FDA Adverse Event Injury Summary report: N

COBE SPECTRA BLOOD COLLECTION

MDR report key: 5564170 · Received April 8, 2016

Report

Report Number
1722028-2016-00236
Event Type
Injury
Date Received
April 8, 2016
Date of Event
November 5, 2015
Report Date
April 8, 2016
Manufacturer
TERUMO BCT
Product Code
GKT
PMA / PMN Number
BK080035
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
IN
Reporter Occupation
HEALTH PROFESSIONAL

Narratives

Additional Manufacturer Narrative · 1

INVESTIGATION IS IN PROCESS. A FOLLOW-UP REPORT WILL BE PROVIDED.

Additional Manufacturer Narrative · 1

INVESTIGATION: FURTHER EVALUATION OF THIS EVENT HAS DETERMINED THAT THE DEVICE DID NOT CAUSE OR CONTRIBUTE TO A DEATH OR SERIOUS INJURY BASED ON ADDITIONAL INVESTIGATIONAL INFORMATION. THE PHYSICIAN IN CHARGE, AND CO-AUTHOR OF THE STUDY, CONFIRMED THAT THERE WAS NO MEDICAL INTERVENTION REQUIRED FOR THE PATIENT REACTION. ACCORDING TO THE AABB THERAPEUTIC APHERESIS: A PHYSICIANS HANDBOOK, THE RATE OF ADVERSE EVENTS DURING THERAPEUTIC APHERESIS IS 4-5%.A SPECIFIC DEVICE HISTORY RECORD REVIEW COULD NOT BE PERFORMED DUE TO LACK OF LOT INFORMATION,HOWEVER, ALL LOTS MUST MEET ACCEPTANCE CRITERIA FOR RELEASE. ROOT CAUSE: THE DISPOSABLE SET WAS UNAVAILABLE FOR RETURN. THE STUDY ACKNOWLEDGES THAT THE PATIENT REACTION WAS DUE TO CITRATE TOXICITY AND UNDERSTANDS THIS IS A FREQUENT COMPLICATION OF APHERESIS PROCEDURES.

Description of Event or Problem · 1

AN ARTICLE IN 'TRANSFUSION AND APHERESIS SCIENCE', NOVEMBER 2015, DOCUMENTED A RETROSPECTIVE ANALYSIS OF PERIPHERAL BLOOD STEM CELL (PBSC) COLLECTIONS PERFORMED MARCH 2010 - DECEMBER 2013. OF THE COLLECTIONS THAT WERE ANALYZED, THERE WERE 63 OCCURRENCES OF PATIENTS SUFFERING FROM HYPOCALCEMIA DURING THE PBSC COLLECTIONS ON COBE SPECTRA. THE SYMPTOMS INCLUDED PERIORAL PARESTHESIA FOLLOWED BY DIGITAL NUMBNESS. IT IS NOT KNOWN AT THIS TIME IF MEDICAL INTERVENTION WAS REQUIRED FOR THE PATIENT REACTIONS. FORTY OF THE 63 PATIENTS HAD BEEN INJECTED WITH A 5-10ML BOLUS OF 10% CALCIUM GLUCONATE DURING THE PROCEDURE AS PART OF THE STUDY. TWENTY THREE OF THE 63 PATIENTS HAD CONTINUOUS 10% CALCIUM GLUCONATE INFUSED DURING THE PROCEDURE AS PART OF THE STUDY. PATIENT INFORMATION IS NOT AVAILABLE AT THIS TIME. THIS REPORT IS BEING FILED FOR ONE OF THE 63 PATIENTS. EXACT DETAILS OF EACH PATIENT REACTION ARE NOT AVAILABLE AT THIS TIME. THE DISPOSABLE SET IS NOT AVAILABLE FOR RETURN BECAUSE IT WAS DISCARDED BY THE CUSTOMER. THE TITLE OF THE ARTICLE IS 'PROPHYLACTIC LOW DOSE CONTINUOUS CALCIUM INFUSION DURING PERIPHERAL BLOOD STEM CELL (PBSC) COLLECTIONS TO REDUCE CITRATE RELATED TOXICITY.'

Description of Event or Problem · 1

PER THE CUSTOMER, NO MEDICAL INTERVENTION WAS REQUIRED FOR THIS EVENT.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
220854 COBE SPECTRA BLOOD COLLECTION COBE SPECTRA AUTOPBSC SET GKT TERUMO BCT

Patients

Seq Age Sex Outcome Treatment
1 Other