FDA Adverse Event Injury Summary report: N

EVOLUTION® NITRX? TIB KEELED

MDR report key: 15744754 · Received November 7, 2022

Report

Report Number
3010536692-2022-00404
Event Type
Injury
Date Received
November 7, 2022
Date of Event
September 25, 2022
Report Date
January 18, 2023
Manufacturer
MICROPORT ORTHOPEDICS INC.
Product Code
JWH
UDI-DI
M684ETAKN6SL1
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
ID, US
Reporter Occupation
OTHER HEALTH CARE PROFESSIONAL
Health Professional
Yes

Narratives

Additional Manufacturer Narrative · 0

THIS EVENT WILL BE UPDATED ONCE THE INVESTIGATION IS COMPLETE. TRENDS WILL BE EVALUATED.

Description of Event or Problem · 0

ALLEGEDLY, REPORTER BECAME AWARE OF SOME NITRX COMPLAINTS FROM A SURGEON IN IDAHO HOWEVER, NO INFORMATION ABOUT THE COMPLAINTS WERE GIVEN TO REPORTER. MICROPORT ORTHOPEDICS VP R&D PROD. DEVELOPMENT STATED THAT HE RECEIVED A PHONE CALL FROM (B)(6)(SALES REP) SAYING THAT A DOC IN IDAHO HAD A FEW PATIENTS COME BACK IN WITH PAINFUL, SWOLLEN KNEES. HE CONTACTED THE REP TO SEE IF HE COULD GET MORE DETAILS. HE ASKED A SERIES OF QUESTIONS THAT HE DID NOT KNOW THE ANSWER. NO PART/LOT NUMBERS ARE GIVEN AND IT HAS NOT BEEN INDICATED HOW MANY EVENTS/PATIENTS HAVE OCCURRED REGARDING THESE ISSUES. ADDITIONAL INFORMATION RECEIVED ON 10/05/2022: A TOTAL OF 8 COMPLAINTS WERE RECEIVED WITH ALL RELEVANT INFORMATION INCLUDED IN EACH INCIDENT FORM. THE 7 REMAINING COMPLAINTS ARE CAPTURED UNDER DIFFERENT MICROPORT INCIDENT GROUP NUMBERS. ALLEGEDLY, RECURRING KNEE EFFUSION. NO INFECTION TO DATE. IT WAS CONFIRMED THAT EACH OF THESE PATIENTS WERE SEEN FOR FOLLOW-UP APPOINTMENTS TO ADDRESS INFLAMMATION IN THEIR KNEES. THE SURGEON CONFIRMED THAT NONE OF THE PATIENTS HAD INFECTIONS AND THAT THEIR KNEES HAD FLUID BUILDUP THAT WAS DRAINED. THE SURGEON HAS NOT BEEN ABLE TO DETERMINE IF THESE EVENTS WERE CAUSED BY AN ALLEGED DEFICIENCY/FAILURE AGAINST THESE DEVICES OR IF THEY WERE CAUSED DUE TO PATIENT CONDITIONS. IT IS INDICATED THAT THERE IS NO ACCESS TO INFORMATION REGARDING EACH PATIENT'S CONDITION, ACTIVITY LEVEL, MEDICAL HISTORY, ETC. INCIDENT FORM RECEIVED CONTAINS TWO EVOLUTION® MP CS INSERTS HOWEVER ONLY ONE INSERT (EIS6S12L) IS INDICATED AS A REVISED COMPONENT. THE OTHER INSERT MENTIONED IN THE INCIDENT FORM IS: EIS6S14L,EVOLUTION® MP? CS INSERT SIZE 6 STANDARD 14MM LEFT,LOT:1826291,QTY1. ALSO, THERE HAS BEEN AN INSTRUMENT (K0001288, ADVANCE® EVOLUTION® PIN PACK 3 LONG & 2 COLLARED STERILE, LOT:1878974) INDICATED ON THE INCIDENT FORM RECEIVED, HOWEVER THERE IS NO COMPLAINT STATED AGAINST THIS INSTRUMENT.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
2839329 EVOLUTION® NITRX? TIB KEELED KNEE COMPONENT JWH MICROPORT ORTHOPEDICS INC. ETAKN6SL 1850585 M684ETAKN6SL1

Patients

Seq Age Sex Outcome Treatment
1 63 YR Male Required Intervention