15 results
·
20ms
·
Sources: EU EUDAMED, US FDA
LIFESTENT LP SDS BILIARY ENDOPROSTHESIS
FDA 510(k)
FDA Class 2
·Gastroenterology, Urology
Green X-ray Film WB
FDA UDI
CARESTREAM HEALTH, INC.·60889976041376·25SH 14X36IN (FLAT) GREEN X-RAY WB
NOBELACTIVE INTERNAL NP 3.5X11.5MM
FDA Adverse Event
Injury
·NOBEL BIOCARE AB·Product code DZE·August 13, 2020
NOBELACTIVE INTERNAL RP 4.3X10MM
FDA Adverse Event
Injury
·NOBEL BIOCARE USA INC·Product code DZE·September 8, 2020
NOBELACTIVE INTERNAL NP 3.5X11.5MM
FDA Adverse Event
Injury
·NOBEL BIOCARE AB·Product code DZE·August 13, 2020
ACCUSONIC PLUS, MODEL AP-100
FDA 510(k)
FDA Class 2
·Physical Medicine
NON-STERILE POWDER FREE PURPLE LATEX EXAMINATION GLOVE WITH AND WITHOUT GRAPE SCENT AND WITH PROTEIN LABELING (50 MICROG
FDA 510(k)
FDA Class 1
·General Hospital
PFC SIGMARP STB TB IN 4 12.5
FDA Adverse Event
Injury
·DEPUY (IRELAND) 9616671·Product code NJL·April 8, 2013
9900
FDA Adverse Event
Malfunction
·GE OEC MEDICAL SYSTEMS (SLC)·Product code JAA·March 23, 2011
FREESTYLE FREEDOM
FDA Adverse Event
Malfunction
·ABBOTT DIABETES CARE INC., USA·Product code LFR·May 15, 2008
Medfusion Syringe Pump, Model 4000. The Model 4000 pump is a small, lightweight and portable syringe infusion pump. The pump offers a variety of delivery modes programmable to meet specific patient care needs.
FDA Enforcement
Class I
·Terminated·Smiths Medical ASD Inc.·December 18, 2019
Advantage Workstation Volume Share 2 (versionAW4.4_04) with Volume Viewer 3 and 3.1 (version7.0 to version7.5 and version 8.1) and only when or more of these applications is installed: " VesselIQ Xpress or AVA Xpress " CardIQ Xpress Pro or Plus " CardEP " CardIQ Fusion PET or SPECT Advantage Workstations Volume Share (v.AW4.3) and AW4.2 (version4.2-05 and above) provided with Volume Viewer 2(version6.0 to version6.11) and only when one or both of these applications is installed: " CardIQ Xpress Pro or Plus " CardEP Advantage Workstations AW Volume Share 2 (AW version 4.4). ONLY IF ONE OF FOLLOWING APPLICATIONS IS INSTALLED: VesselIQ Xpress or AVA Xpress CardIQ Xpress Pro or Plus CardEP CardIQ Fusion PET or SPECT provided with Volume Viewer 3 and 3.1 from versions 7.0 to 7.5 and 8.1. To verify the version installed on your system: Select the Admin menu from the Patient list page. Then select Display Configuration. You will find the version of your system in Installed Application(s). This version will appear as vxtl_7.x or vxtl_8.x. Intended use: K993792: Smart Vessel Analysis (Smart VA) is a software post-processing option for the Advantage Workstation (AW) platform, which can be used in the analysis of 3D angiography data. It provides a number of display, measurement and batch filming/archive features and will aid physicians in studying user-selected vessels for stenosis analysis, pre/post stent planning and directional vessel tortuosity visualization. K031261: Card EP is a post processing software option for the Advantage Workstation (AW) Platform. This product can be used for the analysis of CT angiographic images for the assessment of the heart to include the atria, pulmonary veins, and coronary sinus. It provides quantitative analysis tools which include a number of display, measurement and model export capabilities. This product can be used to aid trained physicians in the visualization and assessment of cardiac anatomy. K041267: CardIQ Analysis III is a CT image analysis software package, which allows the visualization of 2D and 3D medical image data of the heart derived from DICOM 3.0 compliant CT scans for the purpose of cardiovascular disease assessment. It provides functionally for 2D/3D rendering, assessment of calcified and non-calcified plaque to determine the densities of the plaque within a coronary artery, ventricular function of the heart, and measurement tools to detect coronary artery stenosis. This product can be used to aid a trained physician to process, render, review, archive, print and visualizing cardiac anatomy and coronary vessels. CardIQ Analysis II will run on the AW workstation, scanner operator console and PACS system. K061370: CardIQ Fusion is intended to provide an optimized non-invasive application to analyze vascular anatomy and pathology, aid in the assessment of functional data e.g. PET perfusion, and aid in tailoring treatment plans based on the fused anatomical and functional information. Anatomical data could be from a set of Computed Tomography (CT) Angiographic images while functional data could be from PET, SPECT, or processed CT data. CardIQ Fusion is a software post-processing package for the Advantage Workstation (AW) platform, PET/CT and CT scanners and PACS reading stations. It is an additional tool for the analysis of 3D CT angiographic cardiac images/data providing a number of display, measurements and batch filming/archive features to study user-selected vessels. Also included is the capability to visualize reformatted CT/PET/SPECT perfusion and viability data. Finally, it provides different ways of visualizing CT anatomy fused with PET/SPECT functional information. With CardIQ Fusion, clinicians have the opportunity to overlay functional information over the (CT) anatomy of a patient's heart, and thus, they can potentially tailor their decision for that particular patient. CardIQ Fusion provides the visualization of the vessels in severa
FDA Recall
Terminated
·GE Healthcare, LLC·Product code LLZ·May 29, 2012
Advantage Workstation Volume Share 2 (versionAW4.4_04) with Volume Viewer 3 and 3.1 (version7.0 to version7.5 and version 8.1) and only when or more of these applications is installed: " VesselIQ Xpress or AVA Xpress " CardIQ Xpress Pro or Plus " CardEP " CardIQ Fusion PET or SPECT Advantage Workstations Volume Share (v.AW4.3) and AW4.2 (version4.2-05 and above) provided with Volume Viewer 2(version6.0 to version6.11) and only when one or both of these applications is installed: " CardIQ Xpress Pro or Plus " CardEP Advantage Workstations AW Volume Share 2 (AW version 4.4). ONLY IF ONE OF FOLLOWING APPLICATIONS IS INSTALLED: ¿ VesselIQ Xpress or AVA Xpress ¿ CardIQ Xpress Pro or Plus ¿ CardEP ¿ CardIQ Fusion PET or SPECT provided with Volume Viewer 3 and 3.1 from versions 7.0 to 7.5 and 8.1. To verify the version installed on your system: Select the Admin menu from the Patient list page. Then select Display Configuration. You will find the version of your system in Installed Application(s). This version will appear as vxtl_7.x or vxtl_8.x. Intended use: K993792: Smart Vessel Analysis (Smart VA) is a software post-processing option for the Advantage Workstation (AW) platform, which can be used in the analysis of 3D angiography data. It provides a number of display, measurement and batch filming/archive features and will aid physicians in studying user-selected vessels for stenosis analysis, pre/post stent planning and directional vessel tortuosity visualization. K031261: Card EP is a post processing software option for the Advantage Workstation (AW) Platform. This product can be used for the analysis of CT angiographic images for the assessment of the heart to include the atria, pulmonary veins, and coronary sinus. It provides quantitative analysis tools which include a number of display, measurement and model export capabilities. This product can be used to aid trained physicians in the visualization and assessment of cardiac anatomy. K041267: CardIQ Analysis III is a CT image analysis software package, which allows the visualization of 2D and 3D medical image data of the heart derived from DICOM 3.0 compliant CT scans for the purpose of cardiovascular disease assessment. It provides functionally for 2D/3D rendering, assessment of calcified and non-calcified plaque to determine the densities of the plaque within a coronary artery, ventricular function of the heart, and measurement tools to detect coronary artery stenosis. This product can be used to aid a trained physician to process, render, review, archive, print and visualizing cardiac anatomy and coronary vessels. CardIQ Analysis II will run on the AW workstation, scanner operator console and PACS system. K061370: CardIQ Fusion is intended to provide an optimized non-invasive application to analyze vascular anatomy and pathology, aid in the assessment of functional data e.g. PET perfusion, and aid in tailoring treatment plans based on the fused anatomical and functional information. Anatomical data could be from a set of Computed Tomography (CT) Angiographic images while functional data could be from PET, SPECT, or processed CT data. CardIQ Fusion is a software post-processing package for the Advantage Workstation (AW) platform, PET/CT and CT scanners and PACS reading stations. It is an additional tool for the analysis of 3D CT angiographic cardiac images/data providing a number of display, measurements and batch filming/archive features to study user-selected vessels. Also included is the capability to visualize reformatted CT/PET/SPECT perfusion and viability data. Finally, it provides different ways of visualizing CT anatomy fused with PET/SPECT functional information. With CardIQ Fusion, clinicians have the opportunity to overlay functional information over the (CT) anatomy of a patient's heart, and thus, they can potentially tailor their decision for that particular patient. CardIQ Fusion provides the visualization of the vessels in severa
FDA Enforcement
Class II
·Terminated·GE Healthcare, LLC·December 26, 2012
Brand Name: Da Vinci 5 Product Name: ASSY,DV5 TOWER,IS5000 Model/Catalog Number: 380746 Software Version: N/A Product Description: Preface: This report under 21 CFR 806.10 is being submitted for the dV5 system tower, as the NIR Handheld Camera or SOCK is developed and integrated as part of the dV5 system. The affected component of the dV5 system tower is the NIR handheld camera, and is supplied by Schoelly as the manufacturer. Therefore, the product description in this report references the NIR handheld camera system. Product Description: The NIR handheld camera system is compatible for use with the da Vinci¿ 5 system to aid in surgery. The components of the NIR handheld camera system include a camera control unit and a light source, NIR handheld camera, and additional components that together, connect to the Tower of the da Vinci 5 system. When setting up the da Vinci 5 system, the image from the NIR handheld camera system is displayed on the Tower monitor. Component: Yes, the SOCK is the component and integrated into the dV5 system
FDA Enforcement
Class II
·Ongoing·Intuitive Surgical, Inc.·June 10, 2026
Ellipse, Sterile EO, Model #/ Part #: CD1275-36/100116115; CD1275-36Q/100116116; CD1277-36/100048388, 100048391, 100060126, 100116208, 10011636; CD1277-36Q/100048374, 100048394, 100060198, 100098497, 100116268, 100116345; CD1293-36Q/100057838; CD1309-36/100057717; CD1309-36Q/100057718; CD1311-36/100057802, 100060153; CD1311-36Q/100057803, 100060174, 100116264; CD1377-36/100078796, 100079180, 100096847; CD1377-36C/100078612, 100079197, 100079368, 100116120, 100116407, 100116447; CD1377-36Q/100078747, 100079210, 100096848, 100116385, 100116423, 100116427; CD1377-36QC/100078602, 100079199, 100079229, 100116398, 100116409, 100116466,100116485, 100127151, 100127152, 100127153; CD1393-36C/100116461; CD1393-36QC/100080656, 100116339; CD1409-36Q/100080251; CD1411-36C/100080197, 100080232, 100116411, 100116481; CD1411-36Q/100080244, 100080245, 100116338, 100116464; CD1411-36QC/100116337; CD2275-36/100116355; CD2275-36Q/100116349; CD2277-36/100048359, 100048402, 100116206, 100116207; CD2277-36Q/100048377, 100048404,100060190, 100098661, 100116342, 100116350; CD2293-36/100057765; CD2293-36Q/100057766; CD2309-36/100057804; CD2309-36Q/100057763; CD2311-36/100057679, 100060100; CD2311-36Q/100057835, 100060161, 100116351; CD2377-36/100078811, 100079226, 100096774; CD2377-36C/100078601,100079225, 100079304, 100116405, 100116424, 100116484; CD2377-36Q/100078812,100079208, 100096838, 100116406, 100116414, 100116437; CD2377-36QC/100078579, 100079176, 100079352, 100116413, 100116422, 100116436, 100116482, 100127100, 100127154, 100127181; CD2393-36C/100080653, 100116416; CD2393-36QC/100080655, 100116451; CD2409-36C/100079997; CD2409-36Q/100080149; CD2411-36C/100079986, 100080104, 100116118, 100116444; CD2411-36Q/100080180, 100080230, 100116370, 100116420
FDA Enforcement
Class II
·Terminated·St Jude Medical Inc.·July 4, 2018