Tool · Post-Market Surveillance

PSUR Report

The vigilance database section of your PSUR, generated in seconds: FDA MAUDE adverse event trends, recalls, and enforcement classifications for your device and similar devices — with the documented, reproducible methodology auditors ask for.

Period
from
to
Leave empty for the last 24 months

Reporting period 2024-072026-06 · FDA data refreshed ~monthly

Product Code: JWH FDA class 2

Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer

View full classification →
Adverse events in period
18,179
0% vs. prior period (18,134)
Deaths reported
5
Recalls in period
25
Class I enforcement
0

Adverse events per month

2024-07 – 2026-06
Loading...

Events by type

Period vs. prior period
Loading...
Event type
Period
Prior
Death
5
19
Injury
16,544
15,035
Malfunction
1,625
3,076
Other
5
4

Most reported coded problems

Top 15
Product problems
Count
Adverse Event Without Identified Device or Use Problem
8,496
Naturally Worn
2,331
Loosening of Implant Not Related to Bone-Ingrowth
2,303
Fracture
1,249
Unstable
1,050
Loss of or Failure to Bond
832
Insufficient Device Problem Information
731
Device Appears to Trigger Rejection
442
Detachment of Device or Device Component
344
Device Dislodged or Dislocated
306
Patient-Device Incompatibility
271
Migration
183
Difficult to Insert
180
Mechanical Problem
168
Osseointegration Problem
126
Patient problems
Count
Pain
4,913
Joint Laxity
3,305
Insufficient Information
2,680
Unspecified Infection
2,679
Osteolysis
1,865
No Clinical Signs, Symptoms or Conditions
1,657
Swelling/ Edema
1,584
Failure of Implant
1,484
Synovitis
1,237
Ambulation or Postural Difficulties
1,162
Loss of Range of Motion
1,006
Discomfort
866
Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available
857
Implant Pain
774
Aseptic loosening
702

Recalls in period

25 total
FDA enforcement classification: Class II: 28
Date
Recalling firm
Status
2026-01-15
Open, Classified
2026-01-05
Open, Classified
2025-07-31
Open, Classified
2025-07-09
Open, Classified
2025-07-09
Open, Classified
2025-06-02
Open, Classified
2025-06-02
Open, Classified
2025-05-23
Open, Classified
2025-04-03
Open, Classified
2025-04-03
Open, Classified
2025-04-03
Open, Classified
2025-04-03
Open, Classified
2025-02-27
Open, Classified
2025-02-14
Open, Classified
2025-02-14
Open, Classified
2025-02-14
Open, Classified
2025-01-06
Open, Classified
2025-01-06
Open, Classified
2024-12-18
Open, Classified
2024-12-10
Open, Classified
2024-10-02
Open, Classified
2024-10-02
Open, Classified
2024-10-02
Open, Classified
2024-10-02
Open, Classified
2024-09-04
Open, Classified

Adverse events by year

Loading...

Methodology & data provenance

For your PSUR appendix

Search protocol: FDA MAUDE adverse event reports, FDA device recalls, and FDA enforcement reports (openFDA datasets) were queried for product code JWH, reporting period 2024-07 to 2026-06 (prior comparison period 2022-07 to 2024-06).

Data coverage: adverse event data for these product codes extends through 2026-05. Source openFDA export dated 2026-06-30. Recall records with missing or implausible initiation dates (1 for these codes) are excluded from period counts.

Generated: 2026-07-05 23:23 UTC by BEUDAMED (beudamed.com/fda/psur-report). Dataset sizes: 25,039,198 adverse events, 58,607 recalls, 39,365 enforcement reports.

PSUR database searches, explained

Under the EU MDR, manufacturers must produce a Periodic Safety Update Report (PSUR) (Class IIa and above; a PMS report for Class I) on a defined schedule. A required part of that report is a survey of publicly available vigilance data — most importantly the FDA's MAUDE adverse event database and FDA recall records — covering both your own device and similar devices on the market (the "state of the art").

Doing this by hand means repeated MAUDE queries, manual export, deduplication, and trending — hours of work per report, repeated every reporting period. This tool runs the same search protocol in seconds and documents it: which datasets were queried, with which filters, when, and with what coverage — so the search is reproducible, which is exactly what a Notified Body auditor wants to see.

Event counts are grouped by the FDA's reported event type (death, injury, malfunction). Name-based device matching is clearly labeled as indicative: only you can confirm whether a specific MAUDE report concerns your device. Recall records with implausible dates are excluded and the exclusion is disclosed. All data is from the official openFDA datasets and refreshed approximately monthly.