Alere Cholestech LDX Calibration Verification, 4 vial set, Catalog Number: 88770 Alere Cholestech LDX Calibration Verification (hereafter referred to as CAL VERS) enables users to monitor the performance of total cholesterol (TC), high density lipoprotein cholesterol (HDL), triglycerides (TRG), and glucose (GLU) test procedures on the Alere Cholestech LDX System. Calibration verification is optional for CLIA waived systems, such as the Alere Cholestech LDX System, under CLIA regulations. However local or state regulations may require that calibration verification is run at regular intervals.

FDA Enforcement
Class III ·Terminated·Alere San Diego, Inc.·February 6, 2013

Alere Cholestech LDX Multianalyte Control, 2 vial set, Catalog Number: 88769 Alere Cholestech LDX Multianalyte Control (hereafter referred to as Controls) enables users to monitor the performance of total cholesterol (TC), high density lipoprotein cholesterol (HDL), triglycerides (TRG), glucose (GLU), alanine aminotransferase (ALT), and aspartate aminotransferase (AST) test procedures on the Alere Cholestech LDX System. The results obtained for the controls are to be compared with the assigned values given on the Expected Values Card, accompanying the package insert, to determine if the procedure is within control limits. Assayed quality control material for use with the Alere Cholestech LDX System.

FDA Enforcement
Class III ·Terminated·Alere San Diego, Inc.·February 6, 2013

LDX Optical Check Cassettes (OCC) Model Number: 10-228 and 14-535 Cassette in box with foam insert. The cassette is used to check the optics system of the LDX analyzer. Product Usage: The Optics Check Cassette is used to check the optics system of the Alere Cholestech LDX¿ Analyzer. It is run once a day before patient samples are tested and after the analyzer has been moved or serviced.

FDA Enforcement
Class III ·Terminated·Alere San Diego, Inc.·September 21, 2016

Product Brand Name(s): Alere Cholestech LDX¿ Lipid Profile"GLU Test Cassette, Model 10-991. Product Generic Name: Alere Cholestech LDX¿ Lipid Profile"GLU Test Cassette. Description of the product: Lipid. Glucose panel Test cassettes. Product packaging: 10 individually pouched cassettes in a labeled kit box. Intended for the quantitative determination of total cholesterol, HDL (high-density lipoprotein) cholesterol, triglycerides, and/or glucose in whole blood, serum, and plasma.

FDA Enforcement
Class III ·Terminated·Alere San Diego, Inc.·December 4, 2013

Alere Cholestech LDX Multianalyte Controls, PN 88769 and 88773. Enables users to monitor the performance of total cholesterol (TC), high density lipoprotein cholesterol (HDL), triglycerides (TRG) and glucose (GLU) test procedures.

FDA Enforcement
Class III ·Terminated·Alere San Diego, Inc.·October 21, 2015