Tool · Post-Market Surveillance

PSUR Report

The vigilance database section of your PSUR, generated in seconds: FDA MAUDE adverse event trends, recalls, and enforcement classifications for your device and similar devices — with the documented, reproducible methodology auditors ask for.

Period
from
to
Leave empty for the last 24 months

Reporting period 2024-072026-06 · FDA data refreshed ~monthly

Product Code: GKT FDA class 2

Separator, Automated, Blood Cell, Diagnostic

View full classification →
Adverse events in period
521
-32% vs. prior period (767)
Deaths reported
30
Recalls in period
0
Class I enforcement
0

Adverse events per month

2024-07 – 2026-06
Loading...

Events by type

Period vs. prior period
Loading...
Event type
Period
Prior
Death
30
43
Injury
40
83
Malfunction
451
641

Most reported coded problems

Top 15
Product problems
Count
Insufficient Device Problem Information
460
Adverse Event Without Identified Device or Use Problem
293
No Apparent Adverse Event
97
Use of Device Problem
62
Device Handling Problem
58
Device Slipped
20
Mechanical Problem
18
Defective Component
3
Appropriate Device Problem Term/Code Not Available
3
Patient Device Interaction Problem
2
Microbial Contamination of Device
2
Leak/Splash
2
Infusion or Flow Problem
2
Improper or Incorrect Procedure or Method
2
Therapeutic or Diagnostic Output Failure
1
Patient problems
Count
No Clinical Signs, Symptoms or Conditions
447
Hemolysis
22
Insufficient Information
21
Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available
14
Nausea
8
Loss of consciousness
7
Fever
7
Chills
7
Vomiting
6
Low Blood Pressure/ Hypotension
6
Air Embolism
6
Syncope/Fainting
5
Swelling/ Edema
3
Hypovolemia
3
Hematuria
3

Recalls in period

0 total

No recalls recorded for these product codes in the reporting period.

Adverse events by year

Loading...

Methodology & data provenance

For your PSUR appendix

Search protocol: FDA MAUDE adverse event reports, FDA device recalls, and FDA enforcement reports (openFDA datasets) were queried for product code GKT, reporting period 2024-07 to 2026-06 (prior comparison period 2022-07 to 2024-06).

Data coverage: adverse event data for these product codes extends through 2026-05. Source openFDA export dated 2026-06-30. Recall records with missing or implausible initiation dates (0 for these codes) are excluded from period counts.

Generated: 2026-07-05 23:03 UTC by BEUDAMED (beudamed.com/fda/psur-report). Dataset sizes: 25,039,198 adverse events, 58,607 recalls, 39,365 enforcement reports.

PSUR database searches, explained

Under the EU MDR, manufacturers must produce a Periodic Safety Update Report (PSUR) (Class IIa and above; a PMS report for Class I) on a defined schedule. A required part of that report is a survey of publicly available vigilance data — most importantly the FDA's MAUDE adverse event database and FDA recall records — covering both your own device and similar devices on the market (the "state of the art").

Doing this by hand means repeated MAUDE queries, manual export, deduplication, and trending — hours of work per report, repeated every reporting period. This tool runs the same search protocol in seconds and documents it: which datasets were queried, with which filters, when, and with what coverage — so the search is reproducible, which is exactly what a Notified Body auditor wants to see.

Event counts are grouped by the FDA's reported event type (death, injury, malfunction). Name-based device matching is clearly labeled as indicative: only you can confirm whether a specific MAUDE report concerns your device. Recall records with implausible dates are excluded and the exclusion is disclosed. All data is from the official openFDA datasets and refreshed approximately monthly.