FDA Adverse Event Injury Summary report: N

UNKNOWN KNEE FEMORAL

MDR report key: 13591023 · Received February 24, 2022

Report

Report Number
1818910-2022-03446
Event Type
Injury
Date Received
February 24, 2022
Date of Event
January 1, 2022
Report Date
February 24, 2022
Manufacturer
DEPUY ORTHOPAEDICS INC US
Product Code
JWH
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
IN
Reporter Occupation
OTHER HEALTH CARE PROFESSIONAL
Health Professional
Yes

Narratives

Additional Manufacturer Narrative · 0

PRODUCT COMPLAINT # (B)(4). IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL MEDWATCH, A FOLLOW-UP MEDWATCH WILL BE FILED AS APPROPRIATE.

Additional Manufacturer Narrative · 0

PRODUCT COMPLAINT # (B)(4). IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL MEDWATCH, A FOLLOW-UP MEDWATCH WILL BE FILED AS APPROPRIATE.

Additional Manufacturer Narrative · 0

PRODUCT COMPLAINT (B)(4). INVESTIGATION SUMMARY: THE DEVICE ASSOCIATED WITH THIS REPORTED EVENT WAS NOT RETURNED. AVAILABLE XRAY EVIDENCE INCLUDED IN THE STUDY WAS REVIEWED. NO FAILURE OF ANY DEPUY PRODUCT CAN BE OBSERVED. DEPUY CONSIDERS THE INVESTIGATION CLOSED. SHOULD ADDITIONAL INFORMATION BE RECEIVED, THE INFORMATION WILL BE REVIEWED. AND THE INVESTIGATION WILL BE RE-OPENED AS NECESSARY. DEVICE HISTORY LOT: A MANUFACTURING RECORDS EVALUATION (MRE) WAS NOT PERFORMED, AS NO LOT NUMBER WAS PROVIDED FOR THIS DEVICE.

Description of Event or Problem · 0

LITERATURE ARTICLE ENTITLED ¿NOTCHING IS LESS, IF FEMORAL COMPONENT SAGITTAL POSITIONING IS PLANNED PERPENDICULAR TO DISTAL FEMUR ANTERIOR CORTEX AXIS, IN NAVIGATED TKA.¿ KANNA R, RAVICHANDRAN C, SHETTY GM. KNEE SURG RELAT RES. 2021 DEC 24;33(1):46. DOI: 10.1186/S43019-021-00129-9. PMID: 34952652; PMCID: PMC8709981. THE ARTICLE'S PURPOSE WAS TO DETERMINE IF, BY OPTING TO PLACE THE FEMORAL COMPONENT PERPENDICULAR TO DISTAL FEMUR ANTERIOR CORTEX AXIS (DCX), NOTCHING CAN BE REDUCED IN NAVIGATED TKA. PATIENT DATA: 171 PATIENTS WERE AVAILABLE FOR ANALYSIS WITH BILATERAL KNEES. MEAN AGE OF PATIENTS AT THE TIME OF SURGERY WAS 66.5±8.5 YEARS (RANGE 44¿89 YEARS). THERE WERE 60 (35.1%) MALE AND 111 (64.9%) FEMALE PATIENTS. MEAN BODY MASS INDEX WAS 29±4 KG/M2. IT IS NOTED THAT CONSTRUCTS IN THE STUDY WERE CEMENTED (UNKNOWN CEMENT MANUFACTURER) AND HAD PATELLA IMPLANTS. DEPUY PRODUCTS: P.F.C. SIGMA CONSTRUCT AND ATTUNE CONSTRUCT. THE ADVERSE EVENTS PROVIDED DID NOT SPECIFY WHAT TYPE OF CONSTRUCT WAS INVOLVED WITH THE BONE FRACTURE OR INFECTION. PAIN AND NOTCHING OCCURRED IN BOTH THE ATTUNE AND SIGMA KNEES. ADVERSE EVENTS (PATIENT SPECIFIC EVENTS WERE NOT SPECIFIED). FEMORAL BONE NOTCHING (46 TOTAL OCCURRENCES) - TREATMENT NOT SPECIFIED. PAIN (19 TOTAL OCCURRENCES) - TREATMENT NOT SPECIFIED . POST OP SUPRA-CONDYLAR BONE FRACTURE (1 OCCURRENCE) - OPEN REDUCTION AND INTERNAL FIXATION. POST OP INFECTION (1 OCCURRENCE) ¿ IRRIGATION AND DEBRIDEMENT PLUS POLY INSERT EXCHANGE.

Description of Event or Problem · 0

LITERATURE ARTICLE ENTITLED ¿NOTCHING IS LESS, IF FEMORAL COMPONENT SAGITTAL POSITIONING IS PLANNED PERPENDICULAR TO DISTAL FEMUR ANTERIOR CORTEX AXIS, IN NAVIGATED TKA.¿ KANNA R, RAVICHANDRAN C, SHETTY GM. KNEE SURG RELAT RES. 2021 DEC 24;33(1):46. DOI: 10.1186/S43019-021-00129-9. PMID: 34952652; PMCID: PMC8709981. THE ARTICLE'S PURPOSE WAS TO DETERMINE IF, BY OPTING TO PLACE THE FEMORAL COMPONENT PERPENDICULAR TO DISTAL FEMUR ANTERIOR CORTEX AXIS (DCX), NOTCHING CAN BE REDUCED IN NAVIGATED TKA. PATIENT DATA: 171 PATIENTS WERE AVAILABLE FOR ANALYSIS WITH BILATERAL KNEES. MEAN AGE OF PATIENTS AT THE TIME OF SURGERY WAS 66.5±8.5 YEARS (RANGE 44¿89 YEARS). THERE WERE 60 (35.1%) MALE AND 111 (64.9%) FEMALE PATIENTS. MEAN BODY MASS INDEX WAS 29±4 KG/M2. IT IS NOTED THAT CONSTRUCTS IN THE STUDY WERE CEMENTED (UNKNOWN CEMENT MANUFACTURER) AND HAD PATELLA IMPLANTS. DEPUY PRODUCTS: P.F.C. SIGMA CONSTRUCT AND ATTUNE CONSTRUCT. THE ADVERSE EVENTS PROVIDED DID NOT SPECIFY WHAT TYPE OF CONSTRUCT WAS INVOLVED WITH THE BONE FRACTURE OR INFECTION. PAIN AND NOTCHING OCCURRED IN BOTH THE ATTUNE AND SIGMA KNEES. ADVERSE EVENTS (PATIENT SPECIFIC EVENTS WERE NOT SPECIFIED). FEMORAL BONE NOTCHING (46 TOTAL OCCURRENCES) - TREATMENT NOT SPECIFIED. PAIN (19 TOTAL OCCURRENCES) - TREATMENT NOT SPECIFIED . POST OP SUPRA-CONDYLAR BONE FRACTURE (1 OCCURRENCE) - OPEN REDUCTION AND INTERNAL FIXATION. POST OP INFECTION (1 OCCURRENCE) ¿ IRRIGATION AND DEBRIDEMENT PLUS POLY INSERT EXCHANGE.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
107151 UNKNOWN KNEE FEMORAL KNEE FEMORAL JWH DEPUY ORTHOPAEDICS INC US

Patients

Seq Age Sex Outcome Treatment
1 Unknown Required Intervention