FDA Adverse Event Injury Summary report: N

LOGIC CR TIB INSERT SLOPE++, SZ 4, 11MM

MDR report key: 19920876 · Received August 6, 2024

Report

Report Number
1038671-2024-02707
Event Type
Injury
Date Received
August 6, 2024
Date of Event
December 2, 2022
Report Date
November 25, 2024
Manufacturer
EXACTECH, INC.
Product Code
JWH
UDI-DI
10885862174529
PMA / PMN Number
K111400
Adverse Event
Yes
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
FL, US
Reporter Occupation
003

Narratives

Additional Manufacturer Narrative · 0

CONCOMITANT DEVICES: 2110632 02-010-03-0340 - LOGIC CR FEMORAL CEM, RIGHT, SZ 4. 2921767 02-012-45-4040 - LGC TIBIAL FIT TRAY CEM SZ 4F/4T. 2990773 200-02-38 - THREE PEG PATELLA 38MM. 2W507 203-96-21 - (11-2714) STRYKER 2000 90X13/21X 1.9MM. THE DEVICE WAS NOT RETURNED FOR EVALUATION AND NO MEDICAL OR OTHER RECORDS CONTAINING TREATMENT INFORMATION OR PATIENT INFORMATION HAVE BEEN RECEIVED; THEREFORE, THE REPORTED EVENT CANNOT BE CONFIRMED, NOR CAN THE CIRCUMSTANCES OR POTENTIAL CAUSES OR CONTRIBUTORS TO THE ALLEGED EVENT BE EVALUATED. SHOULD ADDITIONAL, MATERIAL INFORMATION BECOME AVAILABLE THAT PERMITS MORE ANALYSIS OR CONCLUSIONS, A SUPPLEMENTAL REPORT WILL BE FILED ACCORDINGLY.

Additional Manufacturer Narrative · 0

REPORT NUMBERS: 1038671-2024-02719 THIS FOLLOW-UP REPORT IS BEING SUBMITTED TO RELAY ADDITIONAL AND/OR CORRECTED INFORMATION. THE REASON FOR THE REVISION REPORTED CANNOT BE CONFIRMED FROM THE INFORMATION PROVIDED BUT MAY BE THE RESULT OF PROSTHESIS WEAR, FEMORAL LOOSENING, AND TIBIAL LOOSENING OR DUE TO INCLUSION OF THE POLYETHYLENE IN THE PACKAGING RECALL. POTENTIAL CONTRIBUTIONS OF USER AND PATIENT-RELATED CONSIDERATIONS TO THE EVENT COULD NOT BE ASSESSED AS THE DEVICES WERE NOT AVAILABLE FOR EVALUATION AND IMAGES AND RADIOGRAPHS WERE NOT PROVIDED. IF ANY FURTHER INFORMATION IS OBTAINED THAT WOULD CHANGE OR ALTER ANY INFORMATION PROVIDED, A SUPPLEMENTAL REPORT WILL BE FILED ACCORDINGLY.

Description of Event or Problem · 0

IT WAS REPORTED VIA LEGAL DOCUMENTATION THAT APPROXIMATELY 101 MONTHS AFTER A RIGHT TOTAL KNEE REPLACEMENT PROCEDURE, THE PATIENT UNDERWENT A REVISION PROCEDURE TO ADDRESS PROSTHESIS WEAR, OSTEOLYSIS, ASEPTIC LOOSENING AND DEBONDING OF THE FEMORAL COMPONENT, DAILY KNEE PAIN AND DISCOMFORT, LIMITED DAILY ACTIVITIES AND IMPACTED QUALITY OF LIFE. POST OPERATIVE DIAGNOSIS NOTED WEAR OF THE IMPLANT. NO FURTHER ISSUES OR COMPLICATIONS WERE REPORTED. NO ADDITIONAL INFORMATION IS AVAILABLE.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1635800 LOGIC CR TIB INSERT SLOPE++, SZ 4, 11MM PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL JWH EXACTECH, INC. 10885862174529

Patients

Seq Age Sex Outcome Treatment
1 69 YR Male Required Intervention| H