight Inc·August 8, 2012

Offset Femoral Alignment Guide 4mm x 6¿; Product Code: KS 67024 Product Usage: The instrumentation has been designed to facilitate bone preparation and implantation of the Apex Knee or Apex Hip Systems. Product Usage: The instrumentation has been designed to facilitate bone preparation and implantation of the Apex Knee or Apex Hip Systems

FDA Enforcement
Class II ·Terminated·Omnilife Science Inc.·September 2, 2015

.045 X 6 ST Guide Wire, Part number 45-0029-S, Sterile 10 pack of WS-1106ST and has a 6 inch length and 0.045 inch diameter. .054 X 7 ST Guide Wire, Part number 45-0031-S, Sterile 10 Pack of WS-1407ST and has a 7 inch length and 0.054 inch diameter. These guide wires are an orthopedic manual surgical instrument.

FDA Enforcement
Class II ·Terminated·Acumed LLC·March 22, 2017

Nucleic Acid test intended for screening for MRSA/SA. Each kit has 20 tubes. in vitro diagnostic.

FDA Enforcement
Class II ·Terminated·Roche Molecular Systems, Inc.·April 4, 2018

Vascular Solutions Twin-Pass .023" Dual Access Catheter, model 5230. Sterilized with Ethylene Oxide. The Twin-Pass dual access catheter is a dual lumen catheter designed for use in the coronary and/or peripheral vasculature. The Twin-Pass catheter (Models 5200 and 5230) consists of an over-the-wire (OTW) lumen that runs the length of the catheter and a rapid exchange (RX) delivery lumen on the distal segment. The Twin-Pass catheter has a working length of 135cm and is compatible with various guidewire diameters. Model 5200 also has hydrophilic coating on the distal 18cm of the catheter. The Twin-Pass catheter has white positioning marks located at 95cm (single mark) and 105cm (double marks) from the distal tip, respectively. The Twin-Pass catheter has a marker band located 1mm from the distal tip. Model 5200 contains a second marker band located 11mm from the distal tip to identify the distal end of the OTW lumen.

FDA Enforcement
Class I ·Terminated·Vascular Solutions, Inc.·October 26, 2016

Vascular Solutions Twin-Pass Dual Access Catheter, models 5200, 5210, and 5230. Sterilized with Ethylene Oxide. The Twin-Pass dual access catheter is a dual lumen catheter designed for use in the coronary and/or peripheral vasculature. The Twin-Pass catheter (Models 5200 and 5230) consists of an over-the-wire (OTW) lumen that runs the length of the catheter and a rapid exchange (RX) delivery lumen on the distal segment. The Twin-Pass catheter has a working length of 135cm and is compatible with various guidewire diameters. Model 5200 also has hydrophilic coating on the distal 18cm of the catheter. The Twin-Pass catheter has white positioning marks located at 95cm (single mark) and 105cm (double marks) from the distal tip, respectively. The Twin-Pass catheter has a marker band located 1mm from the distal tip. Model 5200 contains a second marker band located 11mm from the distal tip to identify the distal end of the OTW lumen.

FDA Enforcement
Class I ·Terminated·Vascular Solutions, Inc.·October 26, 2016

Vascular Solutions Twin-Pass RX Dual Access Catheter, model 5210. Sterilized with Ethylene Oxide. The Twin-Pass dual access catheter is a dual lumen catheter designed for use in the coronary and/or peripheral vasculature. The Twin-Pass catheter (Models 5200 and 5230) consists of an over-the-wire (OTW) lumen that runs the length of the catheter and a rapid exchange (RX) delivery lumen on the distal segment. The Twin-Pass catheter has a working length of 135cm and is compatible with various guidewire diameters. Model 5200 also has hydrophilic coating on the distal 18cm of the catheter. The Twin-Pass catheter has white positioning marks located at 95cm (single mark) and 105cm (double marks) from the distal tip, respectively. The Twin-Pass catheter has a marker band located 1mm from the distal tip. Model 5200 contains a second marker band located 11mm from the distal tip to identify the distal end of the OTW lumen.

FDA Enforcement
Class I ·Terminated·Vascular Solutions, Inc.·October 26, 2016

50 mm Screw, Item #BG7050 Product Usage: Spinal Solutions distributes a variety of spinal fixation devices in loaner bins or on consignment. The company has decided to provide directions for use and surgical techniques electronically on the companys website. The company has created a label intended to inform the user of the existence of the websites and the information it contains. Indications for use: multiple.

FDA Enforcement
Class II ·Terminated·Spinal Solutions, LLC·June 5, 2013

40 mm Rod, Item #BG1640 Product Usage: Spinal Solutions distributes a variety of spinal fixation devices in loaner bins or on consignment. The company has decided to provide directions for use and surgical techniques electronically on the companys website. The company has created a label intended to inform the user of the existence of the websites and the information it contains. Indications for use: multiple.

FDA Enforcement
Class II ·Terminated·Spinal Solutions, LLC·June 5, 2013

50 mm Rod, Item #BG1650 Product Usage: Spinal Solutions distributes a variety of spinal fixation devices in loaner bins or on consignment. The company has decided to provide directions for use and surgical techniques electronically on the companys website. The company has created a label intended to inform the user of the existence of the websites and the information it contains. Indications for use: multiple.

FDA Enforcement
Class II ·Terminated·Spinal Solutions, LLC·June 5, 2013

Fang Screw 20mm Fang Plate 21mm Product Usage: Spinal Solutions distributes a variety of spinal fixation devices in loaner bins or on consignment. The company has decided to provide directions for use and surgical techniques electronically on the companys website. The company has created a label intended to inform the user of the existence of the websites and the information it contains. Indications for use: multiple.

FDA Enforcement
Class II ·Terminated·Spinal Solutions, LLC·June 5, 2013

45 mm Screw, Item #BG7045 Product Usage: Spinal Solutions distributes a variety of spinal fixation devices in loaner bins or on consignment. The company has decided to provide directions for use and surgical techniques electronically on the companys website. The company has created a label intended to inform the user of the existence of the websites and the information it contains. Indications for use: multiple.

FDA Enforcement
Class II ·Terminated·Spinal Solutions, LLC·June 5, 2013

60 mm Rod, Item #BG1660 Product Usage: Spinal Solutions distributes a variety of spinal fixation devices in loaner bins or on consignment. The company has decided to provide directions for use and surgical techniques electronically on the companys website. The company has created a label intended to inform the user of the existence of the websites and the information it contains. Indications for use: multiple.

FDA Enforcement
Class II ·Terminated·Spinal Solutions, LLC·June 5, 2013

Set Screw, Item #BG3010 Product Usage: Spinal Solutions distributes a variety of spinal fixation devices in loaner bins or on consignment. The company has decided to provide directions for use and surgical techniques electronically on the companys website. The company has created a label intended to inform the user of the existence of the websites and the information it contains. Indications for use: multiple.

FDA Enforcement
Class II ·Terminated·Spinal Solutions, LLC·June 5, 2013

Tenor is a mobile passive lift, intended to be used on horizontal surfaces for lifting and transfer in hospitals, nursing homes or other healthcare facilities. Transfers with the Tenor are made indoors in the patient's room, in communal areas or in a bathroom. Tenor is meant to be used with the patient type who: sits in a wheelchair, has no capability to support themselves at all, cannot stand unsupported and is not able to bear weight (not even partially), is dependent on caregiver in most situations, is a passive resident, might be almost completely bed ridden, is often stiff and has contracted joints, and/or is totally dependent. The Tenor has a safe working load of 320 KG (705 lbs).

FDA Enforcement
Class II ·Terminated·ARJOHUNTLEIGH POLSKA SP. ZO.O.·September 24, 2014

XiO RTP System. Used to create treatment plans for any cancer patient for whom external beam radiation therapy or brachytherapy has been prescribed.

FDA Enforcement
Class II ·Terminated·Elekta, Inc.·February 12, 2014

Mammotome Revolve Dual Vacuum Assist Biopsy System The device is used to sample breast tissue that has been identified as suspicious under imaging guidance

FDA Enforcement
Class II ·Terminated·Devicor Medical Products Inc·March 29, 2017

CORE¿ Trumpet Handpiece only, Catalog Number CD8450 The CORE Trumpet (CD81XX, CD83XX, and CD84XX) has applications in gynecological laparoscopy, laparoscopic cholecystectomy and other laparoscopic procedures

FDA Enforcement
Class II ·Terminated·ConMed Corporation·October 26, 2016

XiO Radiation Treatment Planning System. Used to create treatment plans for any cancer patient for whom external beam radiation therapy or brachytherapy has been prescribed.

FDA Enforcement
Class II ·Terminated·Elekta, Inc.·October 28, 2015