SERIES A PATELLA
Report
- Report Number
- 0001825034-2018-02146
- Event Type
- Injury
- Date Received
- March 22, 2018
- Date of Event
- February 21, 2018
- Report Date
- April 20, 2018
- Manufacturer
- ZIMMER BIOMET, INC.
- Product Code
- JWH
- PMA / PMN Number
- PK171054
- Removal / Correction Number
- N/A
- Adverse Event
- Yes
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- NM, US
- Reporter Occupation
- PHYSICIAN
Narratives
THIS FOLLOW-UP REPORT IS BEING SUBMITTED TO RELAY ADDITIONAL INFORMATION. CONCOMITANT MEDICAL PRODUCTS: EP-183660 E1 VNGD PS TIB BRG 79/83X10 173580; 00111214001 PALACOS R 1X40 SINGLE 81454445; 00111314001 PALACOS RG 1X40 SINGLE 81824426; 183132 VAN PS OPEN INTL FEM-LT 70 J3655102. REPORTED EVENT WAS CONFIRMED BY REVIEW OF THE PROVIDED X-RAYS AND OP NOTES. REVIEW OF PRE-REVISION FOLLOW-UP RECORDS NOTED PATIENT EXPERIENCING PAIN WITH ACTIVITIES AND INSTABILITY. DISLOCATION OF THE PATELLA AND ALSO NOTED THAT THERE IS NO GROSS MALROTATION ON THE FEMORAL SIDE BUT THERE MIGHT BE INTERNAL ROTATION ON THE TIBIAL SIDE. X-RAYS PROVIDED WERE SENT TO HCP FOR REVIEW. IT WAS NOTED THAT THE PATELLAR COMPONENT WHICH DEMONSTRATED SEVERE LATERAL SUBLUXATION VERSUS DISLOCATION. DHR WAS REVIEWED AND NO DISCREPANCIES RELEVANT TO THE REPORTED EVENT WERE FOUND. REVIEW OF THE COMPLAINT HISTORY DETERMINED THAT NO FURTHER ACTION IS REQUIRED. ROOT CAUSE WAS UNABLE TO BE DETERMINED AS THE NECESSARY INFORMATION TO ADEQUATELY INVESTIGATE THE REPORTED EVENT WAS NOT PROVIDED. IF ANY FURTHER INFORMATION IS FOUND WHICH WOULD CHANGE OR ALTER ANY CONCLUSIONS OR INFORMATION, A SUPPLEMENTAL WILL BE FILED ACCORDINGLY. ZIMMER BIOMET WILL CONTINUE TO MONITOR FOR TRENDS.
(B)(4). CONCOMITANT MEDICAL PRODUCTS: BIOMET CRUCIATE TIBIAL TRAY, CATALOG #: 141235, LOT #: J3646481, VANGUARD POSTERIOR STABILIZED BEARING, CATALOG #: EP-183660, LOT #: 173580, VANGUARD INTERLOCK FEMORAL, CATALOG #: 183132, LOT #: J3655102. CUSTOMER HAS INDICATED THAT THE PRODUCT WILL NOT BE RETURNED TO ZIMMER BIOMET FOR INVESTIGATION, AS PRODUCT LOCATION IS UNKNOWN. THE INVESTIGATION IS IN PROCESS. ONCE THE INVESTIGATION HAS BEEN COMPLETED, A FOLLOW-UP MDR WILL BE SUBMITTED. IF ANY FURTHER INFORMATION IS FOUND WHICH WOULD CHANGE OR ALTER ANY CONCLUSIONS OR INFORMATION, A SUPPLEMENTAL WILL BE FILED ACCORDINGLY. ZIMMER BIOMET WILL CONTINUE TO MONITOR FOR TRENDS. MULTIPLE MDR REPORTS WERE FILED FOR THIS EVENT, PLEASE SEE ASSOCIATED REPORTS: 0001825034-2018-02045. PRODUCT LOCATION UNKNOWN.
IT WAS REPORTED THAT THE PATIENT UNDERWENT A LEFT KNEE ARTHROPLASTY. SUBSEQUENTLY, THE PATIENT WAS REVISED DUE TO MALPOSITION OF TIBIAL PROSTHESIS AND DISLOCATION OF PATELLA.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 206684 | SERIES A PATELLA | PROSTHESIS, KNEE | JWH | ZIMMER BIOMET, INC. | N/A | 056770 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 67 YR | Hospitalization| R |