GE Healthcare Giraffe Incubator Carestation CS1, Infant Incubator. Model Numbers: 1) 2082844-002-01040417; 2) 2082844-002-01044956; 3) 2082844-002-01058424; 4) 2082844-002-01069017; 5) 2082844-002-01089666; 6) 2082844-002-01090474; 7) 2082844-002-01091269; 8) 2082844-002-01093489; 9) 2082844-002-01113262; 10) 2082844-002-01113711; 11) 2082844-002-01123085; 12) 2082844-002-01123918; 13) 2082844-002-01128966; 14) 2082844-002-01133042; 15) 2082844-002-01146447; 16) 2082844-002-100205; 17) 2082844-002-100749; 18) 2082844-002-100752; 19) 2082844-002-100995; 20) 2082844-002-101425; 21) 2082844-002-523548; 22) 2082844-002-529928; 23) 2082844-002-594800; 24) 2082844-002-643544; 25) 2082844-002-925841; 26) 2082844-002-965540; 27) 2082844-002-982916; 28) 2082844-002-983420; 29) 2082844-002-993905; 30) 2082844-002-995018; 31) 2082844-002-995799; 32) 2082844-002-998943; Radiant infant warmer

FDA Recall
Completed ·DATEX--OHMEDA, INC.·Product code FMZ·June 6, 2023

Draeger Globe Trotter IC, Catalog Number: MU20509, Draeger Medical, Inc., Telford, PA 18969

FDA Recall
Terminated ·Draeger Medical, Inc.·Product code FMZ·January 31, 2008

Giraffe Shuttle. Upgrade Kits with part number 2109672-001 and 2109673-001 GTIN: 00840682110808.

FDA Recall
Terminated ·GE Healthcare, LLC·Product code FMZ·April 2, 2020

CarePlus Incubator Ohmeda-Ohio CarePlus Incubator- Incubators provide a controlled thermal environment for neonates who are unable to provide their own thermoregulation. They may also be used for short periods of time to facilitate the neonate s transition from the uterus to the external environment. Most Incubators provide a controlled thermal environment for neonates who are unable to provide their own thermoregulation. They may also be used for short periods of time to facilitate the neonate s transition from the uterus to the external environment. Most incubators can be used in two operating modes: 1. Air Control: The clinician sets the appropriate air temperature for maintaining the desired patient temperature. The air temperature is initially selected based on the clinician s training and experience and then is adjusted based on the patient s needs and clinical status. 2. Patient control: The clinician sets the desired patient temperature. A skin temperature probe sense the patient temperature and feeds this information to the controller of the incubator. Thecontroller then adjusts the heater output to maintain the patient temperature at the set value. These adjustments to the heater output are made in such a way to gradually change the patient s temperature while minimizing overshooting and patient stress. Incubators have alarms to alert clinicians when certain patient or equipment conditions occur, such as a malfunction, or an excessive departure of the patient s temperature from the set value. Incubators may incorporate other features, such as humidification of the infant environment, tilting of the bed, oxygen supply, and data output to remote monitors or nurse call systems

FDA Recall
Terminated ·Ohmeda Medical·Product code FMZ·November 18, 2016

GE Healthcare neonatal incubator, models: a) Lullaby Incubator, b) Lullaby Incubator XP, c) Lullaby Incubator TR

FDA Recall
Open, Classified ·Wipro GE Healthcare Private Ltd. 122 Part 1 Odyssey And Galileo Bengaluru India·Product code FMZ·December 26, 2023

Dual Incu i (Atom Infant Incubator Model 100) Atom Medical Corporation 3-18-15 Hongo, Bunkyo-Ku, Tokyo, Japan 113-0033 Usage: A combination incubator and warmer for infants.

FDA Recall
Terminated ·Atom Medical Corporation 3-18-15 Hongo Bunkyo-Ku Japan·Product code FMZ·August 23, 2011

Draeger GT500. GlobeTrotter Transport System. Catalog Number: MU20508, Draeger Medical, Inc., Telford, PA 18969

FDA Recall
Terminated ·Draeger Medical, Inc.·Product code FMZ·January 31, 2008

Datascope/ Maquet IABPs. System 98/98XT Intra-Aortic Balloon Pump; CS100/CS100i Intra-Aortic Balloon Pump; CS300 Intra-Aortic Balloon Pump; Manufactured by Datascope Corp., 1300 MacArthur Blvd., Mahwah, NJ 07430 The Intra-Aortic Balloon Pump (IABP) is an electromechanical system used to inflate and deflate intra-aortic balloon. It provides temporary support to the left ventricle via the principle of counterpulsion. The IABP is placed in the descending aorta, via the principe of counterpulsation. The IABP is placed in the descending aorta, just distal to the left subclavian artery. Once the balloon is positioned, the IABP is adjusted to trigger in synchrony with the ECG or arterial pressure waveform to ensure that inflation and deflation occur at the appropriate points during the cardiac cycle. The CS300 has the additional capability to automatically calibrate a fiber-optic pressure sensor placed in the tip of the intra-aortic balloon. The IABP will recalibrate every 2 hours or sooner should the patient or environmental conditions change. The target populations are adult and pediatric. The IABP is intended for use in the health care facility setting.

FDA Recall
Terminated ·Maquet Datascope Corp Cardiac Assist Division·Product code FMZ·March 16, 2011

Incu i (Atom Infant Incubator Model 101) Atom Medical Corporation 3-18-15 Hongo, Bunkyo-Ku, Tokyo, Japan 113-0033 Usage: An incubator for infants.

FDA Recall
Terminated ·Atom Medical Corporation 3-18-15 Hongo Bunkyo-Ku Japan·Product code FMZ·August 23, 2011

GE Healthcare neonatal incubator, models: a) Care Plus, b) Care Plus 1000, c) Care Plus 2000, d) Care Plus 3000, e) Care Plus 4000, Plus 4000

FDA Recall
Open, Classified ·Wipro GE Healthcare Private Ltd. 122 Part 1 Odyssey And Galileo Bengaluru India·Product code FMZ·December 26, 2023

Giraffe OmniBed Ohmeda Medical Omnibed- The OmniBed is a combination of an infant incubator ( incubator ) and an infant radiant warmer ( warmer ). Incubators and warmers provide heat in a controlled manner to neonates who are unable to thermo-regulate based on their own physiology. Incubators provide an enclosed, temperature controlled environment and warmers provide infrared heat in an open environment. They may also be used for short periods of time to facilitate the neonate s transition from the uterus to the external environment

FDA Recall
Terminated ·Ohmeda Medical·Product code FMZ·November 18, 2016

Temperature Sensing 100% Silicone Foley Catheter, Part Number 102203101463DO - Product Usage: is a 3 lumen silicone catheter with a sensor to measure temperature while draining the urinary bladder.

FDA Recall
Terminated ·Degania Medical Devices Pvt. Ltd. Plot No 251 Imt Manesar Gurgaon India·Product code EZL·March 17, 2020

Temperature Sensing 100% Silicone Foley Catheter, Part Number 102201101663MD - Product Usage: is a 3 lumen silicone catheter with a sensor to measure temperature while draining the urinary bladder.

FDA Recall
Terminated ·Degania Medical Devices Pvt. Ltd. Plot No 251 Imt Manesar Gurgaon India·Product code EZL·March 17, 2020

Temperature Sensing 100% Silicone Foley Catheter, Part Number 102201101863MD - Product Usage: is a 3 lumen silicone catheter with a sensor to measure temperature while draining the urinary bladder.

FDA Recall
Terminated ·Degania Medical Devices Pvt. Ltd. Plot No 251 Imt Manesar Gurgaon India·Product code EZL·March 17, 2020

Temperature Sensing 100% Silicone Foley Catheter, Part Number 102203101863DO - Product Usage: is a 3 lumen silicone catheter with a sensor to measure temperature while draining the urinary bladder.

FDA Recall
Terminated ·Degania Medical Devices Pvt. Ltd. Plot No 251 Imt Manesar Gurgaon India·Product code EZL·March 17, 2020

Temperature Sensing 100% Silicone Foley Catheter, Part Number 102201100880MD - Product Usage: is a 3 lumen silicone catheter with a sensor to measure temperature while draining the urinary bladder.

FDA Recall
Terminated ·Degania Medical Devices Pvt. Ltd. Plot No 251 Imt Manesar Gurgaon India·Product code EZL·March 17, 2020

Temperature Sensing 100% Silicone Foley Catheter, Part Number 102201101463MD - Product Usage: is a 3 lumen silicone catheter with a sensor to measure temperature while draining the urinary bladder.

FDA Recall
Terminated ·Degania Medical Devices Pvt. Ltd. Plot No 251 Imt Manesar Gurgaon India·Product code EZL·March 17, 2020

Temperature Sensing 100% Silicone Foley Catheter, Part Number 102203101663DO - Product Usage: is a 3 lumen silicone catheter with a sensor to measure temperature while draining the urinary bladder.

FDA Recall
Terminated ·Degania Medical Devices Pvt. Ltd. Plot No 251 Imt Manesar Gurgaon India·Product code EZL·March 17, 2020

Temperature Sensing 100% Silicone Foley Catheter, Part Number 102201101063MD - Product Usage: is a 3 lumen silicone catheter with a sensor to measure temperature while draining the urinary bladder.

FDA Recall
Terminated ·Degania Medical Devices Pvt. Ltd. Plot No 251 Imt Manesar Gurgaon India·Product code EZL·March 17, 2020

Temperature Sensing 100% Silicone Foley Catheter, Part Number 102202101663DO - Product Usage: is a 3 lumen silicone catheter with a sensor to measure temperature while draining the urinary bladder.

FDA Recall
Terminated ·Degania Medical Devices Pvt. Ltd. Plot No 251 Imt Manesar Gurgaon India·Product code EZL·March 17, 2020