LOGIC FEMORAL PS CEM LEFT SZ 3
Report
- Report Number
- 1038671-2024-02912
- Event Type
- Injury
- Date Received
- August 21, 2024
- Date of Event
- July 29, 2024
- Report Date
- April 10, 2025
- Manufacturer
- EXACTECH, INC.
- Product Code
- JWH
- UDI-DI
- 10885862001146
- PMA / PMN Number
- K033883
- Adverse Event
- Yes
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- NY, US
- Reporter Occupation
- PHYSICIAN
- Health Professional
- Yes
Narratives
THE REASON FOR THE REVISION REPORTED CANNOT BE CONFIRMED FROM THE INFORMATION PROVIDED BUT MAY BE THE RESULT OF PROSTHESIS WEAR, INSTABILITY, DEVICE-DEVICE LOOSENING, FAILURE OF THE CEMENT USED TO SECURE THE FEMORAL COMPONENT TO THE FEMORAL BONE, WHICH LED TO LOOSENING AT THE CEMENT-IMPLANT INTERFACE, AND PATELLAR LOOSENING OR DUE TO INCLUSION OF THE POLYETHYLENE IN THE PACKAGING RECALL. ADDITIONALLY, THESE DEVICES APPEAR TO HAVE BEEN IMPLANTED FOR OVER TEN YEARS PRIOR TO THE REPORTED EVENT. POTENTIAL CONTRIBUTIONS OF USER AND PATIENT-RELATED CONSIDERATIONS TO THE EVENT COULD NOT BE ASSESSED AS THE DEVICES WERE NOT AVAILABLE FOR EVALUATION AND IMAGES AND RADIOGRAPHS WERE NOT PROVIDED. H6: CORRECTED HEALTH EFFECT, MEDICAL DEVICE, COMPONENT, AND INVESTIGATION CLINICAL CODES.
D10: CONCOMITANT DEVICES: 2046556 02-012-35-3013 - LOGIC TIBIA PS MOD INSRT SZ 3 13MM 02-012-41-3032 OR 3033 - LOGIC TIBIA TRAPTRAY CEM SZ 3F/2T 200-02-35 OR 38 - THREE PEG PATELLA 35MM OR 38 MM THE DEVICE WAS NOT RETURNED FOR EVALUATION AND NO MEDICAL OR OTHER RECORDS CONTAINING TREATMENT INFORMATION OR PATIENT INFORMATION HAVE BEEN RECEIVED; THEREFORE, THE REPORTED EVENT CANNOT BE CONFIRMED, NOR CAN THE CIRCUMSTANCES OR POTENTIAL CAUSES OR CONTRIBUTORS TO THE ALLEGED EVENT BE EVALUATED. SHOULD ADDITIONAL, MATERIAL INFORMATION BECOME AVAILABLE THAT PERMITS MORE ANALYSIS OR CONCLUSIONS, A SUPPLEMENTAL REPORT WILL BE FILED ACCORDINGLY.
IT WAS REPORTED THAT APPROXIMATELY 150 MONTHS AFTER A LEFT TOTAL KNEE REPLACEMENT PROCEDURE, THE PATIENT UNDERWENT A REVISION PROCEDURE TO ADDRESS PROSTHESIS WEAR, OSTEOLYSIS, SYNOVITIS, LOOSENING, DEBONDING, AORI TYPE 2B BONE LOSS. REVISION SURGERY OPERATIVE NOTES WERE PROVIDED. PATIENT LEFT THE OPERATING ROOM IN STABLE CONDITION. POST OPERATIVE DIAGNOSIS NOTED WEAR OF THE IMPLANT. NO FURTHER ISSUES OR COMPLICATIONS WERE REPORTED. NO ADDITIONAL INFORMATION IS AVAILABLE.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 2362499 | LOGIC FEMORAL PS CEM LEFT SZ 3 | PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL | JWH | EXACTECH, INC. | 10885862001146 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | NA | Unknown | Hospitalization| R | SEE H11 |